½ meter DIN skinne
50 cm DIN skinne model TS-35, med en højde på 7,5 mm
Subcategories
50 cm DIN skinne model TS-35, med en højde på 7,5 mm
ISM 2.4 GHz Operating Frequency
Fully Compliant with 2.4 G (IEEE802.15.4/ ZigBee Specifications)
Fully Compliant with ZigBee Pro (ZigBee 2007)
Wireless Transmission Range up to 700 m (Default)
Adjustable RF Transmission Output Power
Supports AES-128 Encryption for the Wireless Communication
GUI Configuration Software (Windows Version)
RS-232/RS-485 Interface Supported
Source Identification for the non-address Device Data Transmission
Supports Broadcast Transmission for the Redundancy Transmission Path
Supports Unicast Transmission to Reduce Network Loading
Supports Topology Utility for Network Monitoring and Improvement
DIN-Rail Mountable
ZigBee module with 6 inputs and 4 relay outputs
Dongle to analyze the data traffic on ZigBee. Supplied with software for analysis of collected data packets
Wireless network-based digital I / O module with 1-wire port
1 x Power Relay 12amp, com No, NC
1 x Digital Input Optoisolated 0 - 26VDC
1-wire bus for 4 Temp / Moisture Sensors
Wi-Fi 802.11b/g/n
Antenna inclusive
Range up to 100 meters
Logging of input, counter value
Temperature, Moisture, relay mode and volt in
Basic script for advanced flexibility
Send email alarms (up to 8 email addresses)
Static or DHCP IP address
RTC with NTP server synchronization
No software required
XML, Modbus / TCP and Remote Services
On-site updates
Removable terminal connector
Network-based analog output Module
5 x Separate analogue output channels
Output signals: 0-5V, 0-10V, ± 5V, ± 10V, 4-20MA
The output signals are software configured
output signals are independently programmable and scalable
built in isolated DC-DC Supply
Voltage supply: 9 - 28VDC / 5WATT
No special software or device drivers Required
Password Protected Web setup and control pages
Static or DHCP IP address
XML and Modbus / TCP
can be updated on site
removable terminal connector
Web-based temperature and moisture data loggs
1-wire bus for a maximum of 16 sensors (Temp / Moisture)
Permissions: Administrator, Manager, User
Tasks
50 Scheduled
50 Conditional
20 Override Schemes
Email Alarms, Custom (Encrypted Email Servers, such as Gmail)
Real Time Clock With NTP Server Synchronization
No Software Required
Basic Script Support for Advanced Flexibility
Configurable logging
Graph (logged data)
HTTPS / TLS encrypted
static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtration
On-site updates
Robust cabinet for DIN rail / wall
Supply voltage: POE or 9 - 28VDC, 134mA
Web-based temperature and moisture data loggs
1-wire bus for a maximum of 16 sensors (Temp / Moisture)
Permissions: Administrator, Manager, User
Tasks
50 Scheduled
50 Conditional
20 Override Schemes
Email Alarms, Custom (Encrypted Email Servers, such as Gmail)
Real Time Clock With NTP Server Synchronization
No Software Required
Basic Script Support for Advanced Flexibility
Configurable logging
Graph (logged data)
HTTPS / TLS encrypted
static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtration
On-site updates
Robust cabinet for DIN rail / wall
Supply voltage: 9 - 28VDC, 134MA
8 x analog inputs - Sample Rate 25 times per second
8 x input - Single ended: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
input 1 - 4 Can be 4-20mA
Web server for configuration and remote monitoring
Permissions: Administrator, Manager, User
Tasks
50 schedule planned
50 Conditional
20 overroubed
Email Alarms by Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Logging - Graph Presentation
static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: PoE or 9 - 28VDC
Ethernet-based relay module with Modbus
with I/O Pair Function
Digital signals are mirrored on another module outputs
Power Relay, 250vac, 30vdc, 5A
DINr
Supply voltage: 10 - 30vdc, 3 watts
Dim: 180 x 111 x 70 mm
Operating temperature: -25 - +75°C
Network-based I/O module control
For all ControlByWeb modules
Powerful built-in web server
Logging and automatic drawing of log files
Built-in Ethernet switch with two Ethernet connections
Expansion bus - Direct connection with up to 64 modules *
Supports USB WiFi adapters/USB flash
For 1-wire bus for temp/humidity sensors
Custom email alerts
Logical scripts or programs with Lua
Advanced planning in full calendar
Protocols: HTTP, HTTPS, SSL, SMTP, Modbus/TCP
Remote Services ™ server and client etc
Email alerts based on user defined conditions
Static or DHCP IP address configuration
XML, Modbus/TCP and SNMP interface options
Expansion bus - up to 32 I/O modules or remote modules up to 100 I/O
Peer-to-Peer communication (P2P)
1-wire bus: Up to 16 sensors for temp / moisture : -55°C - +125°C
Web server for configuration and remote monitoring
Permissions: Administrator, Manager, User
Task Builder:
50 Scheduled Tasks
50 Conditional Tasks
20 Restart tasks
20 Override Schemes
Email Alarms by User Terms
RTC with NTP synchronization
configuration of almost all I/O
No software Required
Basic Script Support for Advanced flexibility
Data logging, graphs (logged data)
Static or DHCP IP address
Modbus, SNMP, Remote Service, IP Filtering
6 isolerede indgange med fælles stel og 6 relæudgange
16 digital inputs with isolation
Inputs with common ground GND)
Built-in 2-port Ethernet switch.
