Web Enabled Programmable Controller with Log, 4 x Digital in, 4 x Relay Out COM NO Common Com, 1-Wire Bus, P2P, 9 - 28VDC

Web based controller with I/O, 1-wire bus
4 x digital inputs (Common GND)
1-wire bus, max. 16 sensors (temp / moisture etc.)
Permissions: Administrator, Manager, User
Tasks
50 Scheduled
50 Conditional
16 Automatic Restart
20 Over Rule Terms
E-mail Alarms by defined conditions
Supports encrypted e- Mail servers such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Configurable Logging
Graph (Logged Data)
HTTPS / TLS encrypted
Static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC

X-410-I
4,382.00 DKK
Tax excluded
Quantity
Physically in stock  

  • Download PDF
  • file_download Downloads
  • live_help Ask a question

Web-enabled programmable controller.
X-410-I have 4 digital inputs, 4 relays, 1-wire bus for a maximum of 16 1-wire sensors and a built-in web server that enables remote access from many devices along with Infinite governance and monitoring options. Has built-in 4 relays (1A at 28VAC, 24VDC) with common com to e.g. Low voltage, engines, locks, solid state relays (associated with larger loads). 4 digital inputs (optoized 4-26VDC). Monitor to / from mode or configure as digital counters or frequency measurement. It can be used to monitor switches, alarm sensors, level sensors, flow sensors and more. Up to 16 temperature / humidity sensors on the same 1-wire bus.
Monitor up to 16, 1-wire sensors such as: Temperature and moisture sensors (not supplied). X-410 - I support peer-to-peer communication between ControlByWeb modules. It supports communication with up to 32 modules and allows you to check and monitor up to 100 I / O channels. The X-410 - I can communicate with all ControlByWeb devices, but offers immediate message between products in the X-400 series, which means that X-410 can control and monitor I / O on other products in the X-400 series, which whether it was directly connected to the module. The X-410-I's built-in interface allows you to create custom "tasks" for simple and advanced control logic. Easily create tasks based on time, input or output status or device response. Create up to three actions for each task so you get the ultimate control and monitoring solution for your application. Create up to 50 planned, 50 conditional, 16 automatic restart tasks and 20 overlay plans.
I / O Task Builder is conditional tasks triggered depending on I / O status. Conditional tasks are often used to send alarms at high / low temperature, control alarms, etc.
Scheduled tasks perform actions on preset times at specific days. You can also choose to override these scheduled tasks at specific days (ie holidays). Scheduled tasks are often used for controlling light columns for parking space, stadium light, magnetic locks, generators, etc.
Advanced logic from restarting devices automatically (cameras, routers, servers, etc.) when they do not respond. Also write Basic script for more advanced logic.
X-410-I allows you to log a number of data points as local and external I / O, registers, tasks and excitement. Log inputs can be made with preset intervals, scheduled times, triggered by I / O changes or logical events. Plan a daily log file to be sent by e-mail or uploaded via FTP server. Graphing of the current log file and see I / O status over time.