Multi-Network Output Module with Galvanic I / O
10/100 Mbit Ethernet Connection
Password Protected WEB Server
2 Analog Outputs with Voltage and Power Generator
0 - 20mA, 4 - 20mA, 0 - 24mA
0 - 5V or 0 - 10V voltage output
4 digital (open drain) outputs with ON / OFF or PWM
2 relays with COM, NO and NC contacts
4 scheduled actions, 1 time or weekly
NTP, SNMP v2, SNMP trap for up to 5 recipients
MODBUS TCP / IP
HTTP upload with current status in XML or JSON remote server file
HTTP API commands in server and client mode
HTTP Post can be sent to 3 servers
DIN rail / wall mounting
Supply voltage: 10 - 32VDC / max 250mA
Multi input data logging for up to 70000 login
10/100 Mbit Ethernet
Password protected, web-based configuration and control
4 digital inputs, compatible with S0 pulse interface
6 analog inputs with 0 / 10V and 0 / 20ma
Modbus RTU interface for up to 24 sensors (registers)
Up to 24 channels for monitoring
Up to 24 Independent Alarms
SNMP V.2 Support - SNMP Trap - Alarm Alerts
HTTP and SNMP port change - HTTP API commands
Periodic HTTP post of XML / JSON Status files for client server systems
Modbus TCP / IP support
Dynamic DNS with dynns, no- IP and DNS-O-MATIC Support
NTP protocol support
supply voltage: 10 to 32V DC
Smoke alarm with a diameter of 15 meters installation up to 11 meters high With potential-free relay contact Smoke sensitivity: EN 54-7:2000+ A1:2002 Operating temperature: -10 to +55 °C Dimensions: Ø100 mm, h 47 mm Weight: 100 g
Get your free license key from Teracom
DAQ software for Teracom Ethernet-based measuring devices
User-friendly WEB interface for easy configuration and control
Flexible user access and management
Distributed monitoring units in "client" fashion
Alarm notification
Activity log
Graphics and data display with large visualization
Easy access to raw data, tables, export in CSV format (comma separated)
Database management
Send command to check in "server" and "client" mode
command status log
Remote collection of data, remote meter monitoring, energy management
Energy Meter Interface Module with MODBUS RTU
RS-485 interface with up to 63 units per BUS
Built-in 120 ohm termination resistor
Flash memory data and setup
Power supply from 5 to 32VDC, 25mA at 5VDC
Galvanic isolated digital input - 10mS pollinghastighed
Optional inputs: Open / Closed (dry contact and 32 bit counter)
S0 pulse counter applications :
Remote monitoring of electricity meters
Industrial process control
Remote monitoring of gas meters and water meters
monitoring devices with S0 outputs;
process monitoring
DIN rail mounting
Firmware update via interface.
Dim: 35 x 86 x 59 mm
Multi-band 4G LTE Cat.1 controller, logger and alarm Setup via USB, SMS and HTTP API USB setup - use USB cable with Mini B male 2 digital "dry contacts". High on contact 2 analog inputs, 0 - 10VDC or 4-20mA input (10bit) 4 relay outputs, COM, NO and NC 1-Wire input for up to 8 Teracom sensors 1 x RS485 for max. 8 MODBUS RTU sensors Data logger with 70,000 logs Upload data to HTTP/HTTPS Post in XML/JSON SMS alarm and Email alarm to 5 recipients Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup. 10 to 28VDC, 370mA @ 12VDC - additional PSU Dimensions: 158 x 119 x 34 mm Weight: 470g Temperature: -20 - +55°C
1-wire Combi Sensor
Temperature: -20 - +60 ° C +/- 0.6 ° C
Resolution: 0.1 ° C
Humidity (Moisture): 5 -95% Rh +/- 5%
Resolution 0.1%Rh
IP54 Plastic housing, very sturdy
Up to 8 sensors on the same 1-wire
16 bits at temperature
12 bits at moisture
Supply Voltage: 4.5 / 25mW
Dimensions: 74 x 66 x 36 mm
1-wire lysmåler til synligt lys
0 - 83.000lux med 1 lux opløsning
Op til 23bit opløsning
Automatisk fuld skala justering
Kan kaskadekoples via RJ11 stik
Forsynes fra Controller med 5VDC/4mA
Maks. 30 meter kabel
Mål: 85 x 35 x 24 mm
IP30 plasthus med flange
GSM / LTE alarm - 4G Configuration via USB (Windows program) or SMS 2 x digital inputs with "dry contact" or "logic level" mode 2 x analog input from 0 to 60VDC, 10 bits 2 x relay output with NO / NC switches 1-Wire interface for 4 Teracom temperature and humidity sensors Input can be navigated with alarm text etc. SMS alarm - up to 5 numbers Email alarm - up to 5 email recipients, SMTP with TLS support 1 relay can be activated with calls from up to 100 telephone numbers Push mode - XML data is sent via HTTP Post to a remote server. Server response may include relay setup. MQTT 3.1.1 support Firmware update "on air" Supply voltage: 8 - 32VDC, 2Watt - additional PSU Dimensions: 109 x 65 x 32 mm Weight: 152g
