Remote monitor over Ethernet with 24 input ports. 4 Digital input, S0. 6 x analog input. RS485. Modbusrtu to Modbus TCP. SNMP

Multi input data logging for up to 70000 login
10/100 Mbit Ethernet
Password protected, web-based configuration and control
4 digital inputs, compatible with S0 pulse interface
6 analog inputs with 0 / 10V and 0 / 20ma
Modbus RTU interface for up to 24 sensors (registers)
Up to 24 channels for monitoring
Up to 24 Independent Alarms
SNMP V.2 Support - SNMP Trap - Alarm Alerts
HTTP and SNMP port change - HTTP API commands
Periodic HTTP post of XML / JSON Status files for client server systems
Modbus TCP / IP support
Dynamic DNS with dynns, no- IP and DNS-O-MATIC Support
NTP protocol support
supply voltage: 10 to 32V DC

TCW260
3,204.00 DKK
Tax excluded
Quantity
Physically in stock  

  • Download PDF
  • file_download Downloads
  • live_help Ask a question

TcW260 is an energy monitoring module with an Ethernet interface and data logger functionality. All its inputs are galvanically isolated from the power supply.
The module has 4 digital inputs, S0 compatible.
The digital inputs can work in ON / OFF or counter mode. There are also 6 analog inputs. Each analog input can work either in voltage (0 - 10V) or power loop (0 - 20mA). TCW260 supports Modbus RTU interface for teracom and third-party sensors. RS-485 interface is fully insulated from the power supply.

Technical data:
Up to 24 channels for voltage (Volt) / Power (MA) or Energy Monitoring
Up to 24 Categorized Alarms with Flexible Setup parameters

4 Isolated digital inputs with S0 interface (EN62053-31)
On / Off and Counter (Counter) Digital Inputs
6 Isolated Analog Inputs with 0 - 20ma or 0 -10V. Br> RS-485 isolated interface with up to 24 Modbus RTU registers (sensors)
Password Protected Web based configuration and control

Dimensioner
145 x 90 x 40
Driftstemperatur
-20° - +55°C
Hukommelse
Internal FLASH memory Settings segment endurance: 100 000 cycles (Every setting change is a memory cycle). Data logger segment endurance: 100 000 cycles of 70000 records. Update segment endurance: 100 000 cycles (updates).
Indgang
Isolation: Isolated (1000VDC) Type: Single ended Resolution: 10 bits Mode: Voltage or current loop Input Range: 0/10V or 0/20mA Accuracy: ±1% Sampling Rate: 600mS per channel (averaged value of 100 samples) Input Impedance: 1 mega-ohm (min.)
Indgang
Isolation: Isolated (1000VDC) Mode: OPEN/CLOSED (“Dry contact”) or COUNTER (S0-pulse interface outputs) Maximum input voltage: +5.5VDC Sampling rate: 1mS Digital filtering time interval: 5 to 60000mS
Luftfugtighed
10 to 80% (non-condensing)
Strømforbrug
220 mA @ 12 VDC (without RS-485 powering)
Strømforsyning
10 til 32V DC
Weight
200g