Active Rod antenna Atomic Time
Accessories
DCF 77 kHz rod antenna w/5 meter cable
For ATOMUR-SAT-T+
Must be mounted horizontally (landscape)
Must face south (Frankfurt, Germany)
Is sensitive to EMC noise which can interfere with reception
NTP Server - Atomic clock for 19 rack mounting.
Signal from DCF77 in Frankfurt (77.5kHz).
Rod antenna with 5 meter cable with BNC male
Additional antenna cable 50 ohm, BNC male/male
Purchase BNC-SAMLE
With network port and serial port
1U for rack mounting
Power is supplied from 230VAC.
ATOMUR-PRO19 has an external antenna and can be used in places where there are otherwise problems with receiving the signal. ATOMUR-PRO19 can be installed as an SNTP server so that Servers/Clients can retrieve the time via the network. All models receive the DCF77 radio signal at 77.5 KHz from Frankfurt. The range is approx. 2000 km.
Connects to a serial port 9600 bps or network port 10/100 Mbit
Shows time and date on a display as well as reception conditions using a series of LEDs.
Power supply: Has a built-in 230 VAC power supply
Distance from receiver to PC: Can be extended on the BNC connector (antenna port) by up to 2 x K-ATOMUR+50 (RG174U cable á 50 m, 50 ohm) – a total of 100 m.
Software: Windows 2000, XP, 2003, Vista 32/64 and Win 7 as well as Linux using the serial port.
Accessories
DCF 77 kHz rod antenna w/5 meter cable
For ATOMUR-SAT-T+
Must be mounted horizontally (landscape)
Must face south (Frankfurt, Germany)
Is sensitive to EMC noise which can interfere with reception
Forlængerkabel til DCF antenne, 50 meter
7 ports PDU with overall power meter via network
can measure residual current measurement
One power meter can be reset, the other accumulates consumption.
User interface via web browser with Password
7 x IEC C13 outputs, max. 16A (safety socket)
1 x RJ45 to LAN and 1 x RJ45 for external sensor, temperature, moisture, hPascal
SNMP Get / traps and e-mail support
8 port PDU with individual on / off and overall energy measurement via network
Network Monitoring, for example. PRTG, Icinga, Nagios, Power IQ, Tivoli
19 "rack mount, 1U
1 x C20 input 230V, 16A
User interface via web browser with password
Scheduled power on / off per port
programmable sequential power up
8 x IEC C13 outputs, max. 10A
2 x inputs for temperature and temperature / humidity sensor with an alarm
8 x Watchdog with ping to each connected PC
SNMP Get / traps and e-mail support
Supports iPhone and Android
The ideal choice for Server Room and Server rack monitoring.
4 x potential-free switching relay outputs - 36VDC / 3A switches
Large LED display for power measurement, IP address, sensor data and error reports
4 x Watchdog for monitoring connected PCs (ICMP / TCP)
12 x passive signal inputs - (contact inputs) for Phoenix plugs
4 x RJ45 for temperature / humidity sensors. RS232 / 485, 1 x RJ45 for LAN
Features, limit values, alarm receivers set up on the device via supplied software
2 x 12VDC power supply inputs (redundant)
PoE - Power over Ethernet for 2111-2 the model.
Free APP for Android and iPhone
SNMP Get / Traps (SNMPv1, v2c, v3)
4 ports PDU med samlet strømmåler via netværk
Med reststrømsmåling type A.
19" rackmontering, 1U
Måling af energi og elektriske dimensioner
Integreret Hotswap skuffe til udskiftning af processor/strømforsyning under drift
Måling af 2 resp. 4 separate faser
4 x IEC C13 udgange 14A
3 x RJ45, LAN og Sensor
4 x IEC C20 Strømforsyning 16A
SNMP Get/traps