Subcategories
-
Network products
-
Cable / Fiber / Converter / Connector
-
Keyboard / Mice / Programmable
-
Monitor / AV splitter / AV adaptor
-
Video extender, AV splitter, AV/ converter, Video Wall
-
Embedded PC / Panel-PC / Industrial PC / POS
-
Tablets / Notebooks / Accessories
-
SSD / HDD / FLASH / DVD / FDD / Media-Copy / RAID
-
Motherboard / CPU card / Accessories
-
Expansion card / ExpressCard / PCMCIA / Graphic
-
RS232 / RS422 / RS485 / LPT Parallel
-
USB converters / USB extenders / USB adapters / Firewire
-
19" Rack Cabinet / PC Cabinet / PDU / Shelf / Accessories
-
Power supplies USB / ATX / AT / Mains adapters / UPSs
-
Power Distribution / Remote monitoring / NTP-Server / Atomic clocks
-
Medical Mounts / Arms / Medical trolley
-
KVM switch / KVM extender
-
Data logning / Data collection / Measurement
-
Remote control / measuring via Ethernet and GSM
-
Industrial monitoring and control / Automation - I/O over network, USB or serial
-
Teracom Systems / Datalogning and conrol
-
DAQ / Input- / Output card / Terminal card
-
Terminal break out board
-
Electronic locks / Alarms / Access Systems
-
Video surveillance / Video camera / Recorder
-
RFID / Barcode / Magnet stribe / TAGs / POS
-
GPS tracking / Personal Tracking
-
PLC / HMI
-
Interface Force Load Cells / Instruments
-
Test Equipment / Programmer / Logic
-
ICPDAS Industrial automation
-
Korenix products
-
INSYS Industrial Automation
-
Surplus / Demo products
Active filters
EVBMR-M110, 4K2K HDMI Extender over HDBaseT med IR forlængelse (100M)
-48 VDC, 300 Watt ATX power supply, with 12V connector for P4, 2U, D2U-6300F
48V DC ATX with 12V connector for P4, 2U
These power supplies can be used where the ordinary mains voltage (230 VAC) is not available - eg. in cars or on ships.
There can be supplied three types with +12 V, +24 V or -48 VDC input.
is equipped with EMI filter.
0 dBi 2.4GHz PUK antenna, RSMA and connector
2.4GHz indoor omnidirectional antenna 0 dBi
Antenna for short range applications
1.5 meter cable, RSMA male connector
Robust, suitable for industrial machine
Gasket included - provides a watertight assembly
0 dBi 2.4GHz stub antenna, RSMA male connector
2.4GHz indoor omnidirectional antenna 0 dBi
Antenna for short-range applications
RSMA male connector for AP - (circumferential + hole)
Robust, suitable for industrial machine
1 ch 4 - 20mA power logs. Wireless to collectsor up to 150m, external term block. Bluetooth IP64. Battery operation
Wireless Temperature Logger with memory
Med Bluetooth. T&D THermo APP
Sending measurement data to Data Collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
16,000 measurements in memory with the date and time stamp
Accuracy of measurement: 0.05mA + 3% at a measuring range from 10 to 40 ° C
Removable external terminal block. Close O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Data Logger setup with Data Collector Optical
Dimensions: 62 x 47 x 19 mm
Battery type: LS14250 x 1
1 ch pulse counter data logger. Range: 0 - 27V. Wireless to collector up to 150m, Bluetooth. Cable incl. IP64. Battery operation
Wireless Pulse Logger with memory
Max. number of pulses per measurement interval: 61439 pulses
Max. Frequency: 3.5kHz (0.3ms)
Sending measurement data to Data Collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
Data Logger is not on-line
16,000 measurements in memory with the date and time stamp
Removable external terminal block. Close O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Dimensions: 62 x 47 x 19 mm
Fixed antenna: 24 mm
Battery type: LS14250 x 1
1 ch temperature logger. For Pt100/Pt1000. Wireless data collector for up to 150m, BT. ext. term block. IP64. battery operation
Wireless Temperature Logger with memory Kirke Pt1000 and Pt100 3-wire
Bluetooth T&D APP
temperature: -199 - + 600 ° C, +/- 0.3 ° C + 0.3%
Sending measurement data to the data collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
Data Logger is not on-line
16,000 readings in memory with date and time stamp
Removable external terminal block. Close O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Data Logger setup with Data Collector Optical
Dimensions: 62 x 47 x 19 mm
Battery type: LS14250 x 1
1 channel leak detector MODBUS RTU, RS485, alarm relay, Sensitivity adjustment. DIN -25 - +75°C 10 - 30VDC 1.5W
1 channel detection of fluid leakage with MODBUS
Shutter local alarm of detection of water leakage
Acoustic alarm - adjustable
RS485 2-wire MODBUS RTU
2 x LED indicators for power and alarm
Relay output for alarm for water leakage - 30VDC / 2A
Monitor cable for liquid detector
Sensor cable can be up to 500 meters
Sensitivity is adjustable
Supports DCON and Modbus RTU protocols
Embedded Dual Watchdog
Operating temperature: -25 to + 75 ° C
Small form factor with DIN bracket
Dimensions: 83 x 70 x 29 mm
Operating voltage: 10 - 30VDC
1 channel relay COM, NO, NC. 30VDC, 250VAC 10A via USB, HID
Compact open board with 1 relay output
250VAC / 30VDC / 10A resistive load only
Controlled from USB via HID (E.g. )
Supply voltage: 5VDC via USB
No cabinet
Please note no software is included
Get info on USB-RELAY-HID software online.