Multiple units sit on the same network cable - daisy chain
Network-based module with 16 digital inputs
built-in Web server
Web HMI
Support for both Modbus TCP and Modbus UDP protocols
Double watchdog
Wide operating temperature range: -25 ~ + 75 ° C
Built-in I / O
Digital input and counter: 16 channels
10 pcs. Independent high voltage 15A relays - SPDT (Form C)
Relay spade terminals. COM, NO, NC
Web Server for Browser-based setup and control
No software or device drivers required
XML status and control page make PC applications simple
Can function as a Modbus/TCP slave
On / Off and Pulses
DIN rail Mountable - Open Board
LED Indicates the current relay mode
Ideal for industrisal applications
Power supply: 9 - 28 VDC / 1.5A
UL Approved relays (E197852).
Network-based Digital I/O Module
2 x Power Relay 3 Amp, COM NO, NC
2 x Digital Input Optoisolated 0 - 26VDC
Memory for 50,000 Loggings
Logging of Input, Counter value
Relay state and Volt in
Basic script for advanced flexibility
Send email alarms (up to 8 email addresses)
Static or DHCP IP address
RTC with NTP server synchronization
No software required
XML, Modbus / TCP and Remote Services
On-site updates
Removable terminal connector
Supply voltage: POE or 9 - 28VDC
Controlbyweb I / O module with digital in and relay Out
No programming required
Full control of web browser or XML messages
is also a Modbus / TCP slave
password protected
30vdc , 240vac, 12a relay switch
on / off or pulsed relay states
optically isolated digital input
suitable for monitoring / relation management
Remove-Reloading (peer-to-peer)
Auto-restart
Selectable TCP ports
Removable terminal connector
DIN rail or wall mounting
Power supply: 9-28VDC / 0.5a
Controlbyweb I / O module with digital in and relay Out
No programming required
Full control of web browser or XML messages
is also a Modbus / TCP slave
password protected
30vdc , 240vac, 12a relay switch
on / off or pulsed relay states
optically isolated digital input
suitable for monitoring / relation management
Remove-Reloading (peer-to-peer)
Auto-restart
Selectable TCP ports
Removable terminal connector
DIN rail or wall mounting
Power supply: 9-28VDC / 0.5a
Network-based Digital I/O Module
2 x Power Relay 3 Amp, COM NO, NC
2 x Digital Input Optoisolated 0 - 26VDC
Memory for 50,000 Loggings
Logging of Input, Counter value
Relay state and Volt in
Basic script for advanced flexibility
Send email alarms (up to 8 email addresses)
Static or DHCP IP address
RTC with NTP server synchronization
No software required
XML, Modbus / TCP and Remote Services
On-site updates
Removable terminal connector
Supply voltage: 9 - 28VDC
Web based controller with 8 digital inputs
Digital High is: +4 - +26VDC
8 x digital inputs Opto-isolated
Common ground
200Hz Counter - 24bit
Tasks: 50 Schedule Planned, 50 Conditional, 20 Tuffer Terms
Email Alarms by defined conditions
Supports encrypted e-mail servers such as Gmail
RTC with NTP server synchronization
No software required
Graph (Logged data)
HTTPS / TLS encrypted
Static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Dim: 98 x 78 x 36 mm
Web based controller with 8 digital inputs
Digital High is: +4 - +26VDC
8 x digital inputs Opto-isolated
Common ground
200Hz Counter - 24bit
Tasks: 50 Schedule Planned, 50 Conditional, 20 Tuffer Terms
Email Alarms by defined conditions
Supports encrypted e-mail servers such as Gmail
RTC with NTP server synchronization
No software required
Graph (Logged data)
HTTPS / TLS encrypted
Static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Dim: 98 x 78 x 36 mm
Expansion module for X-400, X-600 Controller
with Daisy Chain for several I/O modules
16 x Dry Spst Form c relay - Signal relay
Relays can be grouped in common
Activation of Relays Can switch individual
16 x digital input - optoisolated, 4 - 28VDC
4 x analog inputs - 12bit, 0 - 5VDC, common gnd
