Surplus: GSM/GPRS/GPS temp. overvågning
Inkl. 4 stk. temperaturføler + GPS modul
GSM controllers in this group are well suited for remote monitoring and control of facilities for mobile network equipment, vehicle monitoring, environmental monitoring and food control, etc.
GSM remote monitoring works over the mobile network . They use 2G and 3G (phase out), GPRS and 4G (LTE) and 5G. GSM controllers are not only used in places without Ethernet connection, but where the connection via the mobile network is...
GSM controllers in this group are well suited for remote monitoring and control of facilities for mobile network equipment, vehicle monitoring, environmental monitoring and food control, etc.
GSM remote monitoring works over the mobile network . They use 2G and 3G (phase out), GPRS and 4G (LTE) and 5G. GSM controllers are not only used in places without Ethernet connection, but where the connection via the mobile network is mandatory. Several GSM controllers have a built-in WEB server for easy setup, and do not need a special software. Some GSM controllers have MTM protocols such as HTTP record with XML / JSON status files, and HTTP API commands and both data collector and remote control, although they do not have public static IP address.
Some GSM controllers are set up using SMS commands. Some support email client with TLS encryption to send email alert under alarm conditions. Along with emails, the warning can also be sent as standard SMS. GSM controllers have standard analog inputs for DC voltage measurements, as well as digital inputs for contact monitoring and several have 1-Wire interface that supports up to 8 sensors.
Relays can be activated either remotely via SMS or HTTP API or locally.
HTTP content can be sent periodically or at previously set alarm conditions. This is very useful in client-server systems for GSM GPRS remote monitoring and control as part of SCADA computer systems.
Subcategories
There are 31 products.
Inkl. 4 stk. temperaturføler + GPS modul
2 x 230VAC power relay /16A – resistive load.
2 x DC switched outputs up to 40VDC/6A, also as PWM for LED, FAN, etc.
2 x independent inputs: 230VAC and up to 24VAC/24VDC, SMS alerts for power failure
SIM card and SD card
Backup battery (not included) as an option – Li-Ion 3.7V (14500)
Switch appliances on and off with SMS messages
GPRS M2M function, TCP/IP Get to directly send input status to Server
Get XML status from server to set device outputs.
Scheduled automatic switching on and off of appliances
Sends power failure warning and recovery.
Restarting appliances, such as servers.
Monitoring of 2 x A/D inputs AC/DC voltages with autodetect
4 x digital inputs DIN1, DIN2, DIN3, DIN4 for DC voltage.
Universal bus (1-wire) for temperature and humidity sensors.
Thermostat function.
Alarm function: Temperature alarm, Humidity alarm, A/D limits, DI change
Alarm in case of jamming of a GSM signal.
Up to 12 alarm numbers, each can be set for different events
Up to 1000 authorized users and 2 administrator numbers.
Bluetooth
All inputs are SO compatible
Vandal-proof and waterproof dome antenna
The LTE band 700-2700MHz (including GSM, 3G and 4G)
VSWR: <=1.5
Passive gain: 7-8 dBi
Polarization: Vertical
Nominal power: 50W
Input impedance: 50 Ohm
Cable length: 1.5 meters
Cable type: RG174
Connector type: SMA male
Weight of antenna: 57g
360° Omnidirectional
Center hole mounting
Global 4G LTE Controller, logger and alarm
Supports all LTE frequencies
Setup via USB, SMS and HTTP API
USB setup - use USB cable with Mini B male
2 digital "dry contacts". High on contact
2 analog inputs, 0 - 10VDC or 4-20mA input (10bit)
4 relay outputs, COM, NO and NC
1-Wire input for up to 8 Teracom sensors
1 x RS485 for max. 8 MODBUS RTU sensors
Data logger with 70,000 logs
Upload data to HTTP/HTTPS Post in XML/JSON
SMS alarm and Email alarm to 5 recipients
Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup.
10 to 28VDC, 370mA @ 12VDC - additional PSU
Dimensions: 158 x 119 x 34 mm
Weight: 470g
Temperature: -20 - +55°C
GSM/LTE alarm - 4G - Global version
Supports all LTE frequencies
Configuration via USB (Windows program) or SMS
2 x digital inputs with "dry contact" or "logic level" mode
2 x analogue input from 0 to 60VDC, 10 bits
2 x relay output with NO/NC contacts
1-Wire interface for 4 Teracom temperature and humidity sensors
Input can be navigated with alarm text etc.
SMS alarm - up to 5 numbers
Email alarm - up to 5 email recipients, SMTP with TLS support
1 relay can be activated with calls from up to 100 phone numbers
Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup.
