RS485 module with 8 isolated digital inputs, with display
8 isolated digital inputs with 16 bit counter
RS485 interface
-25 ° C ~ + 75 ° C
Display
DIN rail
Screw terminal
In this category you will find our analog and digital I / O modules. And a lot of other things including temperature sensors, Smart I / O modules, PLC and protocol converters. See blah. our 3 channel Quadrature counter with encoder for measuring eg. distance traveled.
Subcategories
There are 262 products.
8 isolated digital inputs with 16 bit counter
RS485 interface
-25 ° C ~ + 75 ° C
Display
DIN rail
Screw terminal
Modbus TCP Slave Module LAN or Internet
6 x Relay, End Contact 250VAC / 5A, 30VDC / 5A
Avoid inductive load
6 x Digital input. High is 10 - 50V
supply via PoE or 12 - 48VDC
is with I / O Pair Connection - Input is mirrored to exit.
with important "Sale Setting" which sets relays as desired
watchdog which sets relays in "Safe Setting" in error detection
Dim: 123 x 72 x 35 mm
built-in your bracket
Open board til smart temperatur- eller fugt måling and styring
Password beskyttet Web baseret konfiguration og kontrol
1 x digital input med “dry contact” og “logic level” mode
1 x analog input fra 0 til 60VDC
1 relæ output med NO/NC kontakter
1-Wire input til 1 temperature eller fugtmåler
SNMP v.1 support
SNMP traps ved alarm
E-mail udsendelse ved alarm
SMTP med godkendelse (SSL/TLS er ikke supporteret)
HTTP og XML API kommandoer
Remote FTP firmware update.
18 Pin male Connector
Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
2 x RJ45 Ethernet - Daisy chain
Good communication security
Dual Watchdog
Operating temperature range: -25 ~ + 75 ° C
I/O Pair-link - input is mirrored to the other's output
8 x Relay power - electromechanical, COM NO
Relæskiftetid: on: 10ms, off: 5ms
Relay contact voltage and current: 24VDC / 250VAC / 5A
Electromechanical: Avoid inductive load
Supply voltage: 12 - 48VDC
ARM Cortex - A53 CPU , 1.2 GHz
RAM 1Gb SDRAM
16GB of memory
2 x RS232/422/485
8 x DI and 4 x relay outputs
DC input 9-32V
4G module
OS : Linux Raspbian
User need knowledge of linux and programing
Documentation for DI/O and 4G module
Network-based analog output Module
5 x Separate analogue output channels
Output signals: 0-5V, 0-10V, ± 5V, ± 10V, 4-20MA
The output signals are software configured
output signals are independently programmable and scalable
built in isolated DC-DC Supply
Voltage supply: 9 - 28VDC / 5WATT
No special software or device drivers Required
Password Protected Web setup and control pages
Static or DHCP IP address
XML and Modbus / TCP
can be updated on site
removable terminal connector
Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
Dual Watchdog
Operating temperature range: -25 ~ + 75 ° C
I/O Pair - Input Mirrors at the second's output
8 x Digital input (counter): 0 - + 50VDC (500Hz) - Wet / Dry
8 x Digital output: Open Collector 0 - + 40VDC / 650MA per Ch
2 x RJ45 Ethernet - Daisy Chain
Supply voltage: POE or 12 - 48VDC / 4Watt
Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
2 x RJ45 Daisy Chain, only data is continued Further to Dual Watchdog
Operating temperature range: - 25 ~ + 75 ° C
I / O Pair Connection - Input Mirrors to another's output
8 x Power relay - electromechanical, COM NO
Rel becoming: On: 10ms, Off: 5ms
Relay Contact voltage and current: 24VDC / 250VAC / 5A
Electromechanical: Avoid inductive load
supply voltage: POE or 12 - 48VDC
Compact open board with 4 relay outputs
250VAC / 30VDC / 10A resistive load only
Controlled from USB via HID (E.g. usb-relay-hid )
Supply voltage: 5VDC
Supply via DC jack or terminal block
No cabinet
Please note no software is included
Get info on USB-RELAY-HID software online.
Compact open board with 4 relay outputs
250VAC / 30VDC / 10A resistive load only
Controlled from USB via HID (E.g. usb-relay-hid )
Supply voltage: 12VDC
Supply via DC jack or terminal block
No cabinet
Please note no software is included
Get info on USB-RELAY-HID software online.
Compact open board with 1 relay output
250VAC / 30VDC / 10A resistive load only
Controlled from USB via HID (E.g. usb-relay-hid )
Supply voltage: 5VDC via USB
No cabinet
Please note no software is included
Get info on USB-RELAY-HID software online.
Digital temperature sensor with 1-wire interface
Sensor diameter: 5.5mm
Sensor length: 50mm
Cable: 1 meter
3-wire cable: + 5VDC, GND, data
Max distance from feel to controller is 185 meters
IP66
stainless steel sensor
16 digital inputs with isolation
Inputs with common ground GND)
Built-in 2-port Ethernet switch.
Multiple units sit on the same network cable - daisy chain
Network-based module with 16 digital inputs
built-in Web server
Web HMI
Support for both Modbus TCP and Modbus UDP protocols
Double watchdog
Wide operating temperature range: -25 ~ + 75 ° C
Built-in I / O
Digital input and counter: 16 channels
6 isolerede indgange med fælles stel og 6 relæudgange
6 x digital inputs - Wet (active at DC input)
6 x Power relay outputs - 24VDC / 250VAC / 5A (COM, NO)
protocol: Modbus TCP / UDP
1 x RJ45 Ethernet Interface
I / O Pair Function - Input Mirrors for the second exit
digital inputs with counter - max 500Hz
Minimum pulse width: 1ms
Screw terminals: 10 - 30vdc / 3Watt
Built-in Web server
Web HMI
Modbus / TCP and Modbus / UDP protocols
Good communication security
Dual Watchdog
Operating temperature range: -25 ~ + 75 ° C
I/O Pair-link - the input is mirrored in the other's output
6 x Analog inputs: 500mV +/- - +/- 10 V, 0 - 20mA (16bit)
2 x Analog outputs: 0 - +/- 10VDC, 0 - 20mA (12bit)
10 samples per second
2 x Digital input (count): Wet / Dry, max. + 30VDC (100Hz)
2 x Digital outputs: Open Collector, max. 50VDC / 700mA
2 x RJ45 Ethernet Daisy chain
Supply voltage: PoE or 10 - 30VDC / 4Watt
Auto switch relay for ignition 24 V
Incl. cable
Measures: -20 ~ + 60 ° C and 0 ~ 100% RH
Accuracy: ± 0.4 ° C; ± 3.0% RH
LCD display shows the temperature, humidity, dewpoint and
module ID
10 ~ 30 VDC power input
IP66 Waterproof
Data Logger
Memory for temperature and 4,088 humidity records
RS-485 communication interface
DCON or Modbus RTU