LED Indication - Relay and DI status
Supply voltage: 9 - 28VDC ( Preferably 24VDC)
Dim: 219 x 126 x 50 mm
Weight: 342g
DIN mount
WEB-based data logger for temperature and humidity sensors
Can be programmed to 3 second sampling time
-55 - + 125°C, -40 - + 80°C 0 - 100%rH
4 pcs. 1-Wire bus for 16 sensors, each
Max. 64 pcs. temperature or temperature/humidity sensors
Max. distance to sensors: 180 meters
Tasks: 50 scheduled, 50 Conditional, 20 override
Email alerts, custom (encrypted email servers, such as gmail)
Real-time clock with NTP server synchronization
No software required
Configurable logging
Graph (logged data)
HTTPS/TLS encrypted
Static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtering
On-site is updated
For DIN rail / wall
Supply voltage: PoE or 9 - 28VDC, 134mA
Dimensions: 98 x 78 x 36 mm
WEB-based data logger for temperature and humidity sensors
Can be programmed to 3 second sample time
-55 - + 125°C, -40 - + 80°C 0 - 100%rH
4 pcs. 1-Wire bus for 16 sensors, each
Max. 64 pcs. temperature or temperature/humidity sensors
Max. distance to sensors: 180 meters
Tasks: 50 scheduled, 50 Conditional, 20 override
Email alerts, custom (encrypted email servers, such as gmail)
Real-time clock with NTP server synchronization
No software required
Configurable logging
Graph (logged data)
HTTPS/TLS encrypted
Static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtering
On-site is updated
For DIN rail / wall
Supply voltage: 9 - 28VDC, 134mA
Dimensions: 98 x 78 x 36 mm
Web based controller with I/O, 1-wire bus
4 x digital inputs (Common GND)
1-wire bus, max. 16 sensors (temp / moisture etc.)
Permissions: Administrator, Manager, User
Tasks
50 Scheduled
50 Conditional
16 Automatic Restart
20 Over Rule Terms
E-mail Alarms by defined conditions
Supports encrypted e- Mail servers such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Configurable Logging
Graph (Logged Data)
HTTPS / TLS encrypted
Static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Web based controller with I/O, 1-wire bus
4 x digital inputs (Common GND)
1-wire bus, max. 16 sensors (temp / moisture etc.)
Permissions: Administrator, Manager, User
Tasks
50 Scheduled
50 Conditional
16 Automatic Restart
20 Over Rule Terms
E-mail Alarms by defined conditions
Supports encrypted e- Mail servers such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Configurable Logging
Graph (Logged Data)
HTTPS / TLS encrypted
Static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: PoE or 9 - 28VDC
4 x analog inputs with common GND
input voltage: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
Input current: 4-20mA - 200 Ohm Shunt resistance
2 X digital inputs / outputs: 0 - 5VDC
Digital I/O and Counter set up via the web server
1-wire bus for a maximum of 16 sensors
Temp/moisture/ultrasound, etc.
ermissions: Administrator, Manager , User
Tasks
50 Schedule Scheduled
50 Conditional
20 Torrect Scheduled
Email Alarms Based on Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
Basic script support for advanced flexibility
Logging and graph view
static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
4 x analog inputs with common GND
input voltage: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
Input current: 4-20mA - 200 Ohm Shunt resistance
2 X digital inputs / outputs: 0 - 5VDC
Digital I/O and Counter set up via the web server
1-wire bus for a maximum of 16 sensors
Temp/moisture/ultrasound, etc.
ermissions: Administrator, Manager , User
Tasks
50 Schedule Scheduled
50 Conditional
20 Torrect Scheduled
Email Alarms Based on Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
Basic script support for advanced flexibility
Logging and graph view
static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
Modbus Master Controller for max. 32 Modbus RTU devices
1-wire bus for a maximum of 16 sensors (temp / moisture etc.)
