½ meter DIN skinne
50 cm DIN skinne model TS-35, med en højde på 7,5 mm
Subcategories
50 cm DIN skinne model TS-35, med en højde på 7,5 mm
ISM 2.4 GHz Operating Frequency
Fully Compliant with 2.4 G (IEEE802.15.4/ ZigBee Specifications)
Fully Compliant with ZigBee Pro (ZigBee 2007)
Wireless Transmission Range up to 700 m (Default)
Adjustable RF Transmission Output Power
Supports AES-128 Encryption for the Wireless Communication
GUI Configuration Software (Windows Version)
RS-232/RS-485 Interface Supported
Source Identification for the non-address Device Data Transmission
Supports Broadcast Transmission for the Redundancy Transmission Path
Supports Unicast Transmission to Reduce Network Loading
Supports Topology Utility for Network Monitoring and Improvement
DIN-Rail Mountable
ZigBee module with 6 inputs and 4 relay outputs
Dongle to analyze the data traffic on ZigBee. Supplied with software for analysis of collected data packets
Wireless network-based digital I / O module with 1-wire port
1 x Power Relay 12amp, com No, NC
1 x Digital Input Optoisolated 0 - 26VDC
1-wire bus for 4 Temp / Moisture Sensors
Wi-Fi 802.11b/g/n
Antenna inclusive
Range up to 100 meters
Logging of input, counter value
Temperature, Moisture, relay mode and volt in
Basic script for advanced flexibility
Send email alarms (up to 8 email addresses)
Static or DHCP IP address
RTC with NTP server synchronization
No software required
XML, Modbus / TCP and Remote Services
On-site updates
Removable terminal connector
Network-based analog output Module
5 x Separate analogue output channels
Output signals: 0-5V, 0-10V, ± 5V, ± 10V, 4-20MA
The output signals are software configured
output signals are independently programmable and scalable
built in isolated DC-DC Supply
Voltage supply: 9 - 28VDC / 5WATT
No special software or device drivers Required
Password Protected Web setup and control pages
Static or DHCP IP address
XML and Modbus / TCP
can be updated on site
removable terminal connector
Web-based temperature and moisture data loggs
1-wire bus for a maximum of 16 sensors (Temp / Moisture)
Permissions: Administrator, Manager, User
Tasks
50 Scheduled
50 Conditional
20 Override Schemes
Email Alarms, Custom (Encrypted Email Servers, such as Gmail)
Real Time Clock With NTP Server Synchronization
No Software Required
Basic Script Support for Advanced Flexibility
Configurable logging
Graph (logged data)
HTTPS / TLS encrypted
static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtration
On-site updates
Robust cabinet for DIN rail / wall
Supply voltage: POE or 9 - 28VDC, 134mA
Web-based temperature and moisture data loggs
1-wire bus for a maximum of 16 sensors (Temp / Moisture)
Permissions: Administrator, Manager, User
Tasks
50 Scheduled
50 Conditional
20 Override Schemes
Email Alarms, Custom (Encrypted Email Servers, such as Gmail)
Real Time Clock With NTP Server Synchronization
No Software Required
Basic Script Support for Advanced Flexibility
Configurable logging
Graph (logged data)
HTTPS / TLS encrypted
static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtration
On-site updates
Robust cabinet for DIN rail / wall
Supply voltage: 9 - 28VDC, 134MA
8 x analog inputs - Sample Rate 25 times per second
8 x input - Single ended: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
input 1 - 4 Can be 4-20mA
Web server for configuration and remote monitoring
Permissions: Administrator, Manager, User
Tasks
50 schedule planned
50 Conditional
20 overroubed
Email Alarms by Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Logging - Graph Presentation
static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: PoE or 9 - 28VDC
Ethernet-based relay module with Modbus
with I/O Pair Function
Digital signals are mirrored on another module outputs
Power Relay, 250vac, 30vdc, 5A
DINr
Supply voltage: 10 - 30vdc, 3 watts
Dim: 180 x 111 x 70 mm
Operating temperature: -25 - +75°C
Network-based I/O module control
For all ControlByWeb modules
Powerful built-in web server
Logging and automatic drawing of log files
Built-in Ethernet switch with two Ethernet connections
Expansion bus - Direct connection with up to 64 modules *
Supports USB WiFi adapters/USB flash
For 1-wire bus for temp/humidity sensors
Custom email alerts
Logical scripts or programs with Lua
Advanced planning in full calendar
Protocols: HTTP, HTTPS, SSL, SMTP, Modbus/TCP
Remote Services ™ server and client etc
Email alerts based on user defined conditions
Static or DHCP IP address configuration
XML, Modbus/TCP and SNMP interface options
Expansion bus - up to 32 I/O modules or remote modules up to 100 I/O
Peer-to-Peer communication (P2P)
1-wire bus: Up to 16 sensors for temp / moisture : -55°C - +125°C
Web server for configuration and remote monitoring
Permissions: Administrator, Manager, User
Task Builder:
50 Scheduled Tasks
50 Conditional Tasks
20 Restart tasks
20 Override Schemes
Email Alarms by User Terms
RTC with NTP synchronization
configuration of almost all I/O
No software Required
Basic Script Support for Advanced flexibility
Data logging, graphs (logged data)
Static or DHCP IP address
Modbus, SNMP, Remote Service, IP Filtering
6 isolerede indgange med fælles stel og 6 relæudgange
16 digital inputs with isolation
Inputs with common ground GND)
Built-in 2-port Ethernet switch.
