Temperature and moisture feel with 2.5 mm jack connector
Temperature range -40 to 120 ° C
Moisture range 0 to 99% Target 70 x 5 mm
Fits GSM-IO-PWR
Subcategories
Temperature range -40 to 120 ° C
Moisture range 0 to 99% Target 70 x 5 mm
Fits GSM-IO-PWR
12 ports PDU with individual on / off and individual and overall power meter via network
19 "1U rack mount
Integrated power measurement and monitoring per power outlet
User interface via web browser with Password
Scheduled on / off per port
Programmable sequential power up
8 x Schuko outputs, max. 10A
2 x inputs for temperature and temperature / humidity sensor with alarm
8 x Watchdog with ping off & nbsp; each connected PC
SNMP Get / Traps and Email Support
Supports Iphone and Android
Rest sale
Air conditioning management via mobile phone
Send SMS that simulates IR remote control
Fits for most air-conditioning devices
login to our website and download the manual
manual denotes Models It Supports
Control via SMS messages
Alarm at power failure
Relay output for 230VAC
Universal input for temperature sensor
Temperature sensor with 5 meter cable
Mini vertical level switch / swim switch
Assembly: Vertical
contact output: Direct load
Cable length: 30 cm
Operating temperature: -20 ° C to + 80 ° C
AC voltage Max: 130V < Br> DC voltage Max: 180V
Max current: 700mA
8 Port Networked PDU with Individual On / Off
19 "Rack Mount, 1U
User Interface via Web Browser with Password
Scheduled on / off per port
Programmable Sequential Power Up
8 x IEC C13 outputs, max. 10A - front mounted plug
2 x inputs for temperature and temperature / humidity sensor with alarm
8 x Watchdog with ping of each connected PC
SNMP Get / traps and e- mail support
Supports Iphone and Android
12 port PDU with individual on / off and assembled power meter via network
19 "rack mount, 1U
2 x power supply with 230V, 16A
User interface via web browser with Password
Scheduled on / drain per port
Programmable sequential power up
12 x IEC C13 outputs, max. 10A
2 x inputs for temperature and temperature / humidity sensor with alarm
12 x Watchdog with ping for each connected PC
SNMP Get / Traps and Email Support
Supports Iphone and Android
Multi-band 4G LTE Cat.1 controller, logger and alarm
Setup via USB, SMS and HTTP API
USB setup - use USB cable with Mini B male
2 digital "dry contacts". High on contact
2 analog inputs, 0 - 10VDC or 4-20mA input (10bit)
4 relay outputs, COM, NO and NC
1-Wire input for up to 8 Teracom sensors
1 x RS485 for max. 8 MODBUS RTU sensors
Data logger with 70,000 logs
Upload data to HTTP/HTTPS Post in XML/JSON
SMS alarm and Email alarm to 5 recipients
Push mode – XML data is sent via HTTP Post to a remote server. Responses from server may contain relay setup.
10 to 28VDC, 370mA @ 12VDC - additional PSU
Dimensions: 158 x 119 x 34 mm
Weight: 470g
Temperature: -20 - +55°C
GSM/3G/4G LTE
2 x digital input, compatible dry contact and wet contact, supports EOL connection;
2 x relay outputs (240VAC@3A)
One relay output can be switched on/off by sending an SMS text
The second relay output can be switched on for 4 minutes if inputs are activated
Supports input status recovery, external power failure alarm via SMS texts
Must be programmed with USB cable to PC
9~36VDC supply voltage and power source output for external device
Up to 3 users can receive alarm and daily report SMS
Up to 5 users can receive alarm calls;
Free SMS APP
Rechargeable backup battery and power monitoring alarm
Metal housing, IP30
Operating temperature: -10 - +70°C
Dimensions: 70 x 88 x 30 mm
Wall installation and DIN
Whip antenna with magnetic base 3m cable included
GSM / LTE alarm - 4G
Configuration via USB (Windows program) or SMS
2 x digital inputs with "dry contact" or "logic level" mode
2 x analog input from 0 to 60VDC, 10 bits
2 x relay output with NO / NC switches
1-Wire interface for 4 Teracom temperature and humidity sensors
Input can be navigated with alarm text etc.
SMS alarm - up to 5 numbers
Email alarm - up to 5 email recipients, SMTP with TLS support
1 relay can be activated with calls from up to 100 telephone numbers
Push mode - XML data is sent via HTTP Post to a remote server. Server response may include relay setup.
MQTT 3.1.1 support
Firmware update "on air"
Supply voltage: 8 - 32VDC, 2Watt - additional PSU
Dimensions: 109 x 65 x 32 mm
Weight: 152g
Temperatursensor til temperaturmåler med 2 meter kabel
Thermal sensor for mounting 3 meters
Sensor tip: stainless steel
Medium 3.0V - 5.5V supply
With new chip for each pin
BLUE pin: DATA
BLACK pin: GND
RED pin: VCC
1-wire (multiple to same pin)
Netværksbaseret enhed til tænd/sluk af 230 VAC udstyr.
