Remote control/Measurement/Alarm via GSM

GSM controllers in this group are well suited for remote monitoring and control of facilities for mobile network equipment, vehicle monitoring, environmental monitoring and food control, etc.

GSM remote monitoring works over the mobile network . They use 2G and 3G (phase out), GPRS and 4G (LTE) and 5G. GSM controllers are not only used in places without Ethernet connection, but where the connection via the mobile network is mandatory. Several GSM controllers have a built-in WEB server for easy setup, and do not need a special software. Some GSM controllers have MTM protocols such as HTTP record with XML / JSON status files, and HTTP API commands and both data collector and remote control, although they do not have public static IP address.

Some GSM controllers are set up using SMS commands. Some support email client with TLS encryption to send email alert under alarm conditions. Along with emails, the warning can also be sent as standard SMS. GSM controllers have standard analog inputs for DC voltage measurements, as well as digital inputs for contact monitoring and several have 1-Wire interface that supports up to 8 sensors.
Relays can be activated either remotely via SMS or HTTP API or locally.

HTTP content can be sent periodically or at previously set alarm conditions. This is very useful in client-server systems for GSM GPRS remote monitoring and control as part of SCADA computer systems.

Remote control/Measurement/Alarm via GSM
There are 31 products.
GSM control 2 relay out, 2xMOS output, 2x Analog 4x Digital inputs, 8x Temperature measurementIQTD-GS440

2 x 230VAC power relay /16A – resistive load.
2 x DC switched outputs up to 40VDC/6A, also as PWM for LED, FAN, etc.
2 x independent inputs: 230VAC and up to 24VAC/24VDC, SMS alerts for power failure
SIM card and SD card
Backup battery (not included) as an option – Li-Ion 3.7V (14500)
Switch appliances on and off with SMS messages
GPRS M2M function, TCP/IP Get to directly send input status to Server
Get XML status from server to set device outputs.
Scheduled automatic switching on and off of appliances
Sends power failure warning and recovery.
Restarting appliances, such as servers.
Monitoring of 2 x A/D inputs AC/DC voltages with autodetect
4 x digital inputs DIN1, DIN2, DIN3, DIN4 for DC voltage.
Universal bus (1-wire) for temperature and humidity sensors.
Thermostat function.
Alarm function: Temperature alarm, Humidity alarm, A/D limits, DI change
Alarm in case of jamming of a GSM signal.
Up to 12 alarm numbers, each can be set for different events
Up to 1000 authorized users and 2 administrator numbers.
Bluetooth
All inputs are SO compatible

$315.64
Item number GSM-IO-EN-F+
Physically in stock
8dBi LTE Omni antenna, 700 - 2700MHz. Center hole mounting. 1.5 meter cable

Vandal-proof and waterproof dome antenna
The LTE band 700-2700MHz (including GSM, 3G and 4G)
VSWR: <=1.5
Passive gain: 7-8 dBi
Polarization: Vertical
Nominal power: 50W
Input impedance: 50 Ohm
Cable length: 1.5 meters
Cable type: RG174
Connector type: SMA male
Weight of antenna: 57g
360° Omnidirectional
Center hole mounting

$143.47
Item number GSM-ANTOMNI8-LTE
Physically in stock
4G Global LTE alarm and remote control, M2M, Data logger, I/O with Digital and Analogue, 1-wire, Relay, MODBUS

Global 4G LTE Controller, logger and alarm
Supports all LTE frequencies
Setup via USB, SMS and HTTP API
USB setup - use USB cable with Mini B male
2 digital "dry contacts". High on contact
2 analog inputs, 0 - 10VDC or 4-20mA input (10bit)
4 relay outputs, COM, NO and NC
1-Wire input for up to 8 Teracom sensors
1 x RS485 for max. 8 MODBUS RTU sensors
Data logger with 70,000 logs
Upload data to HTTP/HTTPS Post in XML/JSON
SMS alarm and Email alarm to 5 recipients
Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup.
10 to 28VDC, 370mA @ 12VDC - additional PSU
Dimensions: 158 x 119 x 34 mm
Weight: 470g
Temperature: -20 - +55°C

$538.75
Item number TCG140-4G
On the way in
4G Global LTE alarm and remote control, Input: 2 x Digital, 2 x Analogue, 2 x Relay output, 1-wire for sensors, MQTT

GSM/LTE alarm - 4G - Global version

Supports all LTE frequencies

Configuration via USB (Windows program) or SMS

2 x digital inputs with "dry contact" or "logic level" mode

2 x analog inputs from 0 to 60VDC, 10 bits

2 x relay outputs with NO/NC contacts

1-Wire interface for 4 Teracom temperature and humidity sensors

Input can be navigated with alarm text etc.

