Sæt udstyr med RS232, RS422 og RS485 interface på et Profibus system.
3,162.00 kr
Item number M485-PROFI-I
DANBIT has a wide range of products. Below you will find a lot of our main categories with categories below them. Since DANBIT's founding in 1970, our product range has expanded significantly. From focusing solely on electronic measurement, we currently have over 8,000 different products. This means that we can better meet your needs. If the task is to be tailored, we can, in cooperation with our close suppliers, find out exactly the product you need to solve your task.
Sæt udstyr med RS232, RS422 og RS485 interface på et Profibus system.
80188, 40 MHz CPU
Built-in Rome-DOS and Rome Disc Various Storage Media
512 KB Flash
2 KB EEPROM
Various communication interfaces
RS232 - Number is model dependent
1 x. RS485
Programmable LED Indicator
Built-in WatchDog Timer
RS485 Module with 16 digital outputs
16 x digital outputs, Open Collector
Output load: 30VDC / 100mA per Port
Common gnd
voltage: 10 - 30vdc
Your bracket
Point-to-Point Fiber converter RS232 / RS422 / RS485
Multi Mode 62.5/125 or 50//125my, wavelength 850nm
Power is supplied from 10 - 30VDC / 2 Watt
DIN rail bracket.
Up to 2km
ST connector
RS485 I / O Module
7 digital inputs - Contact or volt in
8 digital outputs with connect contact function
Supply: 10 - 30VDC
8 digital outputs and 4 digital inputs
Open Collector Output
Photocouple Isolation
Digital input channels can be used as 16-bit counters
Configurable Power-on Value settings
Configurable settings for sure value
3750 Vrms insulation voltage
Dual Watchdog
Wide operating temperature range: -25 to + 75 ° C
8 digital contact inputs
8 digital outputs "Open source" from joint terminal
RS485 interface
DIN bracket
screw terminal
RS485 Module - Slave, with digital input
8 x digital inputs for DC and AC
Voltage monitoring
input voltage: 80 - 250VAC / DC
Supply: 10 -30vdc
RS485 Module with 16 digital inputs
inputs are Dry Contact - High at contact to GND
RS485 The module is slave
supply: 10 - 30vdc
DIN bracket
RS485 Slave module with 8 digital inputs
6 pcs. Balanced
2 pcs. With joint GND.
Sink and Source Inputs
16 Bit Counter
RS485 Bus
Supply voltage: 10 - 30VDC
Dim: 123 x 72 x 35 mm
RS485 module with 4 analog outputs
0-20mA or 0 - +/- 10V
D / A response time: 10ms
Resolution: 14bit
Supply voltage: 10 - 30vdc
Power or Voltage Output
0 - +10VDC, 0 - 20mA, 4 - 20mA
Resolution: 12-bit
Software Selectable Power or Voltage Output
Output Cable Detector for Power Output (4 - 20mA)
Backlink Voltage or Current
Configurable Power-on Value
Configurable Safe Value
3000 VDC Intra Module Isolation
Programmable Output Slope
Dual Watchdog
Temperature Range: -25 to +75°C
Optoisolated RS232 for RS422 / 485 Converter
3000vdc isolation
Up to 1.2 km on the RS422 / RS485
1.2kbit/s to 115.2 kbit/s, automatic baud rate
DB9 female connector for RS232 Signal
Screw terminals for RS422 / 485 signals
Supply 10 to 30 VDC
RS485 for RS232 or RS422 for RS232
optoisulated RS232 for RS422 / 485 Converter
supply voltage is isolated against RS232 page
Supply voltage is isolated against RS485 / 422 page
Automatic Baud rate control
RS232 galvanic isolator, 3000VAC
With dual DC-DC converter, provides isolation both ways
Transmits Tx, Rx, RTS and CTS or DSR and DTR (selected)
Up to 115 kbit / s
Entrance: DB9 female, output: DB9 male
10-30VDC, screw terminal
DIN rail
Optoisolerede RS232 til RS422/485 konverter
3000Vdc isolation
24Vdc, 1.2W
RS-232 (DB9)
RS485 (2-Wire) eller RS422 (4-Wire)
Speed (bps): 1.200, 2.400, 4.800, 9.600,
19.2 k, 38.4 k, 57.6 k, 115.2 k
