HMI 2.8" Controller Panel with Touch Display
Til mindre styringsopgaver, med TFT display og touch
In this category you will find our analog and digital I / O modules. And a lot of other things including temperature sensors, Smart I / O modules, PLC and protocol converters. See blah. our 3 channel Quadrature counter with encoder for measuring eg. distance traveled.
Subcategories
There are 262 products.
Til mindre styringsopgaver, med TFT display og touch
Measures: -20 ~ + 60 ° C and 0 ~ 100% RH
Accuracy: ± 0.4 ° C; ± 3.0% RH
LCD display shows the temperature, humidity, dewpoint and
module ID
10 ~ 30 VDC power input
IP66 Waterproof
Data Logger
Memory for temperature and 4,088 humidity records
RS-485 communication interface
DCON or Modbus RTU
Built-in Web server
Logical functions with IF-THEN-ELSE setting
IF-THEN-ELSE for simple set of conditions
No more programming. Just click and finished
Supports I / O, counter, timer, calendar, e-mail, rules
Data Logger and data files supported rewind feature
Modbus TCP / RTU protocol for SCADA software seamless integration
I/O-Board XW with inputs and outputs
Supports I-7000 Remote I / O modules (up to 16)
Supports Modbus RTU slave units (up to 10)
SNTP time synchronization supported
Support SMS (GSM: Quad-band 850/900/1800/1900 MHz)
Supply voltage: 12 - 48VDC
8 digitale ind- og udgange Udvidelsesmoduler til L-CON-LOG serien
8 digitale isolerede ind- og udgange Udvidelsesmoduler til L-CON-LOG serien
Intelligent Controller with Web Server
Logical functions, such as: IF-THEN-ELSE
No programming. Just select, click and finish
Supporter: I/O module, counter, hour, e-mail
Modbus / TCP protocol for SCADA software Seamless integration
IEEE 802.3af compatible power over Ethernet ( Poe)
1 x RJ45 - 100Mbit Ethernet
7 x Analog input: 0 - +/-2.5V, 0 - 20mA (ext. Resistors)
A/I Resolution: 16bit
10 Samples per Second
A/I Also to Thermocouller: J, K, T, E, R, S, B, B, C, L, M, LDIN43710
6 x Digital Output: 0 - + 50VDC / 700mA Open Collector
Supply voltage: POE or 12 - 48VDC / 4.5Watt
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I/O module, counter, timer, email
Modbus/TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet
8 x Power relay output, COM NO
Relay switch: 30VDC, 250VAC 5A, only resistive load
Supply voltage: PoE or 12 - 48VDC / 5.5Watt
1 x RJ45 - 10/100 Base-TX Ethernet
Can be powered from a PoE
Integrated Web Server Setup
Logical functions with IF-THEN-ELSE
Rules, I / O, CGI counter, Timer, etc.
Email setup via Web browser
Modbus / TCP Protocol to 6 x Digital input (Wet Contact - external voltage for High)
Digital input has 16 bits counter
6 x Relay Power Output: 5A at 30VDC / 250VAC
Power over Ethernet (PoE) or an external DC power supply
Supply voltage: PoE or 12 - 48VDC / 5Watt
temperature range -25 ° C ~ + 75 DEG C
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I / O module, counter, timer, email
Modbus / TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet
7 x Temperature sensor inputs (differential)
2/3-wire Pt100, Pt1000, Ni120, CU100, Cu1000
A/I resolution: 16bit
12 samples per second (Total)
Individual sensor configuration
Power supply: PoE or 12 - 48VDC / 4.5Watt
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I / O module, counter, timer, email
Modbus / TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet
16 x Digital input: Wet: 0 - + 50VDC
D / I count: 16bit, 50Hz
Power supply: PoE or 12 - 48VDC / 4.5 Watt
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I / O module, counter, timer, email
Modbus / TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet to 6 x Analog input: 0 - +/- 10V, 0 - 20mA
A / L solution: 16bit
2 x Analog output: 0 - +/- 10V, 0 - 20mA
A / O resolution: 12bit
2 x Digital outputs: 0 - + 50VDC / 700mA Open Collector
2 x Digital input: Dry / Wet: 0 - + 30VDC < br> D / I count: 16bit, 50Hz
Power supply: PoE or 12 - 48VDC / 4.5Watt
1 A/D indgang til vejecelle,
1 D/A udgang
4 digitale udgange
20 channel analog input module for RS485 Bus
16bit resolution
20 Single Ended inputs (common frame) - Only for Volt
10 differential entrances for volts about power
10 measurements per second (Total )
Jumper Setting in the module
Supply voltage: 10 - 30vdc / 1.3 watts
Dim: 123 x 72 x 35 mm
DIN bracket
RS485 Module for load cells
2 analog inputs for 4 wire load cell,
1 excitation Exit
1 Digital input
4 digital outputs
Supply: 10 - 30VDC
RS485 Module for measuring voltage and power
is with 15VDC transmitter output for power loop
1 x analog input 0-20MA, 0 - +/- 10V
1 x digital input. High is closed Contact
2 x Digital output (Open Collector) + 50VDC / 30mA
Supply voltage: 10 - 30VDC
Dim: 123 x 72 x 35 mm
8 channel analog input module for RS485 Bus
16bit resolution
10 measurements per second (total)
for current measurement - shunt with 125 ohm resistance
Supply voltage: 10 - 30vdc / 1.3 watt
Dim: 123 x 72 x 35 mm
with your bracket
RS485 Module for temperature sensors
1 x input for 2-, 3- or 4-wire PT100,Pt1000 sensor
Nickel Temperature sensor
Supply voltage: 10 - 30vdc
Module for PT100 or PT1000 sensor with 4-, 3- or 2-wire
for nickel temperature sensor (Ni RTD)
16 bit resolution
15 Measurements per second (Total)
Supply voltage: 10 - 30vdc / 1 Watt
Master RS485 must establish bias voltage
Dim: 123 x 72 x 35 mm
Power or Voltage Output
0 - +10VDC, 0 - 20mA, 4 - 20mA
Resolution: 12-bit
Software Selectable Power or Voltage Output
Output Cable Detector for Power Output (4 - 20mA)
Backlink Voltage or Current
Configurable Power-on Value
Configurable Safe Value
3000 VDC Intra Module Isolation
Programmable Output Slope
Dual Watchdog
Temperature Range: -25 to +75°C
RS485 module with 4 analog outputs
0-20mA or 0 - +/- 10V
D / A response time: 10ms
Resolution: 14bit
Supply voltage: 10 - 30vdc
RS485 Slave module with 8 digital inputs
6 pcs. Balanced
2 pcs. With joint GND.
Sink and Source Inputs
16 Bit Counter
RS485 Bus
Supply voltage: 10 - 30VDC
Dim: 123 x 72 x 35 mm
RS485 Module with 16 digital inputs
inputs are Dry Contact - High at contact to GND
RS485 The module is slave
supply: 10 - 30vdc
DIN bracket
RS485 Module - Slave, with digital input
8 x digital inputs for DC and AC
Voltage monitoring
input voltage: 80 - 250VAC / DC
Supply: 10 -30vdc
8 digital contact inputs
8 digital outputs "Open source" from joint terminal
RS485 interface
DIN bracket
screw terminal
8 digital outputs and 4 digital inputs
Open Collector Output
Photocouple Isolation
Digital input channels can be used as 16-bit counters
Configurable Power-on Value settings
Configurable settings for sure value
3750 Vrms insulation voltage
Dual Watchdog
Wide operating temperature range: -25 to + 75 ° C