Multiple units sit on the same network cable - daisy chain
Network-based module with 16 digital inputs
built-in Web server
Web HMI
Support for both Modbus TCP and Modbus UDP protocols
Double watchdog
Wide operating temperature range: -25 ~ + 75 ° C
Built-in I / O
Digital input and counter: 16 channels
10 pcs. Independent high voltage 15A relays - SPDT (Form C)
Relay spade terminals. COM, NO, NC
Web Server for Browser-based setup and control
No software or device drivers required
XML status and control page make PC applications simple
Can function as a Modbus/TCP slave
On / Off and Pulses
DIN rail Mountable - Open Board
LED Indicates the current relay mode
Ideal for industrisal applications
Power supply: 9 - 28 VDC / 1.5A
UL Approved relays (E197852).
Network-based Digital I/O Module
2 x Power Relay 3 Amp, COM NO, NC
2 x Digital Input Optoisolated 0 - 26VDC
Memory for 50,000 Loggings
Logging of Input, Counter value
Relay state and Volt in
Basic script for advanced flexibility
Send email alarms (up to 8 email addresses)
Static or DHCP IP address
RTC with NTP server synchronization
No software required
XML, Modbus / TCP and Remote Services
On-site updates
Removable terminal connector
Supply voltage: POE or 9 - 28VDC
Controlbyweb I / O module with digital in and relay Out
No programming required
Full control of web browser or XML messages
is also a Modbus / TCP slave
password protected
30vdc , 240vac, 12a relay switch
on / off or pulsed relay states
optically isolated digital input
suitable for monitoring / relation management
Remove-Reloading (peer-to-peer)
Auto-restart
Selectable TCP ports
Removable terminal connector
DIN rail or wall mounting
Power supply: 9-28VDC / 0.5a
Controlbyweb I / O module with digital in and relay Out
No programming required
Full control of web browser or XML messages
is also a Modbus / TCP slave
password protected
30vdc , 240vac, 12a relay switch
on / off or pulsed relay states
optically isolated digital input
suitable for monitoring / relation management
Remove-Reloading (peer-to-peer)
Auto-restart
Selectable TCP ports
Removable terminal connector
DIN rail or wall mounting
Power supply: 9-28VDC / 0.5a
Network-based Digital I/O Module
2 x Power Relay 3 Amp, COM NO, NC
2 x Digital Input Optoisolated 0 - 26VDC
Memory for 50,000 Loggings
Logging of Input, Counter value
Relay state and Volt in
Basic script for advanced flexibility
Send email alarms (up to 8 email addresses)
Static or DHCP IP address
RTC with NTP server synchronization
No software required
XML, Modbus / TCP and Remote Services
On-site updates
Removable terminal connector
Supply voltage: 9 - 28VDC
Web based controller with 8 digital inputs
Digital High is: +4 - +26VDC
8 x digital inputs Opto-isolated
Common ground
200Hz Counter - 24bit
Tasks: 50 Schedule Planned, 50 Conditional, 20 Tuffer Terms
Email Alarms by defined conditions
Supports encrypted e-mail servers such as Gmail
RTC with NTP server synchronization
No software required
Graph (Logged data)
HTTPS / TLS encrypted
Static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Dim: 98 x 78 x 36 mm
Web based controller with 8 digital inputs
Digital High is: +4 - +26VDC
8 x digital inputs Opto-isolated
Common ground
200Hz Counter - 24bit
Tasks: 50 Schedule Planned, 50 Conditional, 20 Tuffer Terms
Email Alarms by defined conditions
Supports encrypted e-mail servers such as Gmail
RTC with NTP server synchronization
No software required
Graph (Logged data)
HTTPS / TLS encrypted
Static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Dim: 98 x 78 x 36 mm
Expansion module for X-400, X-600 Controller
with Daisy Chain for several I/O modules
16 x Dry Spst Form c relay - Signal relay
Relays can be grouped in common
Activation of Relays Can switch individual
16 x digital input - optoisolated, 4 - 28VDC
4 x analog inputs - 12bit, 0 - 5VDC, common gnd