RTS control and RS-422 (switchable)
Module for PT100 or PT1000 sensor with 4-, 3- or 2-wire
for nickel temperature sensor (Ni RTD)
16 bit resolution
15 Measurements per second (Total)
Supply voltage: 10 - 30vdc / 1 Watt
Master RS485 must establish bias voltage
Dim: 123 x 72 x 35 mm
RS485 Module for temperature sensors
1 x input for 2-, 3- or 4-wire PT100,Pt1000 sensor
Nickel Temperature sensor
Supply voltage: 10 - 30vdc
8 channel analog input module for RS485 Bus
16bit resolution
10 measurements per second (total)
for current measurement - shunt with 125 ohm resistance
Supply voltage: 10 - 30vdc / 1.3 watt
Dim: 123 x 72 x 35 mm
with your bracket
RS485 Module for measuring voltage and power
is with 15VDC transmitter output for power loop
1 x analog input 0-20MA, 0 - +/- 10V
1 x digital input. High is closed Contact
2 x Digital output (Open Collector) + 50VDC / 30mA
Supply voltage: 10 - 30VDC
Dim: 123 x 72 x 35 mm
RS485 Module for load cells
2 analog inputs for 4 wire load cell,
1 excitation Exit
1 Digital input
4 digital outputs
Supply: 10 - 30VDC
20 channel analog input module for RS485 Bus
16bit resolution
20 Single Ended inputs (common frame) - Only for Volt
10 differential entrances for volts about power
10 measurements per second (Total )
Jumper Setting in the module
Supply voltage: 10 - 30vdc / 1.3 watts
Dim: 123 x 72 x 35 mm
DIN bracket
1 A/D indgang til vejecelle,
1 D/A udgang
4 digitale udgange
Base unit with display and optical communication
Jig for programming T&D data loggers
Jig for collecting stored log data from T&D data loggers
USB connection to PC
Free software for PC
Battery operation - Operating time approx. 100 days
OPTIONAL: AC adapter is acquired 6VDC, 3.5 / 1.5 mm plug
Dim: 125 x 58 x 26 mm
Weight: 90 g
Dataopsamler med display og USB
Kun til T&D BLÅ SERIE Dataloggere
Wireless data logger for humidity, temperature and CO2 measurement
Additional purchase Data collector for retrieving measurement data.
Data collector can be connected to T&D Cloud or PC
Operating time on battery alone is 2 days.
Additional power supply: LOG-DC5V
Wireless transfer of data to Data Collector
Impulse and voltage logger with cable shoe cable
cannot be included in TD white series
Wireless Temperature Logger with memory
Bluetooth T&D APP
For Pt100 and Pt1000 3-wire
Temperature: -199 - + 600°C, +/-0.3°C + 0.3%
Sends measurement data to Data Collector (Base Station) on 870MHz
Distance between Datalogger and Data Collector up to 150 meters
Battery operation up to 10 months with one upload per day
Data loggers are not on-line
16,000 measurements in memory with date and time stamp
Removable external terminal block. Close with O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Data logger setup with Data Collector Optical
Dimensions: 62 x 47 x 19 mm
Fixed antenna: 24 mm
Battery type: LS14250 x 1
Wireless Temperature Logger with memory
Med Bluetooth. T&D THermo APP
Sending measurement data to Data Collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
16,000 measurements in memory with the date and time stamp
Accuracy of measurement: 0.05mA + 3% at a measuring range from 10 to 40 ° C
Removable external terminal block. Close O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Data Logger setup with Data Collector Optical
Dimensions: 62 x 47 x 19 mm
Battery type: LS14250 x 1
Wireless Pulse Logger with memory
Max. number of pulses per measurement interval: 61439 pulses
Max. Frequency: 3.5kHz (0.3ms)
Sending measurement data to Data Collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
Data Logger is not on-line
16,000 measurements in memory with the date and time stamp