Web-server indbygget - password-beskyttet
Kan pinge en stabil IP-adresse (f.eks. Google) og ved manglende svar - slukke og tænde udstyr
Remote control of the DC voltage
2 x LAN and 1 x WAN port - network switch
Power supplied from 12VDC - supplied
Output voltage 5VDC or 12VDC / 2Amp
2 x DC cables with Jack 5.5 / 2.5mm and 3.1 / 1.3mm of 1.0m
2 x CAT5E UTP network cable of 1.0m
ARM Cortex - A53 CPU , 1.2 GHz
RAM 1Gb SDRAM
16GB of memory
2 x RS232/422/485
8 x DI and 4 x relay outputs
DC input 9-32V
4G module
OS : Linux Raspbian
User need knowledge of linux and programing
Documentation for DI/O and 4G module
Intelligent 8 ports Power Distribution Unit
Justerbar sekventiel tænd / sluk
Samlet strømovervågning
Samlet spændingsindgang
Outputovervågning
Total brugt kWh
Effektfaktorgenkendelse
Driftstemperatur: Op til +55°C
8 x låsbar IEC-C13 netudtag
120 - 240VAC
Styr op til 3 PDU slaver fra en master
1 x C20 16Amp
Sensor for temperatur- og fugtighedsalarm
Alarm for vand via infrarød sensor
Røgdetektor
Automatiske alarmmeddelelser
Vandal-proof GSM dome antenna for metal roof mounting
850-960 / 1770 - 2100 MHz
with 1.5 meter RG 174 Cable
SMA male (rounder + tap)
ABS plastic - With rubber gaskets
Thread hole Ø12 mm
Track - 20 x 230 V outlet, built-in power consumption meter.
Can be cascaded with nine slaves.
Ethernet password. logo Email alert for exceeding limits and the errors
1-pole relay output - switcher L
Relay box for switching on/off 2 x 230 VAC equipment via the network
Shows current power consumption and ambient temperature on PC.
Web server built-in - password-protected.
Time schedule - time table for switching on/off
Time table for on/off. 2 x 230VAC outputs
GSM 12dBi panel antenne med 1,8 m kabel mål 23 x 9 cm
Vandal secure GSM dome dome antenna for hollow mounting
Quad band - 850/900/1800/1900 / 2170MHz
With 2.5 meters RG 174U cable - SMA he
ABS plastic - with rubber seal Ø47 x 15mm, M10 thread, 12mm
bandwidth ± 90/280 MHz
Gain 2,5dBi
vertical
Max wind speed 200km/h
Temperature gauge
1.8 Meter cable
Dallas DS18B20 Chip
Thermal sensor for mounting
Dallas DS18B20 Chip
5 Meters
Temperature sensor for mounting
10 m wire
Dallas DS18B20 Chip
With copper bracket for vertical mounting (M6, 6mm diameter mounting hole)
Measuring range: -10 to + 85 ° C Accuracy on +/- 1 ° C
Remote-controlled 230VAC power rail with on/off per output
1U 19" for rack mounting - rack bracket included
8 x 240VAC C-13 outlets
1 x C20 input plug. C-19 plug not included
Switch on / off Server via the network / Internet
User interface is via Web browser
Wi-Fi connection
Password protected
Supports iPhone and Android
measuring range -55 ° C To + 125 ° C
Fits GSM-IO-PWR
Measure 45 x 5 mm
4 ports PDU with individual power on / off and total current meter via network
1 x Alternative Type E connector (CEE 7/3) max 16A
User interface via web browser with Password
Programmable sequential power up 4 x Schuko outputs type F, max. 16A
4 x Watchdog with ping of & nbsp; each connected PC
SNMP Get / Traps and Email Support
Supporting Iphone and Android
Web-based remote control of switching on/off via the Internet
Built-in Web Server. Username + Password
MQTT, Cloud, SNMP
APP for Smartphone
Watchdog with ping of stable website (Google etc.)
4 x 230 VAC sockets - IEC C-13 output 10A and C-14 input 15A.
Web server built-in - password-protected.
VPN Client
Supports: HTTP, HTTPS/SSL, TCP/IP, PPPOE, DHCP, DDNS, SNMP v3, SMTP, NTP, TLS
Supports: Cloud Connect : AWS IOT, GOOGLE Cloud IoT, Microsoft AZURE IOT
Dimensions: 195 x 116 x 45 mm
Rack fittings are purchased separately
Power distribution device for on and off of 8 x 230vac
monitoring of total power consumption, temperature.
with slave devices Connected: Up to 128 outlets.
Network-based device for switching on/off 230 VAC equipment.