LED Indication - Relay and DI status
Supply voltage: 9 - 28VDC ( Preferably 24VDC)
Dim: 219 x 126 x 50 mm
Weight: 342g
DIN mount
WEB-based data logger for temperature and humidity sensors
Can be programmed to 3 second sampling time
-55 - + 125°C, -40 - + 80°C 0 - 100%rH
4 pcs. 1-Wire bus for 16 sensors, each
Max. 64 pcs. temperature or temperature/humidity sensors
Max. distance to sensors: 180 meters
Tasks: 50 scheduled, 50 Conditional, 20 override
Email alerts, custom (encrypted email servers, such as gmail)
Real-time clock with NTP server synchronization
No software required
Configurable logging
Graph (logged data)
HTTPS/TLS encrypted
Static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtering
On-site is updated
For DIN rail / wall
Supply voltage: PoE or 9 - 28VDC, 134mA
Dimensions: 98 x 78 x 36 mm
WEB-based data logger for temperature and humidity sensors
Can be programmed to 3 second sample time
-55 - + 125°C, -40 - + 80°C 0 - 100%rH
4 pcs. 1-Wire bus for 16 sensors, each
Max. 64 pcs. temperature or temperature/humidity sensors
Max. distance to sensors: 180 meters
Tasks: 50 scheduled, 50 Conditional, 20 override
Email alerts, custom (encrypted email servers, such as gmail)
Real-time clock with NTP server synchronization
No software required
Configurable logging
Graph (logged data)
HTTPS/TLS encrypted
Static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtering
On-site is updated
For DIN rail / wall
Supply voltage: 9 - 28VDC, 134mA
Dimensions: 98 x 78 x 36 mm
Web based controller with I/O, 1-wire bus
4 x digital inputs (Common GND)
1-wire bus, max. 16 sensors (temp / moisture etc.)
Permissions: Administrator, Manager, User
Tasks
50 Scheduled
50 Conditional
16 Automatic Restart
20 Over Rule Terms
E-mail Alarms by defined conditions
Supports encrypted e- Mail servers such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Configurable Logging
Graph (Logged Data)
HTTPS / TLS encrypted
Static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Web based controller with I/O, 1-wire bus
4 x digital inputs (Common GND)
1-wire bus, max. 16 sensors (temp / moisture etc.)
Permissions: Administrator, Manager, User
Tasks
50 Scheduled
50 Conditional
16 Automatic Restart
20 Over Rule Terms
E-mail Alarms by defined conditions
Supports encrypted e- Mail servers such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Configurable Logging
Graph (Logged Data)
HTTPS / TLS encrypted
Static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: PoE or 9 - 28VDC
4 x analog inputs with common GND
input voltage: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
Input current: 4-20mA - 200 Ohm Shunt resistance
2 X digital inputs / outputs: 0 - 5VDC
Digital I/O and Counter set up via the web server
1-wire bus for a maximum of 16 sensors
Temp/moisture/ultrasound, etc.
ermissions: Administrator, Manager , User
Tasks
50 Schedule Scheduled
50 Conditional
20 Torrect Scheduled
Email Alarms Based on Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
Basic script support for advanced flexibility
Logging and graph view
static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
4 x analog inputs with common GND
input voltage: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
Input current: 4-20mA - 200 Ohm Shunt resistance
2 X digital inputs / outputs: 0 - 5VDC
Digital I/O and Counter set up via the web server
1-wire bus for a maximum of 16 sensors
Temp/moisture/ultrasound, etc.
ermissions: Administrator, Manager , User
Tasks
50 Schedule Scheduled
50 Conditional
20 Torrect Scheduled
Email Alarms Based on Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
Basic script support for advanced flexibility
Logging and graph view
static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
Modbus Master Controller for max. 32 Modbus RTU devices
1-wire bus for a maximum of 16 sensors (temp / moisture etc.)