1 channel TCP/RTU/ASCII Modbus Gateway. RS232/RS422/RS485. TCP Server/Client, Virtual Com. 9 - 30VDC
1 channel software-selectable RS-232/485/422 port
Baud rate: 1200 - 230,400 / RS485 921,600
1 x 10/100 Mbps RJ45 Fast Ethernet port
Supports TCP Server/Client, UDP, Virtual COM and Tunneling modes
Modbus TCP/RTU/ASCII
Configuration via the web server side, the Telnet console and the Windows Utility
Upgradable firmware via Ethernet from a remote PC
Robust metal cladding; industrial EMC protection
Redundant dual DC inputs for non-stop operation
Optional DIN rail mounting
Supply: 9 - 30VDC or 5VDC / 9W
Dimensions: 78 x 65 x 28 mm
Temp: -40 - +70°C
1 channel temperature log -40 - +80°C, wireless to data collector up to 150m and BT. Internal sensor. IP67. Battery operation
Wireless Temperature Logger with memory
Bluetooth APP - T&D Thermo
Sending measurement data to Data Collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
Data Logger is not on-line
16,000 readings in memory with date and time stamp
Accuracy: +/- 0.5°C
Free Cloud service: TD WebStorage for Data collector
LCD display shows current measurements
PC software : tools and presentation included
Data Logger setup with Data collector Optical
Dimensions: 62 x 47 x 19 mm
Fixed antenna: 24 mm
Battery type: LS14250 x 1
1 channel temperature/humid logger 0 - +55°C, 10 - 95% RH. Wireless to collects up to 150m, BT. External sens. Battery operation
Wireless Temperature and Humidity Logger with memory
Bluetooth to T&D Thermo APP
Sending measurement data to Data Collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
2 x 8,000 measurements in memory with the date and time stamp
Accuracy of measurement: max. + / - 0.3 ° C, +/- 5% RH
Removable external sensor. IP64 with O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Data Logger setup with Data Collector Optical
Dimensions: 62 x 47 x 19 mm
Battery type: LS14250 x 1
1 channel transmitter 868MHz, IP66. For DIO-RXX-TRAP receiver. Battery operation 3 x AAA
1 channel transmitter to receiver with relay outputs 868MHz
1 Contact
Momentary or Pulse
Safe Communication Protocol
IP66
Supply voltage: 3 x AAA batteries
Temperature range: -10 - + 50 ° C
Measure: 176 x 68 x 25 mm
1 faset energimåler med MODBUS RTU (RS485 interface)
1 fase energimåler/logger med Windows software
1 meter DIN skinne
1 meter DIN skinne model TS-35, med en højde på 7,5mm
1 parallel port, PCI Express, high and low profile bracket included
PCI Express parallel card with 1. DB25 port
Most drivers up to Win10 available in the Download
1 Port Ethernet server, isolated. RS232 / RS422 / RS485
Clearance
serialport: RS232, RS422 or RS485
speeds from 1200 to 115 Kbps
1 Port Industrial LTE Gateway, RS232 / 422 / 485, 0-55 ° C, Moxa Oncell G3150A-LTE
1 Ports LTE Serial for Ethernet Gateway / Modem, RS232 / 422/485
GSM / GPRS / EDGE / UMTS / HSPA / LTE
Supports VPN and virtual computing
operating temperature 0- 55 ° C
IP30
12-48 VDC
DIN mounting (fittings included)
1 port industrial LTE Gateway, RS232 / 422/485, -30-70 ° C, MOXA OnCell G3150A-LTE-T
1 port LTE serial to Ethernet gateway / modem, RS232 / 422/485
GSM / GPRS / EDGE / UMTS / HSPA / LTE
Supports VPN and virtual comport
Operating temperature -30 -70 ° C
IP30
Supplied via the 12-48 VDC
DIN rail mounting (bracket supplied)
1 PORT MODBUS serial port server, RS232 / RS422 / RS485 Modbus over Ethernet. Can run Modbus TCP Master
MODBUS
Serial Device Server
1 x RS232 / 422/485 port
Atop MB5001C
WIN XP / 7/8 / WIN 10
Web Server Config.
9 ~ 30 VDC
1 port PDU with on/off and power measurement over the network. Auto-reset of equipment. Scheduled management. IEC13/14
Event and schedule controlled switching 230VAC/10A
Accurate current measurement
Input for 2 sensors - temp/humidity, pressure
RJ45 to Ethernet
NTP function
Power port on/off via HTTP(S), SNMP, ModbusTCP, Telnet, SSH, MQTT
1-channel watchdog
Power port assigned to Watchdog (ICMP/TCP), auto reboot starts
Power consumption measurement (kwH) with 2 energy counters: one counter counts consistently, the other counter can be reset
Measurement of current (A), voltage (V), active power (W), apparent power (VA) and reactive power (VAr)
Measurement of differential current type A (mA)
Dimensions: 120 x 65 x 53 mm