I / O module with 7 digital inputs (DRY / WET switch) and 8 digital outputs Open Collector 30V / 30mA, RS485
RS485 I / O Module
7 digital inputs - Contact or volt in
8 digital outputs with connect contact function
Supply: 10 - 30VDC
This type of module is primarily used for industrial control, monitoring and control. Is very hardy and suitable for external applications where they can be assembled with other type of modules in order to solve a complex task. Is widely used for building automation, factory automation, production machines, energy management etc. Contact DANBIT if you have special wishes and requirements to be met.
Subcategories
There are 98 products.
RS485 I / O Module
7 digital inputs - Contact or volt in
8 digital outputs with connect contact function
Supply: 10 - 30VDC
RS485 module with digital I / O
7 digital input
8 digital output, 30volt / 30mA
RS485 interface
Baudrate 1200 ~ 115200 bps
Dual Watchdog
10 - 30 VDC, 1 W via terminal block
-25- + 75 °
DIN rail mounting
Ethernet I/O module Modbus/TCP / UDP slave
1 x RJ45 Ethernet
Redundant Power Supply
Protocol: TCP, UDP, HTTP, DHCP, BOOTP and TFTP
Web configuration and firmware update via Ethernet
2 x digital input (Wet - volts supplied)
2 x Relay, COM, NO - 250VAC 5A, 30VDC 5A
Avoid inductive load to relay contacts
With locked DI and 32-bit 3.5kHz counter
With I/O pair - input is mirrored in the other's output
Dual-watchdog with Power-on-safe value
Supply voltage: 12 - 48VDC, 1.7 Watt
Dimensions: 98 x 52 x 27 mm
Operating temperature: -25 - +75°C
8 final lecturer 250 VAC 5 A
USB type B with screw terminals
USB 2.0 Full-Speed via USB port
Plug-and-Play
PWR / RUN / ERR LED lamps
For YOUR rail mounting
Operating temperature: -25 to + 75 °
Active sub-D 25 connectors with built-in TTL I / O
Connect to USB Port
24 TTL I / O Programmable channels
Buying Relayer - Term25R8OPTI8
Relayer has 8 x optoisolated entries
The relay card has 8 x relay outputs
when purchasing input and relay cable
Recommended cable K-DB25M-F0.75
Spare part
Terminal card with 16 "Open Collector" outputs
DIN mount
for DIO Radio series
Extra digital inputs and relay outputs via RS485
3 x digital input
3 x relay output
RS485 interface
Dongle to analyze the data traffic on ZigBee. Supplied with software for analysis of collected data packets
Compact Open Board with 8 relay exits
250V / 10A Only resistive load
Controlled from USB
supply voltage: 5VDC
supply via DC Jack or terminal block
No cabinet
Compact open board with 4 relay outputs
250VAC / 30VDC / 10A resistive load only
Controlled from USB via HID (E.g. usb-relay-hid )
Supply voltage: 5VDC
Supply via DC jack or terminal block
No cabinet
Please note no software is included
Get info on USB-RELAY-HID software online.
Accessories
Protective cover
for DIO-RXX and DIO-TXX
Compact open board with 4 relay outputs
250VAC / 30VDC / 10A resistive load only
Controlled from USB via HID (E.g. usb-relay-hid )
Supply voltage: 12VDC
Supply via DC jack or terminal block
No cabinet
Please note no software is included
Get info on USB-RELAY-HID software online.
Compact open board with 1 relay output
250VAC / 30VDC / 10A resistive load only
Controlled from USB via HID (E.g. usb-relay-hid )
Supply voltage: 5VDC via USB
No cabinet
Please note no software is included
Get info on USB-RELAY-HID software online.
4 single ended input +/- 10V analog, +/- 5V, +/- 2.5V ... +/- 20mV
128kS / s for each channel sampling rate
FIFO: 4000 samples - memory 30 million data samples
24bit resolution
2 x analog output +/- 10V, +/- 5V, 0-5 / 10V
analog output 12bit resolution
Trigger mode: SW, Ext analog
1 x 32bit counter, max. 30kHz
1 x Encoder input: Qadrant / CW / CCW and pulse
3 x digital inputs (wet) up to + 30VDC
4 x digital output (Open Collector) up to + 30VDC, 100mA
Overload protection up to 1.3A
1 x Ethernet port RJ45
Security: ID, password and IP filter
Powered by the PoE or 12 - 48VDC, 2,6W
Dimensions: 120 x 76 x 38 mm | Housing: Metal, with DIN bracket
Operating temperature: -25 - + 75 ° C
8 Potential-free relay outputs - 230Vac / 16 A, 24VDC / 10 A
Relay outputs are individually via HTTPS, SNMP or Command
Startup delay from 0 to 9999 seconds. Adjusted individually
Inrush Delay is set to 1 second
Programmable on / off sequence
Activating relays can be controlled from sensor or inputs
8 channel watchdog via ICMP / TCP Ping
8 signal entrances From NO and NC units, door contacts, etc.
Entrance to sensors Temperature, humidity and air pressure
Messages via e-mail, Sylog and SNMP Trap MQTT
Depending on thresholds for sensor measurement and signal input
LED display for overall power, IP address, sensor data and error reports
Android app and iOS app
DIN bracket
Built-in web server
Web HMI
Supports Modbus TCP and MQTT protocols
2-port Ethernet switch (LAN Bypass) for Daisy-Chain Wiring
Double watchdog
Digital input: 16 channels
Wet contact input
Input high = +10 - 50VDC (ON)
Input low = < +4VDC
Supply voltage: 12 - 48VDC
Temperature: -25 - +75°C
Dimensions: 120 x 97 x 42
Industrial and IT room monitor unit
1 x RJ45 Ethernet 10/100 Mbps
USB port For USB camera
USB memory for logging, max. 64GB SD
Built-in USB hub
4 x Analog ports for sensors (can be expanded)
2 x Digital input (dry contact)
1 x CAM port (max. 10 sensors, can be expanded)
2 x Relay output
Desktop, Wall, (Option: DIN and 19" brackets as extensions)
Dimensions: 150 x 140 x 28 mm
either 128kb or 2mb buffer
DC 9v/200mA with 3mm DC plug
Baud rate from 50 to 115K
7 or 8 data bits, ODD EVEN or NONE parity