Tasks:
50 schedule planned, 50 conditional
20 Terrul Terms
Email Alarms by defined conditions
Supports encrypted email servers, such as Gmail
RTC with NTP server synchronization
No software required
Configurable logging
Graph (logged data)
HTTPS / TLS encrypted
static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Robust cabinet for DIN rail / wall
Supply voltage: 9 - 28VDC
8 x analog inputs - Sample Rate 25 times per second
8 x input - Single ended: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
input 1 - 4 Can be 4-20mA
Web server for configuration and remote monitoring
Permissions: Administrator, Manager, User
Tasks
50 schedule planned
50 Conditional
20 overroubed
Email Alarms by Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Logging - Graph Presentation
static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Digital temperature sensor with 1-wire interface
Sensor diameter: 5.5mm
Sensor length: 50mm
Cable: 1 meter
3-wire cable: + 5VDC, GND, data
Max distance from feel to controller is 185 meters
IP66
stainless steel sensor
Water detector with normally closed relay output
Supply voltage: 5VDC / 10mA
Relay contact: max. 30VDC/500mA
Red: +5VDC
Black: GND
Green: Relay contact
White: Relay contact
REMEMBER: Relay contact opens when water is removed.
Spare part
Accessories for MFI-Mport. PIR sensor for ceiling mounting
ZigBee modul med 14 indgange
ZigBee modul med 8 indgange
Master, med Ethernet port og 1Kb buffer
Slavemodul med Ethernet til ZIG-MST-E-I
1-wire adapter box for K Thermopler element
acquire K-thermocoupler sensor
adapter with built-in DS18B20 Chip
interface is + 5VDC, GND, data
screw terminal for K-Thermoføler
Spare part
Terminal card with 16 "Open Collector" outputs
DIN mount
for DIO Radio series
Measures: -20 ~ + 60 ° C and 0 ~ 100% RH
Accuracy: ± 0.4 ° C; ± 3.0% RH
LCD display shows the temperature, humidity, dewpoint and
module ID
10 ~ 30 VDC power input
IP66 Waterproof
Data Logger
Memory for temperature and 4,088 humidity records
RS-485 communication interface
DCON or Modbus RTU
Double-lane recognition
Up to 60 fps at 1920 × 1080
Standalone database
IR distance up to 30 m
Day and Night function
Digital I/O (2 in / 2 out)
SD card slot for data
Built-in heater and fan
Recognize vehicles with speeds up to 100 km/h
Powered via POE / 12VDC
IP67 , Defog
31 languages on Web interface
CE, FCC, LVD, RoHS compliant
280 VAC 20 A solid state relay
Flange-mounting
ONLY for AC voltage
280 VAC 120 A solid state relæ til panelmontering
1-axis vibration measurement
Frequency range: 10 Hz to 1K Hz
Amplitude range: ±8g
Data Format:
Acceleration(mg): RMS, Maximum, P-P
Velocity(mm/s): RMS
Top 10 spectrum values(Amplitude/Frequency)
Crest Factor
Supported Modbus RTU Slave protocol
Size: 51 x 30 x 19mm
Supply voltage: 10 - 30VDC
Temp: -25 - +75°C
either 128kb or 2mb buffer
DC 9v/200mA with 3mm DC plug
Baud rate from 50 to 115K
7 or 8 data bits, ODD EVEN or NONE parity
18 Pin male Connector
Single-Mode Fiber (Multi-Mode optional)
1-Channel Duplex Rs485
Point-to-Point or Daisy-Chain (M485-FIBER-SR is needed)
DC input 5V (< 3W)
Operating tempeture: -45 C~+75 C
Up to to 115.2Kbps data rate
Single-Mode Fiber (Multi-Mode optional)
1-Channel Duplex Rs485
Point-to-Point or Daisy-Chain (M485-FIBER-ST is needed)
DC input 5V (< 3W)
Operating tempeture: -45 C~+75 C
Up to to 115.2Kbps data rate
8 isolated digital inputs with 16 bit counter
RS485 interface
-25 ° C ~ + 75 ° C
Display
DIN rail
Screw terminal
ANALOGT INPUT MODUL TIL MODBUS
Mediekonverter fra seriel til optisk fiber
Point til Point transmission
RS232 eller RS422 eller RS485
Op til 40 km med single-mode
ST stik - duplex
Til 9/125my single mode fiber
Reducerer signalinterferens
Beskytter mod elektrisk interferens
