Open board til smart temperatur- eller fugt måling and styring
Password beskyttet Web baseret konfiguration og kontrol
1 x digital input med “dry contact” og “logic level” mode
1 x analog input fra 0 til 60VDC
1 relæ output med NO/NC kontakter
1-Wire input til 1 temperature eller fugtmåler
SNMP v.1 support
SNMP traps ved alarm
E-mail udsendelse ved alarm
SMTP med godkendelse (SSL/TLS er ikke supporteret)
HTTP og XML API kommandoer
Remote FTP firmware update.
Module with smart temperature and moisture measurement and control
Password protected Web based configuration and control
1-Wire interface for 2 temperature sensors
2 x analog inputs from 0 to 60VDC - 10bit resolution, 100mV display
2 x digital inputs with "dry contact" and "logic level" mode
2 x relay output with NO / NC contacts
E-mail broadcast by alarm
SMTP with authentication (SSL / TLS is not supported)
SNMP v.1
SNMP traps generated alarm for HTTP and XML API commands
Remote firmware update.
Module with password protected Web based configuration and control
1-Wire interface for 2 sensors
2 x relay outputs with NO / NC contacts
2 x analog input with 0 to 60VDC
2x digital input with "dry contact" or "logic level" mode
Stable IP watchdog monitoring - for restarting equipment
SNMP v.1 support
SNMP trap conditional messages
VLAN and MAC address filtering
Remote FTP firmware update.
12VDC - purchase PSU
Stand-alone Data logger via Ethernet Memory for 70,000 measurements Can be programmed to log every 3 seconds Password protected Web based configuration and control 2 x digital input "dry contact" 2 x analog inputs 0 to 10VDC, 10-bit resolution, 10mV display Multiply and offset for analog input 2 x relay with NO/NC contacts 1-Wire interface for 8 sensors SNMP v.2 support SNMP traps up to 5 alarm types MODBUS TCP/IP support E-mail to 5 recipients in case of conditional alarm HTTP API commands NTP and dynamic DNS support Remote firmware update Supply voltage: 10 - 32VDC - purchase PSU
Web based data collector module with built-in Web server
4 x digital input dry - External contact without voltage
4 x analog inputs with 0 to 60vdc - 10mv resolution
multiplier and offset for analog inputs and sensors
1-wire for a maximum of 8 sensors (16 parameters)
4 x Powerful relay outputs with No / NC Contacts
Modbus TCP / IP Support
SNMP V2 Support with Trap Alarm for 5 Recipients
4 PCS. Forms for real-time control of relay
Specific logical functions for relays
Secured email
XML / JSON and HTTP API commands for Client server
Dynamic DNS support for Dyndns, No-IP and DNS- O-Matic
NTP TimeSync
Supply voltage: 10 - 32VDC - Buy PSU
Dim: 145 x 90 x 40 mm
Data logger for external temperature and humidity sensors Sensors are not included - must be purchased separately, see selection Memory for 70,000 measurements Temperature, humidity and dew point can be displayed graphically 1-Wire and RS485 sensor interface Up to 8 Teracom sensors can be connected MODBUS TCP/IP support SNMP v2 with trap alarm for 5 email recipients Secure email XML/JSON and HTTP API commands for client-server Dynamic DNS, DynDNS, No-IP and DNS-O-Matic NTP support for time synchronization Remote firmware update Supply voltage: 10 - 32VDC - purchase PSU
GSM alarm - 2G Configuration via USB (Windows program) or SMS 2 x digital inputs with "dry contact" or "logic level" mode 2 x analog input from 0 to 60VDC 2 x relay output with NO / NC switches 1-Wire interface for 4 Teracom temperature and humidity sensors Input from devices can be navigated with alarm text etc. SMS alarm - up to 5 numbers Email alarm - up to 5 email recipients, SMTP with TLS support 1 relay can be activated with calls from up to 100 telephone numbers Push mode - XML data is sent via HTTP Post to a remote server. Server response may include relay setup. Firmware update "on air" Supply voltage: 8 - 32VDC, 2Watt - additional PSU Dimensions: 107 x 72 x 32 mm Weight: 130g
Temperature sensor with Dallas chip - up to 8 pieces on the same bus
1-wire communication to the measuring electronics
± 0.5 ° C accuracy from -10 ° C to + 85 ° C
12 bit resolution
Aluminum head provides low thermal resistance
IP65 close
Very low power consumption
Each unit has a unique 64 bit serial number
Temperature sensor with Dallas chip - up to 8 pieces on the same bus 1-wire communication to the measuring electronics With connector for cascade coupling to the next sensor ±0.5°C accuracy from -40°C to +85°C 12 bit resolution Temperature sensor in the box Very low power consumption Each device has a unique 64 bit serial number
1-wire communications - several sensors can be connected to the same unit
± 3.0% relative humidity accuracy
± 0.4% relative temperature accuracy
12 bit resolution for humidity measurement
14 bit resolution for temperature measurement
Calibrated digital output
Eksellent long-term stability
Each sensor has its own unique 64-bit serial number
1-wire communication - 2 x RJ11 connectors for daisy chain coupling.
