Transient protection of network. Up to 100 / 1000mbit. RJ45 in and out. DIN bracket
Surge Protection to Gigabit network
Max. Working voltage on line: 48V
2KV Impulse protection (10/700 Micro sec)
Loss Factor: 0.2dB
Dim: 112 x 38 x 30 mm
Isolator for 1000 Mbit network, one port
Insulation on all 4 pairs.
Transient protector - Remember the earth connection (screw)
2 x RJ45 female
Max. Discharge current (fine LL): 40A (8/20 microSec)
Max. Discharge current (coarse LE): 2.5 kA (8/20 microSec)
Residual voltage: <5V (1.2/50 microSec)
Hi-Pot (Pri to Sec) isolation: 1500Vrms, 1mA, 60 seconds
Cannot transmit PoE
Dimensions: 72 x 50 x 25 mm
Galvanic network isolation. Provides optimal protection with galvanic isolation between input and output.
Transient protection up to 40Amp for 20micro seconds.
Surge Protection to Gigabit network
Max. Working voltage on line: 48V
2KV Impulse protection (10/700 Micro sec)
Loss Factor: 0.2dB
Dim: 112 x 38 x 30 mm
RJ45 two RJ45 Thunder Protector (IP only)
Thunder Protector protect two lightning over-voltage
Surge Over-voltage and electrostatic discharge.
Maximum discharge current 10KA
Aluminum Case with two RJ45 Port
Transient protection for 10/100 Mbps network
4kV to ground.
2 x RJ45 female
Ground wire is to be connected.
PoE surge protection for 10/100/1000Mbit networks
Supports PoE voltage 48VDC / 40Watt
Nominal discharge: 2.5kA, max. 5kA (8/20myS)
Response time: less than 1ns (nano-second)
Transmission loss: below 0.2dB
2 x RJ45 female (in / out)
Protected pin: 4/5, 7/8 (power supply + data), 1 - 8 (data)
Operating temperature: -40 - +70°C
Humidity: less than 90% rh
Dimensions: 93 x 55 x 35 mm
Weight: 73g
DIN bracket
Ground cable of more than 2.5kv must be shorter than 1 meter
Ground cable thickness: Min. 2.5 sq.mm
Ground resistance must be less than 4 ohms
Nothing can protect against a direct lightning strike