Baud rate op til 921,6 kbps
Temperaturområde: -40 til+75°C
Forsyningsspænding: 12 - 48VDC
Mål: 100 x 90 x 22 mm
DIN beslag som tilbehør
DB9 female connector
1200 to 921600 baud
Supply 5 to 24 volts via USB or screw terminals
Built-in WiFi antenna
USB adapter cable included
Module A - Serial for Fiber - Fiber for Serial Link
Automatic RS-485 Directional Control
Optical Fibers Allows Transmission Up to 15 km to B Module
Avoid lightning and EMI / RFI interference
Supports +10 VDC ~ +30 VDC
ESD protection for data line RS-232/422/485
DIN rail mounting
support operating temperatures from -25 ° C ~ +75 ° C
Module B - Serial for Fiber - Fiber for Serial Link
Automatic RS-485 Directional Control
Optical Fibers Allows Transmission Up to 15 km to the A module
avoiding lightning and EMI / RFI interference
Supports +10 VDC ~ +30 VDC
ESD protection for data line RS-232/422/485
DIN rail mounting
support operating temperatures from -25 ° C ~ +75 ° C
Module to Can 2.0a and B
ISO 11898-2 standard
Baudrate 10Kbps for 1M bps
software for setting CAN and RS232 / 422/485
Transparency between RS-232 / 485/422 Via CAN bus
Full duplex on RS-232/422 units are not supported
CAN Bus Baud Rate Configuration
CAN Accept Filter Configuration
CAN 2.0A or 2.0B Specific Choice
RS-232 / 485/422 Baud rate and data file setting
RS-232/485/422 Respond Options
Setting: Normal or pair connection
ICP DAS I-7231-D-G-CR
Serial to HART Convert
Allows 2 pcs. Hart Masters
Point-to-Point or Multi-Drop Hart Mode
Possibility of connecting 15 HART modules
Point-to-point or multi-drop HART mode
for configuration of modules
Isolated COM 1: RS-232 / 422/485
PWR / RUN / ERR INDICATION LED
Built-in Watchdog
4 kV ESD protection
Pico ADC-10 PC data acquisition
8 Potential-free relay outputs - 230Vac / 16 A, 24VDC / 10 A
Relay outputs are individually via HTTPS, SNMP or Command
Startup delay from 0 to 9999 seconds. Adjusted individually
Inrush Delay is set to 1 second
Programmable on / off sequence
Activating relays can be controlled from sensor or inputs
8 channel watchdog via ICMP / TCP Ping
8 signal entrances From NO and NC units, door contacts, etc.
Entrance to sensors Temperature, humidity and air pressure
Messages via e-mail, Sylog and SNMP Trap MQTT
Depending on thresholds for sensor measurement and signal input
LED display for overall power, IP address, sensor data and error reports
Android app and iOS app
DIN bracket
Industrial and IT room monitor unit
1 x RJ45 Ethernet 10/100 Mbps
USB port For USB camera
USB memory for logging, max. 64GB SD
Built-in USB hub
4 x Analog ports for sensors (can be expanded)
2 x Digital input (dry contact)
1 x CAM port (max. 10 sensors, can be expanded)
2 x Relay output
Desktop, Wall, (Option: DIN and 19" brackets as extensions)
Dimensions: 150 x 140 x 28 mm
250 VAC klæberelæ til DIN skinne
250 VAC relæ til DIN skinne
Auto switch relay for ignition 24 V
Incl. cable
Pt100 transmitter from sensor to 4-20mA
Working voltage: 24VDC
Accuracy: +/- o.2% full scale
Temperature range: -50 - +200°C
Dimensions: Ø45 mm
Plastic
Weight: 25g
Clamping: Center hole
Zero point adjustment
Adjustment of amplitude
Pt100 sensor 2 m Cable
100 mm Steel Tips
3.2 mm Diameter
Prototype Map (64 x 70 mm) Expansion module for M485A PC-I
Accessories
Protective cover
for DIO-RXX and DIO-TXX
ARM Cortex - A53 CPU , 1.2 GHz
RAM 1Gb SDRAM
16GB of memory
2 x RS232/422/485
8 x DI and 4 x relay outputs
DC input 9-32V
4G module
OS : Linux Raspbian
User need knowledge of linux and programing
Documentation for DI/O and 4G module
PROFINET / MODBUS konverter Gateway
PROFINET klasse B og RT klasse 1
1 x RJ45
Cyklisk tid: 1ms (min)
Generisk GSDML-fil (version 2.25)
Max længde af input/output data er 512/512 bytes
