2 x 230VAC power relay /16A – resistive load.
2 x DC switched outputs up to 40VDC/6A, also as PWM for LED, FAN, etc.
2 x independent inputs: 230VAC and up to 24VAC/24VDC, SMS alerts for power failure
SIM card and SD card
Backup battery (not included) as an option – Li-Ion 3.7V (14500)
Switch appliances on and off with SMS messages
GPRS M2M function, TCP/IP Get to directly send input status to Server
Get XML status from server to set device outputs.
Scheduled automatic switching on and off of appliances
Sends power failure warning and recovery.
Restarting appliances, such as servers.
Monitoring of 2 x A/D inputs AC/DC voltages with autodetect
4 x digital inputs DIN1, DIN2, DIN3, DIN4 for DC voltage.
Universal bus (1-wire) for temperature and humidity sensors.
Thermostat function.
Alarm function: Temperature alarm, Humidity alarm, A/D limits, DI change
Alarm in case of jamming of a GSM signal.
Up to 12 alarm numbers, each can be set for different events
Up to 1000 authorized users and 2 administrator numbers.
Bluetooth
All inputs are SO compatible
Serverrum: Overvågning / Styring
Serverrum: Overvågning / Styring
Data center and server room monitoring. Monitoring solutions for data centers and industrial environments. Products include sensors, network devices, and software that allow real-time monitoring and control of various parameters such as temperature, humidity, power, water, and smoke detection. These solutions help ensure the reliable operation of data centers and industrial systems by providing accurate and reliable data for management and operational decisions.

1 channel detection of fluid leakage with MODBUS
Shutter local alarm of detection of water leakage
Acoustic alarm - adjustable
RS485 2-wire MODBUS RTU
2 x LED indicators for power and alarm
Relay output for alarm for water leakage - 30VDC / 2A
Monitor cable for liquid detector
Sensor cable can be up to 500 meters
Sensitivity is adjustable
Supports DCON and Modbus RTU protocols
Embedded Dual Watchdog
Operating temperature: -25 to + 75 ° C
Small form factor with DIN bracket
Dimensions: 83 x 70 x 29 mm
Operating voltage: 10 - 30VDC
Water detector with normally closed relay output
Supply voltage: 5VDC / 10mA
Relay contact: max. 30VDC/500mA
Red: +5VDC
Black: GND
Green: Relay contact
White: Relay contact
REMEMBER: Relay contact opens when water is removed.
Supports optional choice of ports from 8 - 12 - 16 - 20 - 24 ports.
The Current changes with the various models 16 - 32 A.
Current and voltage (total input) measurement;
Built in temperature and humidity sensor
Embedded technology, support Java, web browsing;
Two level values of warning and overload can be set;
LED indicates the power supply status of each switch;
LED digital display shows the current voltage and current values;
Provide local operation query button of PDU device;
Built in lightning protection circuit, anti voltage surge circuit, effective protection of the server;
3 x tænd/sluk, potentialfri relæ ouputs, 230 V AC, 16 A / 24 V DC, 10 A
1 x strømforsyning med 12-24 V AC / DC spænding
1 x RJ45 Ethernet
3 x Watvhdog til at overvåge forbrugere (ICMP / TCP)
1 Mini-DIN-stik til valgfri sensor eller seriel interface (RS232)
Programmerbar tænd / sluk-sekvens
SNMP Get/Traps (SNMPv1, SNMPv2c)
Understøtter Android og iPhone
Syslog og E-mail
DIN-rail montering i servere racks
4 x potential-free shutter release, & 230VAC / 16 A, & 24VDC / 10 A
8 x passive signal inputs - contact inputs
1 x RJ45 Ethernet
4 x Watchdog to monitor connected devices (ICMP / TCP)
1 Mini-DIN connector for optional sensor or serial interface (RS232)
Programmable on / off sequence
SNMP Get / Traps (SNMPv1, SNMPv2c), Syslog, e -mail
APP for Android and iPhone
2-color LEDs for status info on front
DIN rail mounting
The ideal choice for Server Room and Server rack monitoring.
4 x potential-free switching relay outputs - 36VDC / 3A switches
Large LED display for power measurement, IP address, sensor data and error reports
4 x Watchdog for monitoring connected PCs (ICMP / TCP)
12 x passive signal inputs - (contact inputs) for Phoenix plugs
4 x RJ45 for temperature / humidity sensors. RS232 / 485, 1 x RJ45 for LAN
Features, limit values, alarm receivers set up on the device via supplied software
2 x 12VDC power supply inputs (redundant)
PoE - Power over Ethernet for 2111-2 the model.
Free APP for Android and iPhone
SNMP Get / Traps (SNMPv1, v2c, v3)
automatisk transfer switch (ATS) til skifte til en alternativ strømforsyning
Typisk overførselstid 7 - 10 ms.