SMS alarm - up to 5 numbers

Email alert - up to 5 email recipients, SMTP with TLS support

1 relay can be activated with calls from up to 100 phone numbers

Push mode – XML data is sent via HTTP Post to a remote server. Response from server may contain relay setup.

MQTT 3.1.1 support

Firmware update "over the air"

Supply voltage: 10 - 28VDC, 2Watt - optional PSU

Dimensions: 109 x 65 x 32 mm

Weight: 152g

$380.64
Item number TCG120-4G
On the way in
Effective server room monitoring: Temperature, Fire, Humidity, Voltage and digital alarms 4G LTE

CPU: 720Mhz/ 4 Core/2GB/Linux v.5.10
10/100 ethernet connection
2 x USB to USB camera, USB FLASH, USB HUb
8 x Analog ports
32 x Digital inputs
8 x Isolated digital outputs max. 24Vdc, 15mA
2 x Relay (NC NO COM) max. 10A for AC, 9~30V for DC voltage
LTE slot modem (modem purchased separately)
1 x Audio-Video output & input
SBNP v1, v2c, v3
OpenVPN, SSL, HTTPS
DHCP, HTTP, DynDNS, SMTP, RADIUS, Syslog, NTP server, HTTP request
API
Notification E-mail, phone call, SNMP, WEB to SMS, SMS Link
Logging SD, USB Flash, E-mail, FTP
power supplies single/redundant 24-48Vdc, 230Vac (contact sales regarding versions)

Call +45 56 66 20 20 for price
Item number REMOTE-MON
On the way in
TCG140-4E is a 4G LTE alarm and remote control, M2M, IOT, data logger, I / O with digital and analog, relay, Modbus

Multi-band 4G LTE Cat.1 controller, logger and alarm

Setup via USB, SMS and HTTP API

USB setup - use USB cable with Mini B male

2 digital “dry contacts”. High on contact

4 analog inputs, 0 - 10VDC or 4-20mA input (10bit)

4 relay outputs, COM, NO and NC

1-Wire input for up to 8 Teracom sensors

1 x RS485 for max. 8 MODBUS RTU sensors

Data logger with 70,000 loggings

Upload data to HTTP/HTTPS Post in XML/JSON

SMS alarm and Email alarm for 5 recipients

Push mode – XML data is sent via HTTP Post to a remote server. Response from server may contain relay setup.

10 to 28VDC, 370mA @ 12VDC - optional PSU

Dimensions: 158 x 119 x 34 mm

Weight: 470g

Temperature: -20 - +55°C

$402.60
Item number TCG140-4E
Physically in stock
4G LTE alarm and remote control, 2 x digital input, 2 x analog, 2 x relay output, 1-wire for sensor, MQTT

GSM/LTE alarm - 4G

Configuration via USB (Windows program) or SMS

2 x digital inputs with "dry contact" or "logic level" mode

2 x analog inputs from 0 to 60VDC, 10 bits

2 x relay outputs with NO/NC contacts

1-Wire interface for 4 Teracom temperature and humidity sensors

Input can be navigated with alarm text etc.

SMS alarm - up to 5 numbers

Email alert - up to 5 email recipients, SMTP with TLS support

1 relay can be activated with calls from up to 100 phone numbers

Push mode – XML data is sent via HTTP Post to a remote server. Response from server may contain relay setup.

MQTT 3.1.1 support

Firmware update "over the air"

Supply voltage: 8 - 28VDC, 2Watt - optional PSU

Dimensions: 109 x 65 x 32 mm

Weight: 152g

$323.84