CAN Bus Power Extension Module
Compact and efficient power module for CAN bus systems
Subcategories
There are 45 products.
Compact and efficient power module for CAN bus systems
100A AC current measurement with 0-5V DC output for remote monitoring
Outputs 4 pin terminal
Power Input -12V / +12V
Operating Temperature -10° C to +80° C
Dimensions: 60 × 61 × 16 mm
Weight 150 g
Power Consumption 1 Watt
Detects door/window opening via magnetic contact separation
Purpose Detects opening of doors/windows in IT racks, cabinets, etc.
Compatibility Works with Vutlan monitoring systems and other alarms.
Operating Humidity 5 - 95%
Operating Temperature Range -10 - 50 °C
Connection x2 cables to 3.5mm power terminal connector.
720P resolution
Dome Camera
Compatible with USB 2.0 and 1.1 interfaces
Equipped with infrared (IR) capabilities for low-light environments
1.0 megapixel sensor for clear image capture
Cable length of 5 meters
12V DC sound and light alarm with 108 dB sound pressure and 3.8 kHz tone frequency
Input: Connects to 12V DC, 0.25A electronic relay
Cable Length: 1.5 m
Installation: Wall or ceiling mount
Functionality: Can be controlled manually or through logic in the device interface
Max Current Consumption: 250 mA
Operating Temperature: -50° C to +105° C
Operating Humidity: 5% to 95% (Non-Condensing)
Compact 12V LED strobe light with high visibility for security alarm systems
Cable Length 3m
Input 2-wire cable
Voltage 12V
Rated Current 120mA
Flashing Frequency 90/min
Power Consumption 1 Watt
Operating Temperature -50° C to +105° C
Operating Humidity 5% to 95% (Non-Condensing)
Dimensions Height 73.5mm, Diameter 45.5mm
Weight 110g
Compact relay switch for HVAC control
Function Switchable contact for equipment control
Applications Air conditioners, magnetic locks, bolt locks, sirens, heaters, etc.
Compatibility Connects to units with 12V outputs
Input Wire terminal 3.81mm 2P
Output Wire terminal 5.0mm 2P
Operating Temperature -50° C to +105° C
Operating Humidity 5% to 95% (Non-Condensing)
Mounting Includes bracket, sticker, and screws
Power Consumption 12 mW
Max Switching Voltage 250VAC / 30VDC
Max Switching Current 5A
Max Switching Power 1250VA / 150W
Weight 60 g
Dimensions 60×18×18 mm
Compact environmental monitoring for IT rooms with the possibility of sensor expansion
CPU speed/RAM/OS 600MHz, 128Mb, Linux v.6.2
USB port For cameras, flash drives, hubs
Analog ports 4 (can be extended)
CAN port 1 (max. 10 sensors and extensions)
Dry Contact inputs 2 digital inputs
Relays 2 outputs (12V, 0.25A each)
Ethernet 10/100 Mbps
Robust monitoring solution for IT environments with extensive sensor support
Analog Ports: 4 (extendable)
CAN Port: 1 (max. 10 sensors & extensions)
Dry Contact Inputs: 2 digital inputs
Relays: 2 outputs (12V, 0.25A each)
Ethernet: 10/100Mbps
USB Port: For cameras, flash drives, hubs
Dimensions 190 x 33 x 91mm
Designed for DIN rail installations, this monitoring controller offers comprehensive sensor integration
Built-in LTE modem is sold separately and can be purchased separately
Analog ports 6
Digital inputs: 4
Digital outputs: 2 isolated, max. 24VDC, 15mA
Relay outputs: 2 electromagnetic, 12VDC, 0.25A
Built-in sensors temperature (±1°C accuracy), voltage (1% accuracy)
