Network-based device for switching on/off 230 VAC equipment.
Web server built-in - password protected
Can ping a stable IP address and if there is no response - turn equipment off and on
Timetable for on and off - scheduler
Mains socket is SCHUKO
The power supply for 230 VAC devices can be controlled with the NPOWER1+ which is inserted between the power supply and the device. From any PC on the local network (or over the Internet), the relay in the NPOWER1+ can be switched on and off.
The device is operated by entering the IP address of the NPOWER1+ in a Web browser, after which a built-in homepage (web server) appears. It can possibly be used to restart equipment that may be locked, such as routers and PCs. In this way, it is easy to restart, for example, a locked server and with the Watchdog timer function an ADSL cable modem or router, if it does not receive a response from the Internet.
Remote control of 230 VAC supply via local and internet.
10/100 Mbit Ethernet connection with RJ45 connector.
Supports HTTP, TCP/IP, SNMP, DHCP, DDNS and NTP protocols.
NOTE: Rebooting equipment or turning it on/off via the Internet requires a known IP address - either a fixed one or you can use Dynamic DNS (DDNS). This requires that the router supports DDNS, which works in such a way that the router contacts the DDNS provider (e.g. dyndns.dk) and provides its current dynamic IP address, after which the DDNS server associates the dynamic IP address with a fixed web address, e.g. "minkonto.dyndns.dk" or "www.mitdomæne.dk/npower1". To use this function, an account must be created with dyndns.dk or other DDNS providers.
It also requires that the selected port in NPOWER1+ be forwarded to NPOWER1+'s internal IP address in the router.
IEC 320 C14 Male Plug to European CEE 7/7 3Pin Female Socket Power Cord , C14 to EU SCHUKO PDU UPS Cable, 1.8 meter
The indoor light-gauge, temperature and humidity sensor 3 in 1
For energy optimization and building automation systems
Measuring range of illumination: 0 to 20,000 lux
Temperature Range: -20 to + 60 ° C
humidity Measuring range: 0 to 100% RH
Supports DCON and Modbus RTU / TCP protocols
Supports MQTT protocol Ethernet interface
With RS485 / RJ45 Ethernet communications interface
Relay output - 6 Amp @ 250VAC
Power supply: PoE and 10 - 48VDC, ca. 2 Watt
Operating temperature: 0 - + 75 ° C
web configuration and firmware update via Ethernet
Ceiling Mounting
Network operated relay box for switching on/off 230 VAC equipment
Shows current power consumption and ambient temperature on PC.
Web server built-in - password-protected.
With IP ping to stable website, it checks network outage.
If there is no response, it turns OFF/ON the desired external equipment.
ON/OFF can be controlled remotely from the browser.
Scheduled ON/OFF
HTTP, TCP/IP, DHCP, DDNS, SNMP v1, SMTP, NTP
Event and schedule controlled switching 230VAC/10A
Accurate current measurement
Input for 2 sensors - temp/humidity, pressure
RJ45 to Ethernet
NTP function
Power port on/off via HTTP(S), SNMP, ModbusTCP, Telnet, SSH, MQTT
1-channel watchdog
Power port assigned to Watchdog (ICMP/TCP), auto reboot starts
Power consumption measurement (kwH) with 2 energy counters: one counter counts consistently, the other counter can be reset
Measurement of current (A), voltage (V), active power (W), apparent power (VA) and reactive power (VAr)
Measurement of differential current type A (mA)
Dimensions: 120 x 65 x 53 mm
CPU QuadCore Cortex A72 (ARM v8) 64 bit SoC 1.5 GHz
RAM 4GB LPDDR4 standard (1/2/8 optional)
32GB EMMC Flash Memory
1 x Micro HDMI
2x USB 3.0, 2x COM (1xRS-232/422/485, 1xRS-232/485)
RTC: Real Time Clock
1x digital input dry (open/close)/wet (0-3V/10-30V) contact
1x digital output (120VAC @0.5A, 240VAC @0.25A, 30VDC @1A)
DC 9~32V input DC Jack or terminal input