Cabinet for HMI4.3 "ETH-IC. Wall-mounted backing to 4.3" HMI panel.
Kabinet til montering inde i væggen
In this category you will find our analog and digital I / O modules. And a lot of other things including temperature sensors, Smart I / O modules, PLC and protocol converters. See blah. our 3 channel Quadrature counter with encoder for measuring eg. distance traveled.
Subcategories
There are 262 products.
Kabinet til montering inde i væggen
Double-lane recognition
Up to 60 fps at 1920 × 1080
Standalone database
IR distance up to 30 m
Day and Night function
Digital I/O (2 in / 2 out)
SD card slot for data
Built-in heater and fan
Recognize vehicles with speeds up to 100 km/h
Powered via POE / 12VDC
IP67 , Defog
31 languages on Web interface
CE, FCC, LVD, RoHS compliant
4 single ended input +/- 10V analog, +/- 5V, +/- 2.5V ... +/- 20mV
128kS / s for each channel sampling rate
FIFO: 4000 samples - memory 30 million data samples
24bit resolution
2 x analog output +/- 10V, +/- 5V, 0-5 / 10V
analog output 12bit resolution
Trigger mode: SW, Ext analog
1 x 32bit counter, max. 30kHz
1 x Encoder input: Qadrant / CW / CCW and pulse
3 x digital inputs (wet) up to + 30VDC
4 x digital output (Open Collector) up to + 30VDC, 100mA
Overload protection up to 1.3A
1 x Ethernet port RJ45
Security: ID, password and IP filter
Powered by the PoE or 12 - 48VDC, 2,6W
Dimensions: 120 x 76 x 38 mm | Housing: Metal, with DIN bracket
Operating temperature: -25 - + 75 ° C
Ethernet I/O module for the measurement of analog high-voltage differential inputs
8 x Analog input: +/-50V, +/-150V
4 x Digital output - Isolated Open Collector, max. 50VDC, 700mA per channel
16bit solution
Sample frequency: Normal mode 10 samples per second
Sample frequency fixed mode: 50 samples per second
Supports MODBUS TCP and UDP
Integrated Web Server - access with ID, password and IP filter
Power up and safe levels can be programmed
2 x RJ45 10 / 100Mbit ports - daisy-chain
Pair-connection - mirror one input to others output
Supply voltage: 12 - 48VDC 4,2Watt
Dimensions: 120 x 76 x 38 mm
Housing: plastic with DIN bracket
Ethernet Gateway for CANopen networks and Modbus RTU
1 x RJ45 10 / 100Mbps
Protocol: Modbus TCP Server
1 x RS232 / RS485 port (non-isolated)
Modbus RTU slave
Baud rate: 1200-115200
1 x CAN port
CANopen
CAN Baud rate: 10K - 1M
Built-in 120 ohm termination
Dimensions: 122 x 72 x 33 mm
Supply voltage : 10 - 30VDC, 2,5Watt
Operating temperature: -25 - + 75 ° C
DIN bracket
Module to Can 2.0a and B
ISO 11898-2 standard
Baudrate 10Kbps for 1M bps
software for setting CAN and RS232 / 422/485
Transparency between RS-232 / 485/422 Via CAN bus
Full duplex on RS-232/422 units are not supported
CAN Bus Baud Rate Configuration
CAN Accept Filter Configuration
CAN 2.0A or 2.0B Specific Choice
RS-232 / 485/422 Baud rate and data file setting
RS-232/485/422 Respond Options
Setting: Normal or pair connection
Mediekonverter fra seriel til optisk fiber
Point til Point transmission
RS232 eller RS422 eller RS485
Op til 40 km med single-mode
ST stik - duplex
Til 9/125my single mode fiber
Reducerer signalinterferens
Beskytter mod elektrisk interferens
Baud rate op til 921,6 kbps
Temperaturområde: -40 til+75°C
Forsyningsspænding: 12 - 48VDC
Mål: 100 x 90 x 22 mm
DIN beslag som tilbehør
NMT Canopen Slave
Modbus RTU Master
Error Control: Node Guarding Protocol
Node ID: Setting CAN_MRU Utility Software or LSS Protocol
PDO modes: Eventless, externally requested, cyclic and acyclic Sync
Bob Mapping: Variable
Number of SDOs: 1 Server, 0 Client
Canopen Version: DS-301 V4.02
Device Profile: DSP-401 V2.1
CIA DSP -305 V1.1
Can Baud Rate: 10K - 1M BPS
Modbus Baud Rate 1200 - 115,200 BPS
LED indicators Run, Err and Overrun
Max. 10 Modbus RTU I / O Modules
Hiring program for configuration
7-segment LED to display Node ID, Can Baud Rate and RS-485 Baud Rate
8 Potential-free relay outputs - 230Vac / 16 A, 24VDC / 10 A
Relay outputs are individually via HTTPS, SNMP or Command
Startup delay from 0 to 9999 seconds. Adjusted individually
Inrush Delay is set to 1 second
Programmable on / off sequence
Activating relays can be controlled from sensor or inputs
8 channel watchdog via ICMP / TCP Ping
8 signal entrances From NO and NC units, door contacts, etc.
Entrance to sensors Temperature, humidity and air pressure
Messages via e-mail, Sylog and SNMP Trap MQTT
Depending on thresholds for sensor measurement and signal input
LED display for overall power, IP address, sensor data and error reports
Android app and iOS app
DIN bracket
Built-in web server
Web HMI
Supports Modbus TCP and MQTT protocols
2-port Ethernet switch (LAN Bypass) for Daisy-Chain Wiring
Double watchdog
Digital input: 16 channels
Wet contact input
Input high = +10 - 50VDC (ON)
Input low = < +4VDC
Supply voltage: 12 - 48VDC
Temperature: -25 - +75°C
Dimensions: 120 x 97 x 42
Industrial and IT room monitor unit
1 x RJ45 Ethernet 10/100 Mbps
USB port For USB camera
USB memory for logging, max. 64GB SD
Built-in USB hub
4 x Analog ports for sensors (can be expanded)
2 x Digital input (dry contact)
1 x CAM port (max. 10 sensors, can be expanded)
2 x Relay output
Desktop, Wall, (Option: DIN and 19" brackets as extensions)
Dimensions: 150 x 140 x 28 mm
either 128kb or 2mb buffer
DC 9v/200mA with 3mm DC plug
Baud rate from 50 to 115K
7 or 8 data bits, ODD EVEN or NONE parity