Understøtter Modbus Master og Slave mode
Understøtter Modbus RTU- og ASCII -format
RS232 or RS422 or RS485
Baud rate for COM1 fra 1,2 til 460,8 kbps
LED-indikatorer
4 kV kontakt ESD-beskyttelse til enhver terminal
Strømforsyning: +10 til +30 VDC
Driftstemperatur: -25 til +75°C
PROFIBUS TO HART Convert, Gateway
4 x HART Canals
Max. 2 pcs. HART Masters
Point-to-Point or Multi-Drop HART Mode
Possibility of connecting 15 HART modules
PWR / RUN / ERR indication LED
Built-in Watchdog
4 kV ESD Protection
Operating temperature -25-75 ℃
for DIN rail mounting
Gateway from Ethernet slave to PROFIBUS master
protocol / hierarchy: DP-V0 Slave
PROFIBUS Speed (Kbps) in 10 step from 9.6 - 12000
speed setting is automatic
Max. Input data length: 240 byte
Max. Output data length: 240 bytes
Address setting: 0 ~ 126 Set by DIP switch or EEPROM
Ethernet protocol: TCP / UDP server / client
Configuration: Web Configuration
The motion sensor light detection, temperature sensor for energy management
Connects energy management, local-lighting control via RS485 port
With powerful built-in relay for simple light activation 250VAC (1500 Watt T8 )
360 ° motion detection - up to 8 m in diameter and 4 meters height
Time delay / Sensitivity is adjustable
temperature sensor, - measuring the room temperature or fire alarm
Relay output to turn on the light via the PIR / light-strength and temperature sensors
RS485 2-wire communication bus
DCON and Modbus RTU protocols
ceiling surface mounted design
Supply voltage: 10 - 30VDC ca. 2W
Dimensions: Ø121 x 52 mm | IP20
Pigtail Fiber Cable
Multi mode
Simplex
1 x FC connector 50 / 125my
Aqua
0.5m
Discount on larger amounts
Network module with digital I / O Korenix JETI / O 6550
Channels: 14/8
Digital inputs: 14 pcs., Logic 0: 0 - 4 V, Logic 1: 5 - 30V
Digital outputs: & nbsp; 8 pcs. Open collector, 5 - 40 V 250mA
Isolation: Optical 2500 VRMS for analog and digital inputs and outputs for the power supply
Magnetic 1500 V from the network interface for the power supply
10/100 Mbit m / RJ45 their connector
Operating temperature: - 25 ° C - 70 ° C
Supports Modbus / TCP, OPC server, SNMP. Software included for configuration
For DIN rail mounting
Supply: 10 - 30 VDC via terminal block, Max 1.92 W
Built-in web server
Web HMI
Supports Modbus TCP and MQTT protocols
2-port Ethernet switch (LAN Bypass) for Daisy-Chain Wiring
Double watchdog
Digital input: 16 channels
Wet contact input
Input high = +10 - 50VDC (ON)
Input low = < +4VDC
Supply voltage: 12 - 48VDC
Temperature: -25 - +75°C
Dimensions: 120 x 97 x 42
Built-in web server
Web HMI
Supports Modbus TCP and MQTT protocols
2-port Ethernet switch (LAN Bypass) for Daisy-Chain Wiring
Double watchdog
Digital input: 16 channels
Dry contact input
Input to Gnd = High (ON)
Input open = Low (OFF)
Supply voltage: 12 - 48VDC
Temperature: -25 - +75°C
Dimensions: 120 x 97 x 42
RS485 Module with 16 digital outputs
16 x digital outputs, Open Collector
Output load: 30VDC / 100mA per Port
Common gnd
voltage: 10 - 30vdc
Your bracket
Compact Modbus / TCP to RTU / ASCII gateway with PoE
not to be programmed
1 x RJ45 10 / 100Mbps
1 x RS485 / 422 (screw terminal)
baud rate up to 115,200 bps
Self-tuner for RS485 / 422
Automatic transmission / reception direction of RS485
IEEE 802.3af - PoE (PD)
Supply voltage u / PoE: 12 - 48VDC 2Watt
Dimensions: 90 x 52 x 27 mm
DIN bracket
Operating temperature: -25 - +75°C
Supports Modbus TCP/UDP master and slave
Supports Modbus RTU/ASCII master and slave
Max. TCP connections (masters) per serial port: 32
1 x RJ45 Ethernet
3 x RS485 ports
Max. 254 notes
Max. baud rate: 115.2kbps
12 - 48VDC / 1.7 Watts
Dimensions: 95 x 52 x 27 mm
Temp: -25 - +75°C
Static IP or DHCP
Web server for configuration (HTTP)
