1-wire temperature and humidity meter 12 bit resolution when measuring moisture 14 bit resolution when measuring temperature Good long-term stability LED communication indicator Dimensions: 99 x 66 x 36 mm Weight: 70g
Modbus RTU (RS485) relay module with 4 outputs RS-485 interface supporting up to 63 nodes Non-volatile memory that retains relay status LED indicator for communication status Voltage supply: 5 - 28VDC Watchdog functionality for communication loss Isolated relay contacts Shrimp switch: 250VAC / 30VDC 3Amp No inductive load on relay contact Memory for saving settings Built-in 120 ohm termination resistor DIN rail mounting Firmware update via the interface Dimensions: 52 x 91 x 59 mm Operating temperature: -20 - +60°C
AC and DC voltage meter with true RMS Resolution: 24 bits 0-264VAC 0-60Hz (3 phases) L1, L2, L3, N 0-+/-370VDC Input impedance greater than 2.4Mohm Modbus RTU (2-wire RS485) Built-in RS485 termination (120 ohms) Up to 63 units per RS485 Bus LED for communication status Response time: less than 50mS Temperature: -20 - +60°C Supply voltage: 5 - 28VDC Dimensions: 86 x 59 x 35 mm
Global 4G LTE Controller, logger and alarm Supports all LTE frequencies Setup via USB, SMS and HTTP API USB setup - use USB cable with Mini B male 2 digital "dry contacts". High on contact 2 analog inputs, 0 - 10VDC or 4-20mA input (10bit) 4 relay outputs, COM, NO and NC 1-Wire input for up to 8 Teracom sensors 1 x RS485 for max. 8 MODBUS RTU sensors Data logger with 70,000 logs Upload data to HTTP/HTTPS Post in XML/JSON SMS alarm and Email alarm to 5 recipients Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup. 10 to 28VDC, 370mA @ 12VDC - additional PSU Dimensions: 158 x 119 x 34 mm Weight: 470g Temperature: -20 - +55°C
GSM/LTE alarm - 4G - Global version Supports all LTE frequencies Configuration via USB (Windows program) or SMS 2 x digital inputs with "dry contact" or "logic level" mode 2 x analogue input from 0 to 60VDC, 10 bits 2 x relay output with NO/NC contacts 1-Wire interface for 4 Teracom temperature and humidity sensors Input can be navigated with alarm text etc. SMS alarm - up to 5 numbers Email alarm - up to 5 email recipients, SMTP with TLS support 1 relay can be activated with calls from up to 100 phone numbers Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup. MQTT 3.1.1 support Firmware update "on air" Supply voltage: 8 - 32VDC, 2Watt - purchase PSU Dimensions: 109 x 65 x 32 mm Weight: 152g
Web based Data collector module with built-in WebServer Supports MQTT 3.1.1 protocol 4 x digital input Dry - external contact without voltage 4 x analogue inputs with 0 to 10VDC, 0-20mA 4 x powerful relay outputs with NO/NC contacts RS485 port MODBUS RTU up to 24 registers (sensors) Modbus TCP/IP support Data logger with memory for 70,000 logs SNMP v3 support with trap alarm 4 pcs. schemes for real-time control of relay Up to 24 independent alarms Secure email XML/JSON and HTTP API commands for client-server Dynamic DNS support for DynDNS, No-IP and DNS-O-Matic NTP time sync Supply voltage: 10 - 32VDC - purchase PSU Dimensions: 145 x 90 x 40 mm
1-wire communications - several sensors can be connected to the same unit
± 3.0% relative humidity accuracy
± 0.4% relative temperature accuracy
12 bit resolution for humidity measurement
14 bit resolution for temperature measurement
Calibrated digital output
Eksellent long-term stability
Each sensor has its own unique 64-bit serial number
1-wire Temperature / Humidity sensor Temperature -20 - +60°C Humidity 10 - 90% RH Temp tolerance +/-0.4°C at -10 - +60°C Moisture tolerance ±3.0%rH at 20 - 80%rH Long term operation ±0.25%/year at 20 to 80%rH Long-term operation ±0.05°C/year at -10 to +60°C Solution 0.1 %rH 0.1 °C Power supply/consumption 4.0 to 5.5 VDC 5 mA Dimensions 62 x 28 x 16 mm Cable length 1 m