Brugerflade via web-browser med Password
Programmerbar sekventiel power up
6 x IEC C13 udgange 10A
1 x IEC C19 16A
3 x RJ45, LAN og Sensor
2 x IEC C20 16A strømforsyning
SNMP Get/traps og e-mail support
Bypass-Switch til udskiftning eller vedligeholdelse af uafbrydelige strømforsyninger (UPS)
19" rackmontering, 1U
Synlig LED-Display
1 output „zur USV“ IEC C19, 16A
1 input „von USV“ IEC C20, 16A
6 x IEC C13 udgange 10A
1 x IEC C20 16A Strømforsyning
Lavt internt strømforbrug
Bypass-Switch til udskiftning eller vedligeholdelse af uafbrydelige strømforsyninger (UPS)
19" rackmontering, 1U
Synlig LED-Display
1 output „zur USV“ IEC C13, 10A / IEC C19, 16A
1 input „von USV“ IEC C14, 10A / IEC C20, 16A
4 x IEC C13 udgange 14A
3 x RJ45, LAN og Sensor
1 x IEC C14 10A/ IEC C20 16A Strømforsyning
4 ports PDU med samlet strømmåler via netværk
Med reststrømsmåling type A.
19" rackmontering, 1U
Måling af energi og elektriske dimensioner
Integreret Hotswap skuffe til udskiftning af processor/strømforsyning under drift
Måling af 2 resp. 4 separate faser
4 x IEC C13 udgange 14A
3 x RJ45, LAN og Sensor
4 x IEC C20 Strømforsyning 16A
SNMP Get/traps
4 ports PDU med samlet strømmåler via netværk
Med reststrømsmåling type A.
19" rackmontering, 1U
Måling af energi og elektriske dimensioner
Integreret Hotswap skuffe til udskiftning af processor/strømforsyning under drift
Måling af 2 resp. 4 separate faser
4 x IEC C13 udgange 14A
3 x RJ45, LAN og Sensor
4 x IEC C20 Strømforsyning 16A
SNMP Get/traps
20 ports PDU with individual and total power meters via network
Integrated residual current measurement type A
User interface via web browser with Password
16 x IEC C13 outputs 10A
1 x RJ45 to LAN and 1 x RJ45 for sensor, temperature, moisture, hPascal
4 x Schuko outputs 16A
SNMP Get / traps and email support
20 ports PDU with individual and total power meters via network
User interface via web browser with Password
16 x IEC C13 outputs 10A & nbsp;
1 x RJ45 to LAN and 1 x RJ45 for sensor, temperature, moisture, hPascal
4 x Schuko outputs 16A
SNMP Get / traps and email support
7 ports PDU with overall power meter via network
can measure residual current measurement
One power meter can be reset, the other accumulates consumption.
User interface via web browser with Password
7 x IEC C13 outputs, max. 16A (safety socket)
1 x RJ45 to LAN and 1 x RJ45 for external sensor, temperature, moisture, hPascal
SNMP Get / traps and e-mail support
7 ports PDU with overall power meter through network
One power meter can be reset, the other accumulates consumption.
User interface via web browser with Password
7 x IEC C7 outputs, max. 16A (safety socket)
1 x RJ45 to LAN and 1 x RJ45 for remote sensor (temperature, humidity, hPascal
SNMP Get / traps and email support
12 ports PDU with individual on / off with individual and overall power meter via network
19 "1U rack mount
Integrated power measurement and monitoring per output
User interface via web browser with Password
Scheduled on / off per port
Programmable sequential power up
8 x IEC C13 outputs, max. 10A
2 x inputs for temperature and temperature / humidity sensor with alarm
8 x Watchdog with ping off Every Connected PC
SNMP Get / Traps and Email Support
Supports Iphone and Android
12 ports PDU with individual on / off and individual and overall power meter via network
19 "1U rack mount
Integrated power measurement and monitoring per power outlet
User interface via web browser with Password
Scheduled on / off per port
Programmable sequential power up
8 x Schuko outputs, max. 10A
2 x inputs for temperature and temperature / humidity sensor with alarm
8 x Watchdog with ping off & nbsp; each connected PC
SNMP Get / Traps and Email Support
Supports Iphone and Android
12 port PDU with individual on / off and assembled power meter via network
19 "rack mount, 1U
2 x power supply with 230V, 16A
User interface via web browser with Password
Scheduled on / drain per port
Programmable sequential power up
12 x IEC C13 outputs, max. 10A
2 x inputs for temperature and temperature / humidity sensor with alarm
12 x Watchdog with ping for each connected PC
SNMP Get / Traps and Email Support
Supports Iphone and Android
4 ports PDU with individual power on / off and total current meter via network
1 x Alternative Type E connector (CEE 7/3) max 16A
User interface via web browser with Password
Programmable sequential power up 4 x Schuko outputs type F, max. 16A
4 x Watchdog with ping of & nbsp; each connected PC
SNMP Get / Traps and Email Support
Supporting Iphone and Android
Netværksbaseret enhed til tænd/sluk af 230 VAC udstyr.
Web-server indbygget - password-beskyttet
Kan pinge en stabil IP-adresse (f.eks. Google) og ved manglende svar - slukke og tænde udstyr
Network operated relay box for switching on/off 230 VAC equipment
Shows current power consumption and ambient temperature on PC.
Web server built-in - password-protected.
With IP ping to stable website, it checks network outage.