± 3.0% relative humidity accuracy.
12 bit resolution for the moisture measurement.
14 bit resolution for temperature measurement.
calibrated digital output.
Eksellent long term stability.
Each sensor has its own unique 64-bit serial number.
1-wire kommunikation - 2 x RJ11 stik til daisy chain kobling
2 - 3 - 4 tråds Pt100 temperaturføler - 4-tråds anbefales.
Indbygget A/D konverter med kompensering
24 bit opløsning for temperatur måling
Kalibreret digital output
Eksellent langtids stabilitet
Hver føler har eget unik 64 bit serienummer
1-wire Current Loop Transmitter - 2 x RJ11 til daisy chain
Stor nøjagtighed - 10 bit opløsning
0-20mA og 4-20mA, 0,01mA opløsning (+/-2%)
Galvanisk isolation
IP30 tæt
Eksellent langtids stabilitet
Hver enhed har et unik 64 bit serienumber
1-wire barometrisk trykmåler, 2 x RJ11 til daisy chain
Relativ præcision på 0.12hPa
Høj elektromagnetisk (EMC) immunitet
Høj linearitet og nøjagtighed
Nem installation
Eksellent langtids stabilitet
Hver enhed har egen unik 64 bit serienummer
Temperature sensor TST300V2 with RS485 interface ±0.13°C accuracy from +20°C to +60°C 14 bit resolution 2 x RJ45 for daisy chain connection to the next sensor IP20 sealed housing Low power consumption Modbus address table: see TST300 manual Log in to danbit.dk and press DOWNLOADS
Combination sensor for temperature and humidity measurement
Modbus RTU
2 x RJ45 connector - with daisy chain to the next module
RS485 Bus to Controller.
Up to 32 devices can be connected Controller
3.0% relative humidity measurement accuracy
12 bit resolution for humidity measurement
14 bit resolution for temperature measurement
With the mounting flanges
Excellent long term stability
Each module has its own ID code
Modul til detektering af vekselspænding - 85 - 250VAC
Threshold +/-8 VAC
Galvanisk isolation mellem AC og digital output Open Collector
2 niveauer med jumper
Lav temperaturdirft
Strømforsynes fra AC siden
DAQ software til TERACOM Ethernet baserede måleenheder Brugervenlig WEB interface for nem konfigurering og kontrol Fleksible bruger adgang og management Distribueret monitorering af måleenheder i “client” mode Alarm advisering Aktivitets log Grafisk og data visning med stor visualisering Nem adgang til rå-data, tabeller, eksport in .csv format (kommasepareret) Database management Sende kommando til kontrollere in “server” og “client” mode Kommando status log
GSM-alarm - ONLT FOR 2G
Setup via USB with Windows setup program, SMS and HTTP API
2 digital "dry contact" inputs
2 analog inputs, 0 - 10VDC - with resistance can be changed to input
2 mA analog inputs, 0 -10VDC or 0-20mA, 10bit (WEB control)
4 relay outputs, NO and NC
1-wire input for up to 8 Teracom sensors
RS485 interface for max. 8 MODBUS RTU sensors
data logger with memory for 70,000 logs
Upload data to HTTP Server
SMS alert to max. 5 recipients
Email alert for max. 5 receivers (SMTP with TLS support)
relay outputs with calls
12 to 24VDC, 350mA @ 12VDC - acquisitions PSU
Multi-Network Output Module with Galvanic I / O
10/100 Mbit Ethernet Connection
Password Protected WEB Server
2 Analog Outputs with Voltage and Power Generator
0 - 20mA, 4 - 20mA, 0 - 24mA
0 - 5V or 0 - 10V voltage output
4 digital (open drain) outputs with ON / OFF or PWM
2 relays with COM, NO and NC contacts
4 scheduled actions, 1 time or weekly
NTP, SNMP v2, SNMP trap for up to 5 recipients
MODBUS TCP / IP
HTTP upload with current status in XML or JSON remote server file
HTTP API commands in server and client mode
HTTP Post can be sent to 3 servers
DIN rail / wall mounting
Supply voltage: 10 - 32VDC / max 250mA
Multi input data logging for up to 70000 login
10/100 Mbit Ethernet
Password protected, web-based configuration and control
4 digital inputs, compatible with S0 pulse interface
6 analog inputs with 0 / 10V and 0 / 20ma
Modbus RTU interface for up to 24 sensors (registers)
Up to 24 channels for monitoring
Up to 24 Independent Alarms
SNMP V.2 Support - SNMP Trap - Alarm Alerts
HTTP and SNMP port change - HTTP API commands
Periodic HTTP post of XML / JSON Status files for client server systems
