2 inputs for Strain Gauge, 1 x excitation output, 1 x digital in, 4 x digital out, RS485 bus, Display.

RS485 Module for load cells
2 analog inputs for 4 wire load cell,
1 excitation Exit
1 Digital input
4 digital outputs
Supply: 10 - 30VDC

M485-AD16DA12-ID
1,200.00 DKK
Tax excluded
Quantity
Physically in stock  

  • Download PDF
  • file_download Downloads
  • live_help Ask a question

In the industrial environment, there are many examples where force is to be converted to a measurable electrical output.

In most cases, a strain gauge bar meter in a load cell is used. But the question is, how should we handle these electrical output measurements? In this situation, the M485-AD16DA12 ID certainly is the best choice. Not only can the module process data from a load cell or bar meter, it also has linear mapping that can be used to directly convert the resulting data to weight via a custom correspondent table. M485-AD16DA12 ID supports full-bridge voltage meters and provides 2 analog input channels, 1 excitation voltage output channel, 1 digital input channels and 4 digital output channels. The module has a programmable input range (± 15 mV, ± 50 mV, ± 100 mV, ± 500 mV, ± 1 V and ± 2.5 V), and each analog input channel can be configured individually. Excitation voltage output may be in the range 0 ~ +10 V with a driving efficiency of 40 mA. Digital output channels can also be set as high or low alarm outputs.

Forsyning
10 - 30 VDC, 2,2 W via klemrække
Indgangsimpedans
2 MΩ
Isolation
3000 VDC
Maks. hastighed
10 pr. sek.
Opløsning
16 bit, ±0,05 % præcision
Skærm
4½ ciffer display
Stabilitet
Nulpunktsdrift: ±0,6 µV/°C Drift af følsomhed: ±25 ppm/°C
Udgange
4 stk. “Open collector”: 30 VDC, 30 mA
Udgange