If there is no response, it turns OFF/ON the desired external equipment.
ON/OFF can be controlled remotely from the browser.
Scheduled ON/OFF
HTTP, TCP/IP, DHCP, DDNS, SNMP v1, SMTP, NTP
Network-based device for switching on/off 230 VAC equipment.
Web server built-in - password protected
Can ping a stable IP address and if there is no response - turn equipment off and on
Timetable for on and off - scheduler
Mains socket is SCHUKO
Power distribution device for on and off of 8 x 230vac
monitoring of total power consumption, temperature.
with slave devices Connected: Up to 128 outlets.
Web-based remote control of switching on/off via the Internet
Built-in Web Server. Username + Password
MQTT, Cloud, SNMP
APP for Smartphone
Watchdog with ping of stable website (Google etc.)
4 x 230 VAC sockets - IEC C-13 output 10A and C-14 input 15A.
Web server built-in - password-protected.
VPN Client
Supports: HTTP, HTTPS/SSL, TCP/IP, PPPOE, DHCP, DDNS, SNMP v3, SMTP, NTP, TLS
Supports: Cloud Connect : AWS IOT, GOOGLE Cloud IoT, Microsoft AZURE IOT
Dimensions: 195 x 116 x 45 mm
Rack fittings are purchased separately
CPU: 720Mhz/ 4 Core/2GB/Linux v.5.10
10/100 ethernet connection
2 x USB to USB camera, USB FLASH, USB HUb
8 x Analog ports
32 x Digital inputs
8 x Isolated digital outputs max. 24Vdc, 15mA
2 x Relay (NC NO COM) max. 10A for AC, 9~30V for DC voltage
LTE slot modem (modem purchased separately)
1 x Audio-Video output & input
SBNP v1, v2c, v3
OpenVPN, SSL, HTTPS
DHCP, HTTP, DynDNS, SMTP, RADIUS, Syslog, NTP server, HTTP request
API
Notification E-mail, phone call, SNMP, WEB to SMS, SMS Link
Logging SD, USB Flash, E-mail, FTP
power supplies single/redundant 24-48Vdc, 230Vac (contact sales regarding versions)
ARM Cortex - A53 CPU , 1.2 GHz
RAM 1Gb SDRAM
16GB of memory
2 x RS232/422/485
8 x DI and 4 x relay outputs
DC input 9-32V
4G module
OS : Linux Raspbian
User need knowledge of linux and programing
Documentation for DI/O and 4G module
Open board til smart temperatur- eller fugt måling and styring
Password beskyttet Web baseret konfiguration og kontrol
1 x digital input med “dry contact” og “logic level” mode
1 x analog input fra 0 til 60VDC
1 relæ output med NO/NC kontakter
1-Wire input til 1 temperature eller fugtmåler
SNMP v.1 support
SNMP traps ved alarm
E-mail udsendelse ved alarm
SMTP med godkendelse (SSL/TLS er ikke supporteret)
HTTP og XML API kommandoer
Remote FTP firmware update.
Mini vertical level switch / swim switch
Assembly: Vertical
contact output: Direct load
Cable length: 30 cm
Operating temperature: -20 ° C to + 80 ° C
AC voltage Max: 130V < Br> DC voltage Max: 180V
Max current: 700mA
8 Port Networked PDU with Individual On / Off
19 "Rack Mount, 1U
User Interface via Web Browser with Password
Scheduled on / off per port
Programmable Sequential Power Up
8 x IEC C13 outputs, max. 10A - front mounted plug
2 x RJ45 Inputs for temperature and temperature / humidity sensor with alarm
1x Seriel Connection for control
8 x Watchdog with ping of each connected PC
SNMP Get / traps and e- mail support
Supports Iphone and Android
Relay box for switching on/off 2 x 230 VAC equipment via the network
Shows current power consumption and ambient temperature on PC.
Web server built-in - password-protected.
Time schedule - time table for switching on/off
Time table for on/off. 2 x 230VAC outputs
Track - 20 x 230 V outlet, built-in power consumption meter.
Can be cascaded with nine slaves.
Ethernet password. logo Email alert for exceeding limits and the errors
1-pole relay output - switcher L
Remote-controlled 230VAC power rail with on/off per output
1U 19" for rack mounting - rack bracket included
8 x 240VAC C-13 outlets
1 x C20 input plug. C-19 plug not included
Switch on / off Server via the network / Internet
User interface is via Web browser
Wi-Fi connection
Password protected
Supports iPhone and Android
Intelligent 8 ports Power Distribution Unit
Justerbar sekventiel tænd / sluk
Samlet strømovervågning
Samlet spændingsindgang
Outputovervågning
Total brugt kWh
Effektfaktorgenkendelse
Driftstemperatur: Op til +55°C
8 x låsbar IEC-C13 netudtag
120 - 240VAC
Styr op til 3 PDU slaver fra en master
1 x C20 16Amp
Sensor for temperatur- og fugtighedsalarm
Alarm for vand via infrarød sensor
Røgdetektor
Automatiske alarmmeddelelser
Temperatursensor til temperaturmåler med 2 meter kabel