Removable external terminal block. Close O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Dimensions: 62 x 47 x 19 mm
Fixed antenna: 24 mm
Battery type: LS14250 x 1
Wireless Temperature Logger with memory
Bluetooth APP: T&D Thermo
Sending measurement data to Data Collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
Data Logger is not on-line
16,000 measurements in memory with the date and time stamp
Accuracy of measurement: max. + / - 0.5 ° C range depending
Removable external sensor. Close O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Data Logger setup with Data Collector Optical
Dimensions: 62 x 47 x 19 mm
Battery type: LS14250 x 1
Wireless Temperature and Humidity Logger with memory
Bluetooth to T&D Thermo APP
Sending measurement data to Data Collector (Base Station) at 870MHz
Distance between Data Logger and Data collector up to 150 meters
Battery operation up to 10 months at an upload per day
2 x 8,000 measurements in memory with the date and time stamp
Accuracy of measurement: max. + / - 0.3 ° C, +/- 5% RH
Removable external sensor. IP64 with O-ring
Free Cloud service: TD WebStorage for Data Collector
LCD display shows current measurements
PC software: tools and presentation included
Data Logger setup with Data Collector Optical
Dimensions: 62 x 47 x 19 mm
Battery type: LS14250 x 1
Radio base station retrieves Log data from loggers
base station is a link between loggers and PC
base station data from 100 wireless loggers
Frequency Band Base Station and Data Logger is 870MHz
Up to 150meter - depending on conditions
Greater distance with repeaters (radio-relay stations)
Transfers the log data via GSM 3G GPRS mobile network
USB interface to PC for setup:
base station, connection dock for data Like (Optical )
Protocol: SMTP (POP before SMTP AUTH (login) FTP, SMS
SMTPS (SMTP over SSL)
Temperature: -10 - + 55 ° C
Dimensions: 96 x 66 x 39 mm | Power supplied
only for T&D loggers
Radio base station retrieves Log data from loggers
base station is a link between loggers and PC
base station data from 100 wireless loggers
Frequency Band Base Station and Data Logger is 870MHz
Up to 150meter - depending on conditions
Greater distance with repeaters (radio-relay stations)
interface for presentation PC is Wifi
USB interface to PC for setup:
base station, connection dock for Data Like (Optical)
Protocol: SMTP (POP before SMTP-AUTH (login) FTP, SNTP, DHCP, DNS)
temperature: -10 - + 60 ° C
Dimensions: 102 x 83 x 28 mm
Power supply included
Only for T&D loggers
Data collector with LCD display
USB interface for PC
optical communication for units of measurement
Short Range radio communication for units of measurement
Only for TD data loggers
Data collector for wireless data loggers
Repeater - Radio relay station provides greater range
Radio distance to Dataloggers is approx. 150 meters
Radio frequency is 870MHz
Battery operation as repeater (Radio relay station) for 6 months.
Automatic repeater function
Wireless Data Collector from Dataloggers.
Data is transferred to PC via USB
Bluetooth
Has docking holder for setting up Datalogger functions
Operating temperature: -10 - +60°C
Dimensions: 96 x 65 x 25 mm
Weight: 70g
Only for T&D Dataloggers
4 channel data logger with display
External memory with SD slot
USB port for PC
input: DC to 100Hz
+/- 0.3 Volt to +/- 24 volts
2ms Log -Interval with 10 Microvolt resolution
Log intervals: 2 MS to 60 minutes
Number of log intervals: 23
Daisy-Chain 4 x Log-MCR4V
Battery operation: 4 days to 130 days, dependent on logging
External power supply: Micro-USB adapter (not incl.)