Modbus RTU Supports up to 32 devices
Operating temperature: 0 to 70°C
Dimensions: 160 x 90 x 58 mm
Power supply: DC 12V
High precision DC power conversion device with extended range compatibility
Compact and efficient DC current monitoring solution
Inputs RJ-12 / RJ-11
Operating temperature -10°C to +80°C
Power input 12V DC, 1A
Power consumption 100 mW
Dimensions 68 × 47 × 26 mm
Weight 160 g
Compact and efficient AC current monitoring solution
Inputs RJ-12 / RJ-11
Operating temperature -10°C to +80°C
Power input 12V DC, 1A
Power consumption 100 mW
Dimensions 68 × 47 × 26 mm
Weight 160 g
Compact unit to increase analog sensor capacity for monitoring systems
Add up to 8 sensors per unit
Ports x8 RJ11 6P4C, x2 CAN bus
Power 12V DC, 0,5A
Operating temperature Min. -10° C - Max.+80° C
Dimensions 129 x 28,6 x 56 mm
Expands sensor capacity for enhanced monitoring
Connects up to 8 analog sensors
Ports x8 RJ11 6P4C, x2 CAN bus
Power 12V DC, 0.5A
Operating temperature -10° C to +80° C
Dimensions 107 x 90 x 65mm
Weight 130g
Compact and efficient DC voltage monitor for systems up to 15V
Voltage Measurement 0-15V
Operating Temperature -10° C to +80° C
Output 4 pin terminal
Weight 100 g
Power Consumption 100 mW
Dimensions 60×18×18 mm
Mounting: Desktop, Wall mount
Package Contents DC voltage monitor, 3m shielded cable (6P6C RJ12), TBW 5-2P
Compact and efficient DC voltage monitor for systems up to 75V
Voltage Measurement 0-75V
Operating Temperature -10° C to +80° C
Output 4 pin terminal
Weight 100 g
Power Consumption 100 mW
Dimensions 60×18×18 mm
Mounting: Desktop, Wall mount
Package Contents DC voltage monitor, 3m shielded cable (6P6C RJ12), TBW 5-2P
Compact converter for current measurement and data conversion for IP monitoring systems
Input Terminal Plug 2pins 5mm
Output Terminals RJ11 / RJ12
Power Consumption 100 mW
Dimensions 60×18×18 Mm
Weight 60 g
Compact and efficient rack monitoring solution with essential environmental sensors
Type CAN digital sensor
Power Supply Over CAN bus
Humidity Accuracy ±3%
Temperature Range -10 to +85 °С
Temperature Accuracy ±1 °С
Optimal Temperature Range: -10° C to +80° C
IR Sensor Distance 1-4 cm
Weight 270 g
Dimensions 89 x 27.1 x 48.2 mm
Inputs x2 dry contacts, x2 RJ-12 ports
Package Includes Unit, mounting bracket, screws
Compact digital unit for expanding dry contact capacity
Adds x32 dry contact inputs
Input Terminals 32 dry contacts
Daisy Chain Support
Operating Humidity 0 to 95%
Storage Conditions -40° С to +100° C, 0 to 95% humidity
Operating Temperature -10° C to +80° C
Dimensions 215 x 40 x 40 mm
Mounting Options 19" rack, desktop, wall mount
Power Consumption 1 Watt
Package Includes Dry contacts unit, cable, rubber foot, terminal, screws, rack brackets
Compact and efficient sensor for accurate pressure, humidity, and temperature readings
Sensor Type CAN digital
Pressure RMS Noise 0.2Pa (1.7cm equivalent)
Pressure Error ±0.25% (1m at 400m height change)
Pressure from °C: ±1.5Pa/K (±12.6cm at 1°C change)
RH Accuracy ±3% RH (max)
Hysteresis ≤2% RH
Temperature Accuracy ±1.5°C
Pressure Range 300 to 1100 hPa
Operating Temperature -40 to +85 °С
Power 12V DC 1A, 1 Watt
Dimensions 68x47x26 mm
Weight 160 g
Mounting Options Desktop, Wall mount