Tasks:
50 schedule planned, 50 conditional
20 Terrul Terms
Email Alarms by defined conditions
Supports encrypted email servers, such as Gmail
RTC with NTP server synchronization
No software required
Configurable logging
Graph (logged data)
HTTPS / TLS encrypted
static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Robust cabinet for DIN rail / wall
Supply voltage: 9 - 28VDC
8 x analog inputs - Sample Rate 25 times per second
8 x input - Single ended: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
input 1 - 4 Can be 4-20mA
Web server for configuration and remote monitoring
Permissions: Administrator, Manager, User
Tasks
50 schedule planned
50 Conditional
20 overroubed
Email Alarms by Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Logging - Graph Presentation
static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Digital temperature sensor with 1-wire interface
Sensor diameter: 5.5mm
Sensor length: 50mm
Cable: 1 meter
3-wire cable: + 5VDC, GND, data
Max distance from feel to controller is 185 meters
IP66
stainless steel sensor
Water detector with normally closed relay output
Supply voltage: 5VDC / 10mA
Relay contact: max. 30VDC/500mA
Red: +5VDC
Black: GND
Green: Relay contact
White: Relay contact
REMEMBER: Relay contact opens when water is removed.
Spare part
Accessories for MFI-Mport. PIR sensor for ceiling mounting
ZigBee modul med 14 indgange
ZigBee modul med 8 indgange
Master, med Ethernet port og 1Kb buffer
Slavemodul med Ethernet til ZIG-MST-E-I
1-wire adapter box for K Thermopler element
acquire K-thermocoupler sensor
adapter with built-in DS18B20 Chip
interface is + 5VDC, GND, data
screw terminal for K-Thermoføler
Spare part
Terminal card with 16 "Open Collector" outputs
DIN mount
for DIO Radio series
Measures: -20 ~ + 60 ° C and 0 ~ 100% RH
Accuracy: ± 0.4 ° C; ± 3.0% RH
LCD display shows the temperature, humidity, dewpoint and
module ID
10 ~ 30 VDC power input
IP66 Waterproof
Data Logger
Memory for temperature and 4,088 humidity records
RS-485 communication interface
DCON or Modbus RTU
Double-lane recognition
Up to 60 fps at 1920 × 1080
Standalone database
IR distance up to 30 m
Day and Night function
Digital I/O (2 in / 2 out)
SD card slot for data
Built-in heater and fan
Recognize vehicles with speeds up to 100 km/h
Powered via POE / 12VDC
IP67 , Defog
31 languages on Web interface
CE, FCC, LVD, RoHS compliant
280 VAC 20 A solid state relay
Flange-mounting
ONLY for AC voltage
280 VAC 120 A solid state relæ til panelmontering
1-axis vibration measurement
Frequency range: 10 Hz to 1K Hz
Amplitude range: ±8g
Data Format:
Acceleration(mg): RMS, Maximum, P-P
Velocity(mm/s): RMS
Top 10 spectrum values(Amplitude/Frequency)
Crest Factor
Supported Modbus RTU Slave protocol
Size: 51 x 30 x 19mm
Supply voltage: 10 - 30VDC
Temp: -25 - +75°C
either 128kb or 2mb buffer
DC 9v/200mA with 3mm DC plug
Baud rate from 50 to 115K
7 or 8 data bits, ODD EVEN or NONE parity
18 Pin male Connector
Single-Mode Fiber (Multi-Mode optional)
1-Channel Duplex Rs485
Point-to-Point or Daisy-Chain (M485-FIBER-SR is needed)
DC input 5V (< 3W)
Operating tempeture: -45 C~+75 C
Up to to 115.2Kbps data rate
Single-Mode Fiber (Multi-Mode optional)
1-Channel Duplex Rs485
Point-to-Point or Daisy-Chain (M485-FIBER-ST is needed)
DC input 5V (< 3W)
Operating tempeture: -45 C~+75 C
Up to to 115.2Kbps data rate