A relay is an electrically operated switch. It consists of a set of input terminals for a single or multiple control signals and a set of operating contact terminals. Relays are used where needed by control and circuits at and independent low power signal, or where multiple circuits must be controlled by one signal. For example, if you Have a door you want to unlock for every gang man doing something, use a relay. You can choose whether the relay should be normally open (disconnected) or normally closed (user contact). This is very typical of a relay is NC (normally closed), as something must be done to disconnect the relay switch.
Thermostat 0 to 60°C Snap-Action switch Dimensions 60 x 33 x 43 Max. starting current AC 10 Max. switching capacity NC: 10 A resistive / 2 A inductive @ AC 250 V (Special specifiction are welcome)
Compact design Wide adjustment range DIN Rail mountable 35mm Thermostat 0 to 60 °C Snap-Action Contact Housing plastic, UL 94V-0, light gray Max. inrush current AC 16 A for 10 seconds Max. switching capacity NC: 10 A resistive / 2 A inductive @ AC 250 V, NO: 5A resistive / 2A inductive@250V 15A resistive/2A inductive@AC120V DC30W(DC24-72V) IP20 Dimensions 60 x 33 x 43
8 Potential-free relay outputs - 230Vac / 16 A, 24VDC / 10 A
Relay outputs are individually via HTTPS, SNMP or Command
Startup delay from 0 to 9999 seconds. Adjusted individually
Inrush Delay is set to 1 second
Programmable on / off sequence
Activating relays can be controlled from sensor or inputs
8 channel watchdog via ICMP / TCP Ping
8 signal entrances From NO and NC units, door contacts, etc.
Entrance to sensors Temperature, humidity and air pressure
Messages via e-mail, Sylog and SNMP Trap MQTT
Depending on thresholds for sensor measurement and signal input
LED display for overall power, IP address, sensor data and error reports
Android app and iOS app
DIN bracket
Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
2 x RJ45 Daisy Chain, only data is continued Further to Dual Watchdog
Operating temperature range: - 25 ~ + 75 ° C
I / O Pair Connection - Input Mirrors to another's output
8 x Power relay - electromechanical, COM NO
Rel becoming: On: 10ms, Off: 5ms
Relay Contact voltage and current: 24VDC / 250VAC / 5A
Electromechanical: Avoid inductive load
supply voltage: POE or 12 - 48VDC
12 channel power relay output module
RS485 to MODBUS
Communicates via MODBUS RTU
Operating temperature -25 ° -75 ° C
4 kV EFT protection
3 kV Surge Protection
for wall or DIN rail mounting
Each Channels Can be software programmed to be input or output
Software routines provided Easily Link to High Level Programs
Switch Selectable Interrupt Level (IRQ2 ... IRQ7)
Presentable de-bounce time in interrupt fashion
10k pull-up resistor for each channel