Residual sale
2 channel temperature logger with external sensor
Temperature sensor: -40 - + 140 ° C
Freedding temperature: -40 - + 80 ° C
1 x RJ45 Ethernet
1 x Power Jack 3.5 / 1.5 mm 6VDC
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I / O module, counter, timer, email
Modbus / TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet to 6 x Analog input: 0 - +/- 10V, 0 - 20mA
A / L solution: 16bit
2 x Analog output: 0 - +/- 10V, 0 - 20mA
A / O resolution: 12bit
2 x Digital outputs: 0 - + 50VDC / 700mA Open Collector
2 x Digital input: Dry / Wet: 0 - + 30VDC < br> D / I count: 16bit, 50Hz
Power supply: PoE or 12 - 48VDC / 4.5Watt
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I / O module, counter, timer, email
Modbus / TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet
16 x Digital input: Wet: 0 - + 50VDC
D / I count: 16bit, 50Hz
Power supply: PoE or 12 - 48VDC / 4.5 Watt
Adapter, multi mode, LC-LC, 62.5/125my
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I / O module, counter, timer, email
Modbus / TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet
7 x Temperature sensor inputs (differential)
2/3-wire Pt100, Pt1000, Ni120, CU100, Cu1000
A/I resolution: 16bit
12 samples per second (Total)
Individual sensor configuration
Power supply: PoE or 12 - 48VDC / 4.5Watt
1 x RJ45 - 10/100 Base-TX Ethernet
Can be powered from a PoE
Integrated Web Server Setup
Logical functions with IF-THEN-ELSE
Rules, I / O, CGI counter, Timer, etc.
Email setup via Web browser
Modbus / TCP Protocol to 6 x Digital input (Wet Contact - external voltage for High)
Digital input has 16 bits counter
6 x Relay Power Output: 5A at 30VDC / 250VAC
Power over Ethernet (PoE) or an external DC power supply
Supply voltage: PoE or 12 - 48VDC / 5Watt
temperature range -25 ° C ~ + 75 DEG C
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I/O module, counter, timer, email
Modbus/TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet
8 x Power relay output, COM NO
Relay switch: 30VDC, 250VAC 5A, only resistive load
Supply voltage: PoE or 12 - 48VDC / 5.5Watt
Intelligent Controller with Web Server
Logical functions, such as: IF-THEN-ELSE
No programming. Just select, click and finish
Supporter: I/O module, counter, hour, e-mail
Modbus / TCP protocol for SCADA software Seamless integration
IEEE 802.3af compatible power over Ethernet ( Poe)
1 x RJ45 - 100Mbit Ethernet
7 x Analog input: 0 - +/-2.5V, 0 - 20mA (ext. Resistors)
A/I Resolution: 16bit
10 Samples per Second
A/I Also to Thermocouller: J, K, T, E, R, S, B, B, C, L, M, LDIN43710
6 x Digital Output: 0 - + 50VDC / 700mA Open Collector
Supply voltage: POE or 12 - 48VDC / 4.5Watt
8 digitale isolerede ind- og udgange Udvidelsesmoduler til L-CON-LOG serien
Suitable for the service technician
For Servers, embedded PCs that are not connected to KVM
A laptop will now be screen, keyboard and mouse.
Box has input for VGA
Box has USB output for emulation of keyboard and mouse.
8 digitale ind- og udgange Udvidelsesmoduler til L-CON-LOG serien
Built-in Web server
Logical functions with IF-THEN-ELSE setting
IF-THEN-ELSE for simple set of conditions
No more programming. Just click and finished
Supports I / O, counter, timer, calendar, e-mail, rules
Data Logger and data files supported rewind feature
Modbus TCP / RTU protocol for SCADA software seamless integration
I/O-Board XW with inputs and outputs
Supports I-7000 Remote I / O modules (up to 16)
Supports Modbus RTU slave units (up to 10)
SNTP time synchronization supported
Support SMS (GSM: Quad-band 850/900/1800/1900 MHz)
Supply voltage: 12 - 48VDC
Measures: -20 ~ + 60 ° C and 0 ~ 100% RH
Accuracy: ± 0.4 ° C; ± 3.0% RH
LCD display shows the temperature, humidity, dewpoint and
module ID
10 ~ 30 VDC power input
IP66 Waterproof
Data Logger
Memory for temperature and 4,088 humidity records
RS-485 communication interface
DCON or Modbus RTU