MQTT 3.1.1 support
Firmware update "on air"
Supply voltage: 8 - 32VDC, 2Watt - purchase PSU
Dimensions: 109 x 65 x 32 mm
Weight: 152g
Water detector with normally closed relay output
Supply voltage: 5VDC / 10mA
Relay contact: max. 30VDC/500mA
Red: +5VDC
Black: GND
Green: Relay contact
White: Relay contact
REMEMBER: Relay contact opens when water is removed.
3,6 V/1200 mAh batteri til ca. 60 timers drift ved fuld opladet
Temperature gauge
1.8 Meter cable
Dallas DS18B20 Chip
Thermal sensor for mounting
Dallas DS18B20 Chip
5 Meters
Temperature sensor for mounting
10 m wire
Dallas DS18B20 Chip
With copper bracket for vertical mounting (M6, 6mm diameter mounting hole)
Measuring range: -10 to + 85 ° C Accuracy on +/- 1 ° C
Thermal sensor for mounting 3 meters
Sensor tip: stainless steel
Medium 3.0V - 5.5V supply
With new chip for each pin
BLUE pin: DATA
BLACK pin: GND
RED pin: VCC
1-wire (multiple to same pin)
1-wire communications - several sensors can be connected to the same unit
± 3.0% relative humidity accuracy
± 0.4% relative temperature accuracy
12 bit resolution for humidity measurement
14 bit resolution for temperature measurement
Calibrated digital output
Eksellent long-term stability
Each sensor has its own unique 64-bit serial number
Rain sensor for weather station and alarms
Pulse signal When tilt container is filled with water
Making short contact between the 2 wires
Cable length: 2.8 meters
Dimensions: 150 x 60.5 x 92 mm (L x B x H)
distance between mounting holes: 135 mm
1-Wire temperature / humidity sensor
3 wires. +3.3 - 5.5VDC, Gnd, Data (yellow)
Temperature: -40 - + 80°C
Humidity: 0 - 99%RH
Temp: +/-0.5°C
Humidity: +/-3%RH
Repeatability: ±1%RH, ±0.2℃
CPU: 720Mhz/ 4 Core/2GB/Linux v.5.10
10/100 ethernet connection
2 x USB to USB camera, USB FLASH, USB HUb
8 x Analog ports
32 x Digital inputs
8 x Isolated digital outputs max. 24Vdc, 15mA
2 x Relay (NC NO COM) max. 10A for AC, 9~30V for DC voltage
LTE slot modem (modem purchased separately)
1 x Audio-Video output & input
SBNP v1, v2c, v3
OpenVPN, SSL, HTTPS
DHCP, HTTP, DynDNS, SMTP, RADIUS, Syslog, NTP server, HTTP request
API
Notification E-mail, phone call, SNMP, WEB to SMS, SMS Link
Logging SD, USB Flash, E-mail, FTP
power supplies single/redundant 24-48Vdc, 230Vac (contact sales regarding versions)
Antenna for GPS, 2.4GHz WIFI, 4G, LTE
5MHz bandwidth
Screw mounting
4 meter cable
Temperature: -40 - +85℃
Full IP67 Waterproof
Multi-band 4G LTE Cat.1 controller, logger and alarm
Setup via USB, SMS and HTTP API
USB setup - use USB cable with Mini B male
2 digital "dry contacts". High on contact
2 analog inputs, 0 - 10VDC or 4-20mA input (10bit)
4 relay outputs, COM, NO and NC
1-Wire input for up to 8 Teracom sensors
1 x RS485 for max. 8 MODBUS RTU sensors
Data logger with 70,000 logs
Upload data to HTTP/HTTPS Post in XML/JSON
SMS alarm and Email alarm to 5 recipients
Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup.
10 to 28VDC, 370mA @ 12VDC - additional PSU
Dimensions: 158 x 119 x 34 mm
Weight: 470g
Temperature: -20 - +55°C
GSM / LTE alarm - 4G
Configuration via USB (Windows program) or SMS
2 x digital inputs with "dry contact" or "logic level" mode
2 x analog input from 0 to 60VDC, 10 bits
2 x relay output with NO / NC switches
1-Wire interface for 4 Teracom temperature and humidity sensors
Input can be navigated with alarm text etc.
SMS alarm - up to 5 numbers
Email alarm - up to 5 email recipients, SMTP with TLS support
1 relay can be activated with calls from up to 100 telephone numbers
Push mode - XML data is sent via HTTP Post to a remote server. Server response may include relay setup.
MQTT 3.1.1 support
Firmware update "on air"
Supply voltage: 8 - 32VDC, 2Watt - additional PSU
Dimensions: 109 x 65 x 32 mm
Weight: 152g