Modbus TCP / IP support
Dynamic DNS with dynns, no- IP and DNS-O-MATIC Support
NTP protocol support
supply voltage: 10 to 32V DC
Smoke alarm with a diameter of 15 meters installation up to 11 meters high With potential-free relay contact Smoke sensitivity: EN 54-7:2000+ A1:2002 Operating temperature: -10 to +55 °C Dimensions: Ø100 mm, h 47 mm Weight: 100 g
Get your free license key from Teracom
DAQ software for Teracom Ethernet-based measuring devices
User-friendly WEB interface for easy configuration and control
Flexible user access and management
Distributed monitoring units in "client" fashion
Alarm notification
Activity log
Graphics and data display with large visualization
Easy access to raw data, tables, export in CSV format (comma separated)
Database management
Send command to check in "server" and "client" mode
command status log
Remote collection of data, remote meter monitoring, energy management
Energy Meter Interface Module with MODBUS RTU
RS-485 interface with up to 63 units per BUS
Built-in 120 ohm termination resistor
Flash memory data and setup
Power supply from 5 to 32VDC, 25mA at 5VDC
Galvanic isolated digital input - 10mS pollinghastighed
Optional inputs: Open / Closed (dry contact and 32 bit counter)
S0 pulse counter applications :
Remote monitoring of electricity meters
Industrial process control
Remote monitoring of gas meters and water meters
monitoring devices with S0 outputs;
process monitoring
DIN rail mounting
Firmware update via interface.
Dim: 35 x 86 x 59 mm
Multi-band 4G LTE Cat.1 controller, logger and alarm Setup via USB, SMS and HTTP API USB setup - use USB cable with Mini B male 2 digital "dry contacts". High on contact 2 analog inputs, 0 - 10VDC or 4-20mA input (10bit) 4 relay outputs, COM, NO and NC 1-Wire input for up to 8 Teracom sensors 1 x RS485 for max. 8 MODBUS RTU sensors Data logger with 70,000 logs Upload data to HTTP/HTTPS Post in XML/JSON SMS alarm and Email alarm to 5 recipients Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup. 10 to 28VDC, 370mA @ 12VDC - additional PSU Dimensions: 158 x 119 x 34 mm Weight: 470g Temperature: -20 - +55°C
1-wire Combi Sensor
Temperature: -20 - +60 ° C +/- 0.6 ° C
Resolution: 0.1 ° C
Humidity (Moisture): 5 -95% Rh +/- 5%
Resolution 0.1%Rh
IP54 Plastic housing, very sturdy
Up to 8 sensors on the same 1-wire
16 bits at temperature
12 bits at moisture
Supply Voltage: 4.5 / 25mW
Dimensions: 74 x 66 x 36 mm
1-wire lysmåler til synligt lys
0 - 83.000lux med 1 lux opløsning
Op til 23bit opløsning
Automatisk fuld skala justering
Kan kaskadekoples via RJ11 stik
Forsynes fra Controller med 5VDC/4mA
Maks. 30 meter kabel
Mål: 85 x 35 x 24 mm
IP30 plasthus med flange
GSM / LTE alarm - 4G Configuration via USB (Windows program) or SMS 2 x digital inputs with "dry contact" or "logic level" mode 2 x analog input from 0 to 60VDC, 10 bits 2 x relay output with NO / NC switches 1-Wire interface for 4 Teracom temperature and humidity sensors Input can be navigated with alarm text etc. SMS alarm - up to 5 numbers Email alarm - up to 5 email recipients, SMTP with TLS support 1 relay can be activated with calls from up to 100 telephone numbers Push mode - XML data is sent via HTTP Post to a remote server. Server response may include relay setup. MQTT 3.1.1 support Firmware update "on air" Supply voltage: 8 - 32VDC, 2Watt - additional PSU Dimensions: 109 x 65 x 32 mm Weight: 152g
Multisensor for CO2 and barometric pressure Interface: 1-wire (+/- and data) LED indicator for communication status Long-term stability based on digital signal processing Self-calibration on fresh air for CO2 measurements Interchangeable communication parameters Non-volatile memory for all settings Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g Supply voltage: 4.5 - 26VDC / Max. 150mA
Multi sensor for CO2 and Barometric pressure Interface: RS485 - MODBUS RTU LED indicator for status of communication Long-term stability based on digital signal processing Self-calibration on fresh air for CO2 measurements Changeable communication parameters Non-volatile memory for all settings Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g Supply voltage: 4,5 - 26VDC / Max. 150mA
