Temperature and humidity Sensor for T&D Datalogger Model LOG-WL5XX series
Temperature and moisture feel to log-wl5xx
Monitoring of premises, storage rooms, server rooms, installations, machines, refrigerators, freezers, food shuttles and the like, the DANBIT Datalogger modules are a good choice. Measurement and logging of temperature, humidity, atmospheric pressure, carbon dioxide, voltage or current are all with date and time stamp.
Measurement data can be displayed on a computer as graphs and values and can be exported as a csv file for...
Monitoring of premises, storage rooms, server rooms, installations, machines, refrigerators, freezers, food shuttles and the like, the DANBIT Datalogger modules are a good choice. Measurement and logging of temperature, humidity, atmospheric pressure, carbon dioxide, voltage or current are all with date and time stamp.
Measurement data can be displayed on a computer as graphs and values and can be exported as a csv file for statistical processing and report printing.
DANBIT A / S is a sole distributor of T & D Datalogger of very high quality, from Japan's largest manufacturer of compact units for measuring and recording temperature, moisture, voltage and pulses.
The data logger is battery powered, very robust, waterproof and for installation without cable routing. The data logger can be included in a permanent monitoring system or temporarily placed in a location where monitoring is desired. T & D offers data logger products, where measurement data and graphs can also be displayed on Smartphones.
Subcategories
There are 96 products.
Temperature and moisture feel to log-wl5xx
Datalogger til fugt, temperatur og CO2 måling
Modbus RTU Master or Slave
RS485
Memory: 4GB
DIN rail Mounting
Supply voltage: 8 ~ 24VAC / 12 ~ 35VDC
Power consumption: 3.5W
galvanically isolated
Software for Windows included
Integrar Web server
1-axis vibration measurement
Frequency range: 10 Hz to 1K Hz
Amplitude range: ±8g
Data Format:
Acceleration(mg): RMS, Maximum, P-P
Velocity(mm/s): RMS
Top 10 spectrum values(Amplitude/Frequency)
Crest Factor
Supported Modbus RTU Slave protocol
Size: 51 x 30 x 19mm
Supply voltage: 10 - 30VDC
Temp: -25 - +75°C
Multi input data logging for up to 70000 login
10/100 Mbit Ethernet
Password protected, web-based configuration and control
4 digital inputs, compatible with S0 pulse interface
6 analog inputs with 0 / 10V and 0 / 20ma
Modbus RTU interface for up to 24 sensors (registers)
Up to 24 channels for monitoring
Up to 24 Independent Alarms
SNMP V.2 Support - SNMP Trap - Alarm Alerts
HTTP and SNMP port change - HTTP API commands
Periodic HTTP post of XML / JSON Status files for client server systems
Modbus TCP / IP support
Dynamic DNS with dynns, no- IP and DNS-O-MATIC Support
NTP protocol support
supply voltage: 10 to 32V DC
Impulse and voltage logger with cable shoe cable
cannot be included in TD white series
Pt100 transmitter from sensor to 4-20mA
Working voltage: 24VDC
Accuracy: +/- o.2% full scale
Temperature range: -50 - +200°C
Dimensions: Ø45 mm
Plastic
Weight: 25g
Clamping: Center hole
Zero point adjustment
Adjustment of amplitude
Pt100 sensor 2 m Cable
100 mm Steel Tips
3.2 mm Diameter
Power supply for LOG-WL500GSM
100 - 230vac for 6VDC
Cable length: 1.8m
Connector: Power Jack 3.5 / 1.3mm
Remote-controlled 230VAC power rail with on/off per output
1U 19" for rack mounting - rack bracket included
8 x 240VAC C-13 outlets
1 x C20 input plug. C-19 plug not included
Switch on / off Server via the network / Internet
User interface is via Web browser
Wi-Fi connection
Password protected
Supports iPhone and Android
Very useful tool for servicetekinikeren
Target for consumption on the USB port is borderline.
Portable USB voltmeter with LCD display
3-7V / 50-3500mA / 0-19999mAh < br> Voltage Tester and leave
USB2.0 interface
The motion sensor light detection, temperature sensor for energy management
Connects energy management, local-lighting control via RS485 port
With powerful built-in relay for simple light activation 250VAC (1500 Watt T8 )
360 ° motion detection - up to 8 m in diameter and 4 meters height
Time delay / Sensitivity is adjustable
temperature sensor, - measuring the room temperature or fire alarm
Relay output to turn on the light via the PIR / light-strength and temperature sensors
RS485 2-wire communication bus
DCON and Modbus RTU protocols
ceiling surface mounted design
Supply voltage: 10 - 30VDC ca. 2W
Dimensions: Ø121 x 52 mm | IP20
Air quality tester that can show if there is gas in the air.
Can be used as a MODBUS RTU sensor, the host can be accessed via RS-485.
RS485 / RS422 / RS232 Master Gateway to Meter-Bus Slaves (sensors, actuators, etc.)
Supports up to 100 Meter-Bus meters (slaves)
MODBUS RTU function codes: 0x03 and 0x04 readdata
Selection of serial port, only one can be selected to be active
Baud rate x 2 (M-bus and COM port can be selected at different speeds)
Baud rate M-bUS: 300-2400 bps
Baud rate COM port: 300-115200 bps
Transparent data - no protocol conversion
M-BUS connection, 2-wire, max. 350meter.
Greater distance up to 5km requires a number M-bus repeaters
Supply voltage: 10 - 30VDC, 1.8 - 12Watt
Dimensions: 122 x 72 x 33 mm
Removable terminal blocks
Operating temperature: -25 - + 60°C
DIN mount
Robust plastic case
RS485 / RS422 / RS232 converter for Meter-Bus meters, actuators, etc.
Supports up to 100 Meter-Bus meters (slaves)
Selecting the serial port, only one can be selected to be active
2 x Baud rate (M-bus and COM port can be selected at different speeds)
Baud rate: 300 to 115,200 bps
Transparant data - no protocol conversion
M-bus connection is 2-wire , max. 350meter.
larger distance up to 5km requires a number of M-bus repeaters
Supply voltage: 10 - 30VDC, 1.8 - 12Watt
Dimensions: 122 x 72 x 33 mm | Removable terminal blocks
Operating temperature: -25 - + 75 ° C
DIN bracket
Robust plastic housing
USB LOG Mxxx Device Server for data acquisition
Connects LOG Mxxx data loggers to Ethernet
Transferring Log data to PCs with LOG SiteView SW
Real-Time Data-view
Supports transfer via Internet and Ethernet
Up to 5 LOG Mxxx can be connected via USB HUB
Up to 5 clients can receive LOG data while
access is password protected
Powers LOG Mxxx with excitement
Dimensions: 110 x 100 x 38 mm
Supply voltage: 12VDC / 1A (PSU is included)
Dataopsamler med USB og forstærkerfunktion
Kun til T&D Dataloggere
16-bit strain gauge / weighing bridge amplifier - datalogger
With temperature compensation
Excitation sense 2.5VDC
Bridge input: +/- 8mV Version: 16mV and 32mV
4 Megabyte memory to log data
USB and RS232, automatic baud rate up to 115.2kbit
Programmable input ranges (0-2 VDC, 0-20 VDC)
Battery operation - 10 year battery
Acc.: Software to configure, download, plotting, analysis and an alarm (not supplied)
Configurable alarm controls
Measurement speed of from 20 milliseconds (channel 1) to 12 hours
Robust aluminum housing
coated printed circuit board for protection against moisture, corrosion