Temperature and humidity sensor 1-wire interface for Teracom controller Temperature: +/-0.4 °C (-10 to +60 °C), max. +/-0.6°C Resolution: 0.1°C Humidity: +/-3.0% RH (20 - 80% RH), max. +/-5% relative humidity Solution: 0.1% RH Supply voltage: 4.5 - 26VDC LED indicator for communication status Long-term stability based on digital signal processing Changeable bit rate and other communication parameters Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g
Multi sensor for CO2, Temperature and Humidity Interface: RS485 - MODBUS RTU LED indicator for status of communication Long-term stability based on digital signal processing Self-calibration on fresh air for CO2 measurements Changeable communication parameters Non-volatile memory for all settings Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g Supply voltage: 4,5 - 26VDC / Max. 150mA
Temperature and Humidity sensor RS485 MODBUS RTU Temperature: +/-0,4 °C (-10 to +60°C), max. +/-0,6°C Resolution: 0,1°C Humidity: +/-3,0% RH (20 - 80% RH), max. +/-5% RH Resolution: 0,1% RH Supply voltage: 4,5 - 26VDC LED indicator for status of communication Long-term stability based on digital signal processing RS-485 interface (2-wire) carrying up to 32 nodes Changeable bitrate and other communication parameters Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g
Multisensor for CO2 and barometric pressure Interface: 1-wire (+/- and data) LED indicator for communication status Long-term stability based on digital signal processing Self-calibration on fresh air for CO2 measurements Interchangeable communication parameters Non-volatile memory for all settings Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g Supply voltage: 4.5 - 26VDC / Max. 150mA
Multi sensor for CO2 and Barometric pressure Interface: RS485 - MODBUS RTU LED indicator for status of communication Long-term stability based on digital signal processing Self-calibration on fresh air for CO2 measurements Changeable communication parameters Non-volatile memory for all settings Firmware update via the interface Size: 81 x 81 x 30 mm Weight: 66g Supply voltage: 4,5 - 26VDC / Max. 150mA
1-wire Combi Sensor
Temperature: -20 - +60 ° C +/- 0.6 ° C
Resolution: 0.1 ° C
Humidity (Moisture): 5 -95% Rh +/- 5%
Resolution 0.1%Rh
IP54 Plastic housing, very sturdy
Up to 8 sensors on the same 1-wire
16 bits at temperature
12 bits at moisture
Supply Voltage: 4.5 / 25mW
Dimensions: 74 x 66 x 36 mm
Data logger for external temperature and humidity sensors Sensors are not included - must be purchased separately, see selection Memory for 70,000 measurements Temperature, humidity and dew point can be displayed graphically 1-Wire and RS485 sensor interface Up to 8 Teracom sensors can be connected MODBUS TCP/IP support SNMP v2 with trap alarm for 5 email recipients Secure email XML/JSON and HTTP API commands for client-server Dynamic DNS, DynDNS, No-IP and DNS-O-Matic NTP support for time synchronization Remote firmware update Supply voltage: 10 - 32VDC - purchase PSU
Open board til smart temperatur- eller fugt måling and styring
Password beskyttet Web baseret konfiguration og kontrol
1 x digital input med “dry contact” og “logic level” mode
1 x analog input fra 0 til 60VDC
1 relæ output med NO/NC kontakter
1-Wire input til 1 temperature eller fugtmåler
SNMP v.1 support
SNMP traps ved alarm
E-mail udsendelse ved alarm
SMTP med godkendelse (SSL/TLS er ikke supporteret)
HTTP og XML API kommandoer
Remote FTP firmware update.
Multi-band 4G LTE Cat.1 controller, logger and alarm Setup via USB, SMS and HTTP API USB setup - use USB cable with Mini B male 2 digital "dry contacts". High on contact 2 analog inputs, 0 - 10VDC or 4-20mA input (10bit) 4 relay outputs, COM, NO and NC 1-Wire input for up to 8 Teracom sensors 1 x RS485 for max. 8 MODBUS RTU sensors Data logger with 70,000 logs Upload data to HTTP/HTTPS Post in XML/JSON SMS alarm and Email alarm to 5 recipients Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup. 10 to 28VDC, 370mA @ 12VDC - additional PSU Dimensions: 158 x 119 x 34 mm Weight: 470g Temperature: -20 - +55°C