Temperature and humidity sensor 1-wire interface for Teracom controller Temperature: +/-0.4 °C (-10 to +60 °C), max. +/-0.6°C Resolution: 0.1°C Humidity: +/-3.0% RH (20 - 80% RH), max. +/-5% relative humidity Solution: 0.1% RH Supply voltage: 4.5 - 26VDC LED indicator for communication status Long-term stability based on digital signal processing Changeable bit rate and other communication parameters Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g
Temperature and Humidity sensor RS485 MODBUS RTU Temperature: +/-0,4 °C (-10 to +60°C), max. +/-0,6°C Resolution: 0,1°C Humidity: +/-3,0% RH (20 - 80% RH), max. +/-5% RH Resolution: 0,1% RH Supply voltage: 4,5 - 26VDC LED indicator for status of communication Long-term stability based on digital signal processing RS-485 interface (2-wire) carrying up to 32 nodes Changeable bitrate and other communication parameters Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g
Multi sensor for CO2, Temperature and Humidity Interface: RS485 - MODBUS RTU LED indicator for status of communication Long-term stability based on digital signal processing Self-calibration on fresh air for CO2 measurements Changeable communication parameters Non-volatile memory for all settings Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g Supply voltage: 4,5 - 26VDC / Max. 150mA
Web based Data collector module with built-in WebServer Supports MQTT 3.1.1 protocol 4 x digital input Dry - external contact without voltage 4 x analogue inputs with 0 to 10VDC, 0-20mA 4 x powerful relay outputs with NO/NC contacts RS485 port MODBUS RTU up to 24 registers (sensors) Modbus TCP/IP support Data logger with memory for 70,000 logs SNMP v3 support with trap alarm 4 pcs. schemes for real-time control of relay Up to 24 independent alarms Secure email XML/JSON and HTTP API commands for client-server Dynamic DNS support for DynDNS, No-IP and DNS-O-Matic NTP time sync Supply voltage: 10 - 32VDC - purchase PSU Dimensions: 145 x 90 x 40 mm
1-wire Temperature / Humidity sensor Temperature -20 - +60°C Humidity 10 - 90% RH Temp tolerance +/-0.4°C at -10 - +60°C Moisture tolerance ±3.0%rH at 20 - 80%rH Long term operation ±0.25%/year at 20 to 80%rH Long-term operation ±0.05°C/year at -10 to +60°C Solution 0.1 %rH 0.1 °C Power supply/consumption 4.0 to 5.5 VDC 5 mA Dimensions 62 x 28 x 16 mm Cable length 1 m
1-wire temperature and humidity meter 12 bit resolution when measuring moisture 14 bit resolution when measuring temperature Good long-term stability LED communication indicator Dimensions: 99 x 66 x 36 mm Weight: 70g
GSM/LTE alarm - 4G - Global version Supports all LTE frequencies Configuration via USB (Windows program) or SMS 2 x digital inputs with "dry contact" or "logic level" mode 2 x analogue input from 0 to 60VDC, 10 bits 2 x relay output with NO/NC contacts 1-Wire interface for 4 Teracom temperature and humidity sensors Input can be navigated with alarm text etc. SMS alarm - up to 5 numbers Email alarm - up to 5 email recipients, SMTP with TLS support 1 relay can be activated with calls from up to 100 phone numbers Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup. MQTT 3.1.1 support Firmware update "on air" Supply voltage: 8 - 32VDC, 2Watt - purchase PSU Dimensions: 109 x 65 x 32 mm Weight: 152g
Global 4G LTE Controller, logger and alarm Supports all LTE frequencies Setup via USB, SMS and HTTP API USB setup - use USB cable with Mini B male 2 digital "dry contacts". High on contact 2 analog inputs, 0 - 10VDC or 4-20mA input (10bit) 4 relay outputs, COM, NO and NC 1-Wire input for up to 8 Teracom sensors 1 x RS485 for max. 8 MODBUS RTU sensors Data logger with 70,000 logs Upload data to HTTP/HTTPS Post in XML/JSON SMS alarm and Email alarm to 5 recipients Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup. 10 to 28VDC, 370mA @ 12VDC - additional PSU Dimensions: 158 x 119 x 34 mm Weight: 470g Temperature: -20 - +55°C