Multisensor for CO2 and barometric pressure Interface: 1-wire (+/- and data) LED indicator for communication status Long-term stability based on digital signal processing Self-calibration on fresh air for CO2 measurements Interchangeable communication parameters Non-volatile memory for all settings Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g Supply voltage: 4.5 - 26VDC / Max. 150mA
Multi sensor for CO2 and Barometric pressure Interface: RS485 - MODBUS RTU LED indicator for status of communication Long-term stability based on digital signal processing Self-calibration on fresh air for CO2 measurements Changeable communication parameters Non-volatile memory for all settings Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g Supply voltage: 4,5 - 26VDC / Max. 150mA
Temperature and humidity sensor 1-wire interface for Teracom controller Temperature: +/-0.4 °C (-10 to +60 °C), max. +/-0.6°C Resolution: 0.1°C Humidity: +/-3.0% RH (20 - 80% RH), max. +/-5% relative humidity Solution: 0.1% RH Supply voltage: 4.5 - 26VDC LED indicator for communication status Long-term stability based on digital signal processing Changeable bit rate and other communication parameters Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g
Temperature and Humidity sensor RS485 MODBUS RTU Temperature: +/-0,4 °C (-10 to +60°C), max. +/-0,6°C Resolution: 0,1°C Humidity: +/-3,0% RH (20 - 80% RH), max. +/-5% RH Resolution: 0,1% RH Supply voltage: 4,5 - 26VDC LED indicator for status of communication Long-term stability based on digital signal processing RS-485 interface (2-wire) carrying up to 32 nodes Changeable bitrate and other communication parameters Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g
Multi sensor for CO2, Temperature and Humidity Interface: RS485 - MODBUS RTU LED indicator for status of communication Long-term stability based on digital signal processing Self-calibration on fresh air for CO2 measurements Changeable communication parameters Non-volatile memory for all settings Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g Supply voltage: 4,5 - 26VDC / Max. 150mA
Web based Data collector module with built-in WebServer Supports MQTT 3.1.1 protocol 4 x digital input Dry - external contact without voltage 4 x analogue inputs with 0 to 10VDC, 0-20mA 4 x powerful relay outputs with NO/NC contacts RS485 port MODBUS RTU up to 24 registers (sensors) Modbus TCP/IP support Data logger with memory for 70,000 logs SNMP v3 support with trap alarm 4 pcs. schemes for real-time control of relay Up to 24 independent alarms Secure email XML/JSON and HTTP API commands for client-server Dynamic DNS support for DynDNS, No-IP and DNS-O-Matic NTP time sync Supply voltage: 10 - 32VDC - purchase PSU Dimensions: 145 x 90 x 40 mm
1-wire Temperature / Humidity sensor Temperature -20 - +60°C Humidity 10 - 90% RH Temp tolerance +/-0.4°C at -10 - +60°C Moisture tolerance ±3.0%rH at 20 - 80%rH Long term operation ±0.25%/year at 20 to 80%rH Long-term operation ±0.05°C/year at -10 to +60°C Solution 0.1 %rH 0.1 °C Power supply/consumption 4.0 to 5.5 VDC 5 mA Dimensions 62 x 28 x 16 mm Cable length 1 m
1-wire temperature and humidity meter 12 bit resolution when measuring moisture 14 bit resolution when measuring temperature Good long-term stability LED communication indicator Dimensions: 99 x 66 x 36 mm Weight: 70g
GSM/LTE alarm - 4G - Global version Supports all LTE frequencies Configuration via USB (Windows program) or SMS 2 x digital inputs with "dry contact" or "logic level" mode 2 x analogue input from 0 to 60VDC, 10 bits 2 x relay output with NO/NC contacts 1-Wire interface for 4 Teracom temperature and humidity sensors Input can be navigated with alarm text etc. SMS alarm - up to 5 numbers Email alarm - up to 5 email recipients, SMTP with TLS support 1 relay can be activated with calls from up to 100 phone numbers Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup. MQTT 3.1.1 support Firmware update "on air" Supply voltage: 8 - 32VDC, 2Watt - purchase PSU Dimensions: 109 x 65 x 32 mm Weight: 152g
Global 4G LTE Controller, logger and alarm Supports all LTE frequencies Setup via USB, SMS and HTTP API USB setup - use USB cable with Mini B male 2 digital "dry contacts". High on contact 2 analog inputs, 0 - 10VDC or 4-20mA input (10bit) 4 relay outputs, COM, NO and NC 1-Wire input for up to 8 Teracom sensors 1 x RS485 for max. 8 MODBUS RTU sensors Data logger with 70,000 logs Upload data to HTTP/HTTPS Post in XML/JSON SMS alarm and Email alarm to 5 recipients Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup. 10 to 28VDC, 370mA @ 12VDC - additional PSU Dimensions: 158 x 119 x 34 mm Weight: 470g Temperature: -20 - +55°C