Web server built-in - password-protected
Can ping a stable IP address and if there is no response - switch equipment off and on
Timetable for switch on and off - scheduler
Additional mains cable: K-PWR-SHUKO180
Network operated relay box for switching on/off 230 VAC equipment
Shows current power consumption and ambient temperature on PC.
Web server built-in - password-protected.
With IP ping to stable website, it checks network outage.
If there is no response, it turns OFF/ON the desired external equipment.
ON/OFF can be controlled remotely from the browser.
Scheduled ON/OFF
HTTP, TCP/IP, DHCP, DDNS, SNMP v1, SMTP, NTP
GSM I / O Box. Compact access control with up to 999 users
Specified time range for access
3G / 4G 850/900/1800/1800/1900 MHz
2 digital contact inputs
1 Relay output 230vac Max. 3A
Supply voltage: 9 -15VDC
Goal: 88 x 70 x 30 mm
Operating temperature: -20 - + 60 ° C
Antenna included
App for Android and iOS
Thermal sensor for mounting incl. 10 m wire
Open board til smart temperatur- eller fugt måling and styring
Password beskyttet Web baseret konfiguration og kontrol
1 x digital input med “dry contact” og “logic level” mode
1 x analog input fra 0 til 60VDC
1 relæ output med NO/NC kontakter
1-Wire input til 1 temperature eller fugtmåler
SNMP v.1 support
SNMP traps ved alarm
E-mail udsendelse ved alarm
SMTP med godkendelse (SSL/TLS er ikke supporteret)
HTTP og XML API kommandoer
Remote FTP firmware update.
1-wire communications - several sensors can be connected to the same unit
± 3.0% relative humidity accuracy
± 0.4% relative temperature accuracy
12 bit resolution for humidity measurement
14 bit resolution for temperature measurement
Calibrated digital output
Eksellent long-term stability
Each sensor has its own unique 64-bit serial number
Device to turn on/off via the Internet.
With Wi-Fi
4 x 230 VAC sockets - IEC C-13
1 x C-14 input.
Web server built-in
Password protected.
3,6 V/1200 mAh batteri til ca. 60 timers drift ved fuld opladet
1-Wire temperature / humidity sensor
3 wires. +3.3 - 5.5VDC, Gnd, Data (yellow)
Temperature: -40 - + 80°C
Humidity: 0 - 99%RH
Temp: +/-0.5°C
Humidity: +/-3%RH
Repeatability: ±1%RH, ±0.2℃
GSM alarm controller - sends alarm SMS and calls
8 x digital inputs
Must be programmed with USB cable to PC
Microphone in, line out (listening in and conversation)
Battery back-up
Antenna with SMA male included
4G mobile network
Antenna for GPS, 2.4GHz WIFI, 4G, LTE
5MHz bandwidth
Screw mounting
4 meter cable
Temperature: -40 - +85℃
Full IP67 Waterproof
Inkl. 4 stk. temperaturføler + GPS modul
The ideal choice for Server Room and Server rack monitoring.
4 x potential-free switching relay outputs - 36VDC / 3A switches
Large LED display for power measurement, IP address, sensor data and error reports
4 x Watchdog for monitoring connected PCs (ICMP / TCP)
12 x passive signal inputs - (contact inputs) for Phoenix plugs
4 x RJ45 for temperature / humidity sensors. RS232 / 485, 1 x RJ45 for LAN
Features, limit values, alarm receivers set up on the device via supplied software
2 x 12VDC power supply inputs (redundant)
PoE - Power over Ethernet for 2111-2 the model.
Free APP for Android and iPhone
SNMP Get / Traps (SNMPv1, v2c, v3)
Rain sensor for weather station and alarms
Pulse signal When tilt container is filled with water
Making short contact between the 2 wires
Cable length: 2.8 meters
Dimensions: 150 x 60.5 x 92 mm (L x B x H)
distance between mounting holes: 135 mm
20 ports PDU with individual and total power meters via network
User interface via web browser with Password
16 x IEC C13 outputs 10A & nbsp;
1 x RJ45 to LAN and 1 x RJ45 for sensor, temperature, moisture, hPascal
4 x Schuko outputs 16A
SNMP Get / traps and email support
7 ports PDU with overall power meter through network
One power meter can be reset, the other accumulates consumption.
User interface via web browser with Password
7 x IEC C7 outputs, max. 16A (safety socket)
1 x RJ45 to LAN and 1 x RJ45 for remote sensor (temperature, humidity, hPascal
SNMP Get / traps and email support
20 ports PDU with individual and total power meters via network
Integrated residual current measurement type A
User interface via web browser with Password
16 x IEC C13 outputs 10A
1 x RJ45 to LAN and 1 x RJ45 for sensor, temperature, moisture, hPascal
4 x Schuko outputs 16A
SNMP Get / traps and email support
Energy meter Per outlet in KWh.
Cannot turn on / off exits !!
8 x 230vac IEC C13 Outlet with energy measurement in kWh per removal.
Web interface