Network-based device for switching on/off 230 VAC equipment.
Web server built-in - password protected
Can ping a stable IP address and if there is no response - turn equipment off and on
Timetable for on and off - scheduler
Mains socket is SCHUKO
The power supply for 230 VAC devices can be controlled with the NPOWER1+ which is inserted between the power supply and the device. From any PC on the local network (or over the Internet), the relay in the NPOWER1+ can be switched on and off.
The device is operated by entering the IP address of the NPOWER1+ in a Web browser, after which a built-in homepage (web server) appears. It can possibly be used to restart equipment that may be locked, such as routers and PCs. In this way, it is easy to restart, for example, a locked server and with the Watchdog timer function an ADSL cable modem or router, if it does not receive a response from the Internet.
Remote control of 230 VAC supply via local and internet.
10/100 Mbit Ethernet connection with RJ45 connector.
Supports HTTP, TCP/IP, SNMP, DHCP, DDNS and NTP protocols.
NOTE: Rebooting equipment or turning it on/off via the Internet requires a known IP address - either a fixed one or you can use Dynamic DNS (DDNS). This requires that the router supports DDNS, which works in such a way that the router contacts the DDNS provider (e.g. dyndns.dk) and provides its current dynamic IP address, after which the DDNS server associates the dynamic IP address with a fixed web address, e.g. "minkonto.dyndns.dk" or "www.mitdomæne.dk/npower1". To use this function, an account must be created with dyndns.dk or other DDNS providers.
It also requires that the selected port in NPOWER1+ be forwarded to NPOWER1+'s internal IP address in the router.
IEC 320 C14 Male Plug to European CEE 7/7 3Pin Female Socket Power Cord , C14 to EU SCHUKO PDU UPS Cable, 1.8 meter
The ideal choice for Server Room and Server rack monitoring.
4 x potential-free switching relay outputs - 36VDC / 3A switches
Large LED display for power measurement, IP address, sensor data and error reports
4 x Watchdog for monitoring connected PCs (ICMP / TCP)
12 x passive signal inputs - (contact inputs) for Phoenix plugs
4 x RJ45 for temperature / humidity sensors. RS232 / 485, 1 x RJ45 for LAN
Features, limit values, alarm receivers set up on the device via supplied software
2 x 12VDC power supply inputs (redundant)
PoE - Power over Ethernet for 2111-2 the model.
Free APP for Android and iPhone
SNMP Get / Traps (SNMPv1, v2c, v3)
3 x tænd/sluk, potentialfri relæ ouputs, 230 V AC, 16 A / 24 V DC, 10 A
1 x strømforsyning med 12-24 V AC / DC spænding
1 x RJ45 Ethernet
3 x Watvhdog til at overvåge forbrugere (ICMP / TCP)
1 Mini-DIN-stik til valgfri sensor eller seriel interface (RS232)
Programmerbar tænd / sluk-sekvens
SNMP Get/Traps (SNMPv1, SNMPv2c)
Understøtter Android og iPhone
Syslog og E-mail
DIN-rail montering i servere racks
Intelligent 8 ports Power Distribution Unit
Justerbar sekventiel tænd / sluk
Samlet strømovervågning
Samlet spændingsindgang
Outputovervågning
Total brugt kWh
Effektfaktorgenkendelse
Driftstemperatur: Op til +55°C
8 x låsbar IEC-C13 netudtag
120 - 240VAC
Styr op til 3 PDU slaver fra en master
1 x C20 16Amp
Sensor for temperatur- og fugtighedsalarm
Alarm for vand via infrarød sensor
Røgdetektor
Automatiske alarmmeddelelser
Track - 20 x 230 V outlet, built-in power consumption meter.
Can be cascaded with nine slaves.
Ethernet password. logo Email alert for exceeding limits and the errors
1-pole relay output - switcher L