Active Rod antenna Atomic Time
Accessories
DCF 77 kHz rod antenna w/5 meter cable
For ATOMUR-SAT-T+
Must be mounted horizontally (landscape)
Must face south (Frankfurt, Germany)
Is sensitive to EMC noise which can interfere with reception
NTP Server - Atomic clock for 19 rack mounting.
Signal from DCF77 in Frankfurt (77.5kHz).
Rod antenna with 5 meter cable with BNC male
Additional antenna cable 50 ohm, BNC male/male
Purchase BNC-SAMLE
With network port and serial port
1U for rack mounting
Power is supplied from 230VAC.
ATOMUR-PRO19 has an external antenna and can be used in places where there are otherwise problems with receiving the signal. ATOMUR-PRO19 can be installed as an SNTP server so that Servers/Clients can retrieve the time via the network. All models receive the DCF77 radio signal at 77.5 KHz from Frankfurt. The range is approx. 2000 km.
Connects to a serial port 9600 bps or network port 10/100 Mbit
Shows time and date on a display as well as reception conditions using a series of LEDs.
Power supply: Has a built-in 230 VAC power supply
Distance from receiver to PC: Can be extended on the BNC connector (antenna port) by up to 2 x K-ATOMUR+50 (RG174U cable á 50 m, 50 ohm) – a total of 100 m.
Software: Windows 2000, XP, 2003, Vista 32/64 and Win 7 as well as Linux using the serial port.
Accessories
DCF 77 kHz rod antenna w/5 meter cable
For ATOMUR-SAT-T+
Must be mounted horizontally (landscape)
Must face south (Frankfurt, Germany)
Is sensitive to EMC noise which can interfere with reception
Forlængerkabel til DCF antenne, 50 meter
The ideal choice for Server Room and Server rack monitoring.
4 x potential-free switching relay outputs - 36VDC / 3A switches
Large LED display for power measurement, IP address, sensor data and error reports
4 x Watchdog for monitoring connected PCs (ICMP / TCP)
12 x passive signal inputs - (contact inputs) for Phoenix plugs
4 x RJ45 for temperature / humidity sensors. RS232 / 485, 1 x RJ45 for LAN
Features, limit values, alarm receivers set up on the device via supplied software
2 x 12VDC power supply inputs (redundant)
PoE - Power over Ethernet for 2111-2 the model.
Free APP for Android and iPhone
SNMP Get / Traps (SNMPv1, v2c, v3)
Atomur- controlled GPS time server to the network 32
channel receiver which reduces the risk of signal loss
TCXO (Temperature Compensated X-tal Oscillator) in order to keep the time in the absence of GPS signal
10 / 100BaseT redundantly Ethernet
Low power consumption only 7W
230VAC 50-60Hz 0.1A
Operating temperature 0 to 50 °
Supplied with multi-antenna, wall mount and 30 m RG58 aerial cable
Bypass-Switch til udskiftning eller vedligeholdelse af uafbrydelige strømforsyninger (UPS)
19" rackmontering, 1U
Synlig LED-Display
1 output „zur USV“ IEC C19, 16A
1 input „von USV“ IEC C20, 16A
6 x IEC C13 udgange 10A
1 x IEC C20 16A Strømforsyning
Lavt internt strømforbrug
20 ports PDU with individual and total power meters via network
Integrated residual current measurement type A
User interface via web browser with Password
16 x IEC C13 outputs 10A
1 x RJ45 to LAN and 1 x RJ45 for sensor, temperature, moisture, hPascal
4 x Schuko outputs 16A
SNMP Get / traps and email support