Automatic RS-485 direction control
Terminal blocks
Cost-effective Modbus gateway
Ethernet Gateway for CANopen networks and Modbus RTU
1 x RJ45 10 / 100Mbps
Protocol: Modbus TCP Server
1 x RS232 / RS485 port (non-isolated)
Modbus RTU slave
Baud rate: 1200-115200
1 x CAN port
CANopen
CAN Baud rate: 10K - 1M
Built-in 120 ohm termination
Dimensions: 122 x 72 x 33 mm
Supply voltage : 10 - 30VDC, 2,5Watt
Operating temperature: -25 - + 75 ° C
DIN bracket
Supports M-Bus Standard: EN-13757, CJ / T -188
1 x RJ45 Modbus TCP
1 x M bus for maximum 100 slaves
M-Bus Power limiter
1 X RS232 for firmware update
Modbus TCP / RTU Function code 0x03 and 0x04 To read measurement data
Baud rate: DIP switch to M-Bus and serial port from 300 to 115200 BPS. Standard M-Bus port- Data format: data bit 8, parity straight, stop bit 1
supports up to 100 m bus slaves
m-bus power protection
short circuit protection on M-bus
Firmware updates via serial port
gives PWR, MTX and MRX 3 LED Indicators
Wall Mounting
Dim: 123 x 102 x 40 mm
Supply voltage: 10 - 30VDC
Support input voltage 10 ~ 30VDC
Fully compatible with ISO 11898-2 standard
1 x RJ45 Ethernet interface
2 x CAN bus 9-pole D-sub
Mechanical selection of CAN Bus Baud rate
support for CAN bus ID filter function
Support for CAN Bridge
CAN Bus Monitoring
CAN Baud Rate from 10Kbps to 1Mbps
Modbus TCP Client / Server function Via Configuration
Support for TCP / UDP CAN Pair Connection
Bootloader for firmware updates
Supply voltage: 10 - 30VDC
Operating temperature: -25 to +75°C
Dim: 147 x 107 x 26 mm
Compact Modbus / TCP to RTU / ASCII gateway with PoE
not to be programmed
1 x RJ45 10 / 100Mbps
1 x RS232 / RS485 / RS422 (terminal block)
Choose only one COM port as interface
3-pin RS232 (RX, TX, GND)
baud rate up to 115,200 bps
Self-tuner for RS232
IEEE 802.3af - PoE (PD)
Supply voltage u / PoE: 12 - 48VDC 2Watt
Dimensions: 90 x 52 x 27 mm
DIN bracket
Operating temperature: -25 - +75°C
Compact Modbus / TCP for RTU / ASCII Gateway with PoE
must not be programmed
1 x RJ45 10 / 100Mbps
1 x RS232 (DB9 Han)
Supports Modbus TCP / UDP Master and Slave
Supports Modbus RTU / ASCII Master and Slave
Baud Rate Up to 115,200 BPS
Self-Tuner for RS232
IEEE 802.3af - PoE (PD)
Supply voltage U / Poe: 12 - 48VDC 2Watt
Goal: 90 x 52 x 27 mm
DIN bracket
Operating temperature: -25 - + 75 ° C
Compact Modbus / TCP to RTU / ASCII gateway with PoE
not to be programmed
1 x RJ45 10 / 100Mbps
1 x RS232 (terminal block) - 5-pin
1 x RS485 (terminal block ) - 2-pin
baud rate up to 115,200 bps
Self-tuner for RS232
IEEE 802.3af - PoE (PD)
Supply voltage u / PoE: 12 - 48VDC 2Watt
Dimensions: 90 x 52 x 27 mm
DIN bracket
Operating temperature: -25 - +75°C
Mini vertical level switch / swim switch
Assembly: Vertical
contact output: Direct load
Cable length: 30 cm
Operating temperature: -20 ° C to + 80 ° C
AC voltage Max: 130V < Br> DC voltage Max: 180V
Max current: 700mA
Compact design
Wide adjustment range
DIN Rail mountable 35mm
Thermostat 0 to 60 °C
Snap-Action Contact
Housing plastic, UL 94V-0, light gray
Max. inrush current AC 16 A for 10 seconds
Max. switching capacity NC: 10 A resistive / 2 A inductive @ AC 250 V, NO: 5A resistive / 2A inductive@250V 15A resistive/2A inductive@AC120V DC30W(DC24-72V)
IP20
Dimensions 60 x 33 x 43
RS485 / RS422 / RS232 Master Gateway to Meter-Bus Slaves (sensors, actuators, etc.)
Supports up to 100 Meter-Bus meters (slaves)
MODBUS RTU function codes: 0x03 and 0x04 readdata
Selection of serial port, only one can be selected to be active
Baud rate x 2 (M-bus and COM port can be selected at different speeds)
Baud rate M-bUS: 300-2400 bps
Baud rate COM port: 300-115200 bps
Transparent data - no protocol conversion
M-BUS connection, 2-wire, max. 350meter.
