12VDC 1.5Amp (18Watt) power adapter from 110 - 240VAC, plug 5.5 / 2.1mm
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
Ethernet Gateway for CANopen networks and Modbus RTU
1 x RJ45 10 / 100Mbps
Protocol: Modbus TCP Server
1 x RS232 / RS485 port (non-isolated)
Modbus RTU slave
Baud rate: 1200-115200
1 x CAN port
CANopen
CAN Baud rate: 10K - 1M
Built-in 120 ohm termination
Dimensions: 122 x 72 x 33 mm
Supply voltage : 10 - 30VDC, 2,5Watt
Operating temperature: -25 - + 75 ° C
DIN bracket
M485-CAN-M-ETH-in module that provides a communications transformation between CANopen protocol and Modbus / TCP RTU protocols. It solves a job-bo representation problem in connecting to an existing CANopen network with an Ethernet Master unit, as long as the Master Unit supports Modbus / TCP protocol.
It allows the CANopen network to be linked to the Internet / Ethernet wherein the remote monitoring and control is achieved. For CANopen network is CAN-M485-M-ETH-In a CANopen master unit. It supports PDO and SDO functions for communication with the slave devices. From the view of Modbus / TCP counter bid / RTU network operates M485-CAN-M-ETH-In a Modbus / TCP server or Modbus / RTU slave role. It can receive commands from Modbus / TCP client or Modbus / RTU master and process the commands to reply or send the related CANopen data. We provide utilities for users to configure the parameters of the CANopen slaves M485-CAN-M-ETH-I. When M485-CAN-M-ETH-In starts up, gathers the necessary information from all slaves that are predefined in the M485-CAN-M-ETH-I using the utility. The figure on the page shows the application architecture for the CAN-M485-M-ETH-I.
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
NMT Canopen Slave
Modbus RTU Master
Error Control: Node Guarding Protocol
Node ID: Setting CAN_MRU Utility Software or LSS Protocol
PDO modes: Eventless, externally requested, cyclic and acyclic Sync
Bob Mapping: Variable
Number of SDOs: 1 Server, 0 Client
Canopen Version: DS-301 V4.02
Device Profile: DSP-401 V2.1
CIA DSP -305 V1.1
Can Baud Rate: 10K - 1M BPS
Modbus Baud Rate 1200 - 115,200 BPS
LED indicators Run, Err and Overrun
Max. 10 Modbus RTU I / O Modules
Hiring program for configuration
7-segment LED to display Node ID, Can Baud Rate and RS-485 Baud Rate
RS485 module for 6 Temperature sensors
6-channel RTD input
3-wire RTD input with elimination of wire resistance
Resolution: 16-bit
Individual channel configuration
Disconnected sensor detection
Double Watchdog
Supply: 10 - 30vdc
Operating temperature: -25 to + 75 ° C
Ethernet module with 2 digital inputs and 1 relay output
2 x digital dry contact - active high by connecting contact
1 x Power relay, 250vac / 5a, 30vdc / 5a
Avoid inductive load to relay
P2P Function that reflects an input to other module output
Supports Modbus / TCP and UDP Slave
Power supplied from PoE or 12 - 48VDC
PoE: IEEE802.3af, Class 1
Operating temperature: - 25 - + 75 ° C
Dim: 98 x 52 x 27 mm
DIN bracket
Til mindre styringsopgaver, med TFT display og touch