Advanced Controller with logging
With slot for internal I/O expansion module, A/D, D/A, D/I, D/O, relay
Program with simple logic functions - WISE (Web Inside Smart Engine)
Logic functions with IF-THEN-ELSE logic
Supports SNMP, SMTP, FTP, MQTT, Modbus / TCP / RTU and DCON
Ethernet 10/100 / 1000Mbit
Setup via the built-in Web server
1 x RS232 port
2 x RS485 port
Supply voltage: 12 - 48VDC
The logger / controller with socket for internal I/O expansion bus (eg. Relay module)
is programmed with simple logic functions
IF-THEN-ELSE, AND and OR simplifies the setup
supports SNMP, SMTP , FTP, Modbus RTU and DCON
Ethernet 10/100/1000Mbit
setup via the integrated Web server
2 x RS232 ports
2 x RS485 ports
Built-in Web server Logical functions with IF-THEN-ELSE setting IF-THEN-ELSE for simple set of conditions No more programming. Just click and finished Supports I / O, counter, timer, calendar, e-mail, rules Data Logger and data files supported rewind feature Modbus TCP / RTU protocol for SCADA software seamless integration I/O-Board XW with inputs and outputs Supports I-7000 Remote I / O modules (up to 16) Supports Modbus RTU slave units (up to 10) SNTP time synchronization supported Support SMS (GSM: Quad-band 850/900/1800/1900 MHz) Supply voltage: 12 - 48VDC
ARM Cortex - A53 CPU , 1.2 GHz
RAM 1Gb SDRAM
16GB of memory
2 x RS232/422/485
8 x DI and 4 x relay outputs
DC input 9-32V
4G module
OS : Linux Raspbian
User need knowledge of linux and programing
Documentation for DI/O and 4G module
The logger / controller with socket for internal I / O expansion bus (eg. Relay module)
is programmed with simple logic functions
IF-THEN-ELSE, AND and OR simplifies the setup
supports SNMP, SMTP , FTP, Modbus RTU and DCON
Ethernet 10/100 / 1000Mbit
setup via the integrated Web server
1 x RS232 ports
1 x RS485 ports
Supply voltage: 12 - 48VDC
Multifunction concealed board
with 4 x AI, AO x 2, 4 x DI, 4 XDO
individual channel configuration
Jumper selectable voltage- or current input
Broken kabeldetektion by current measurement
Configurable settings for the initial value
digital input channels can be used as 32-bit counters
120 VDC surge protection to the analog input
60 VDC surge protection for digital input
Overload protection for digital output
Short circuit protection for digital output
Built-in module with screw terminals
5 x digital inputs, Wet Sink / source. 0 - + 50VDC
All inputs are with 32bit counter
2 x relay outputs 30VDC / 2A to 4 x 35 VDC relay outputs 6A, 6A
Relays 250VAC is non-inductive load
Insert module for L-Con log series
4 x differential analog inputs 4 - 20mA
or 8 single-ended analog inputs 4 - 20mA
Resolution: 12bit
Sample Rate: 4khz
2 x Analog Output 4 - 20mA
Resolution: 12bit
3 x Digital Input (DRY) - Contact to GND
3 x Digital Outout (Open Collector) + 40VDC / 200mA per port
Dim: 82 x 66 x 13 mm
with screw terminal block
Measures: -20 ~ + 60 ° C and 0 ~ 100% RH
Accuracy: ± 0.4 ° C; ± 3.0% RH
LCD display shows the temperature, humidity, dewpoint and
module ID
10 ~ 30 VDC power input
IP66 Waterproof
Data Logger
Memory for temperature and 4,088 humidity records
RS-485 communication interface
DCON or Modbus RTU
The integration module with screw terminal
8 x digital inputs 0 - + 50VDC
All inputs with 32 bit counter (50 Hz)
8 x digital outputs, the Open Collector + 50VDC 700mA / channel