Greater distance up to 5km requires a number M-bus repeaters
Supply voltage: 10 - 30VDC, 1.8 - 12Watt
Dimensions: 122 x 72 x 33 mm
Removable terminal blocks
Operating temperature: -25 - + 60°C
DIN mount
Robust plastic case
RS485 / RS422 / RS232 converter for Meter-Bus meters, actuators, etc.
Supports up to 100 Meter-Bus meters (slaves)
Selecting the serial port, only one can be selected to be active
2 x Baud rate (M-bus and COM port can be selected at different speeds)
Baud rate: 300 to 115,200 bps
Transparant data - no protocol conversion
M-bus connection is 2-wire , max. 350meter.
larger distance up to 5km requires a number of M-bus repeaters
Supply voltage: 10 - 30VDC, 1.8 - 12Watt
Dimensions: 122 x 72 x 33 mm | Removable terminal blocks
Operating temperature: -25 - + 75 ° C
DIN bracket
Robust plastic housing
Protocol converter from M-BUS devices to PC/PLC which is Modbus Master
Up to 20 M-BUS units (meters)
RS485 Modbus interface for Modbus master
Free setup software
Supply voltage: 18 - 35VDC, 15 - 21VAC
Max. power consumption: 4 Watt
Baud rate: 1200 - 115,200 baud
Galvanic isolation
Temperature: -40 - +70°C
Dimensions: 71 x 60 x 60 mm
Built-in Web server
Logical functions with IF-THEN-ELSE setting
IF-THEN-ELSE for simple set of conditions
No more programming. Just click and finished
Supports I / O, counter, timer, calendar, e-mail, rules
Data Logger and data files supported rewind feature
Modbus TCP / RTU protocol for SCADA software seamless integration
I/O-Board XW with inputs and outputs
Supports I-7000 Remote I / O modules (up to 16)
Supports Modbus RTU slave units (up to 10)
SNTP time synchronization supported
Support SMS (GSM: Quad-band 850/900/1800/1900 MHz)
Supply voltage: 12 - 48VDC
The logger / controller with socket for internal I / O expansion bus (eg. Relay module)
is programmed with simple logic functions
IF-THEN-ELSE, AND and OR simplifies the setup
supports SNMP, SMTP , FTP, Modbus RTU and DCON
Ethernet 10/100 / 1000Mbit
setup via the integrated Web server
1 x RS232 ports
1 x RS485 ports
Supply voltage: 12 - 48VDC
Liquid depth measurement with RS485 interface
measuring depth: 0 - 12 meters
Operating temperature: -30 - + 140 ° C
House: PC / PBT, Cream transducer
Supply voltage: 8 - 24VDC < Br> Objective: Tip Ø 5cm
setup with RST-3002 programming module
The indoor light-gauge, temperature and humidity sensor 3 in 1
For energy optimization and building automation systems
Measuring range of illumination: 0 to 20,000 lux
Temperature Range: -20 to + 60 ° C
humidity Measuring range: 0 to 100% RH
Supports DCON and Modbus RTU / TCP protocols
Supports MQTT protocol Ethernet interface
With RS485 / RJ45 Ethernet communications interface
Relay output - 6 Amp @ 250VAC
Power supply: PoE and 10 - 48VDC, ca. 2 Watt
Operating temperature: 0 - + 75 ° C
web configuration and firmware update via Ethernet
Ceiling Mounting
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I/O module, counter, timer, email
Modbus/TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet
8 x Power relay output, COM NO
Relay switch: 30VDC, 250VAC 5A, only resistive load
Supply voltage: PoE or 12 - 48VDC / 5.5Watt
1 x RJ45 - 10/100 Base-TX Ethernet
Can be powered from a PoE
Integrated Web Server Setup
Logical functions with IF-THEN-ELSE
Rules, I / O, CGI counter, Timer, etc.
Email setup via Web browser
Modbus / TCP Protocol to 6 x Digital input (Wet Contact - external voltage for High)
Digital input has 16 bits counter
6 x Relay Power Output: 5A at 30VDC / 250VAC
Power over Ethernet (PoE) or an external DC power supply
Supply voltage: PoE or 12 - 48VDC / 5Watt
temperature range -25 ° C ~ + 75 DEG C
Intelligent Controller with Webserver
Logical functions such as: IF-THEN-ELSE
No programming. Just pick, click and finished
Supports: I / O module, counter, timer, email
Modbus / TCP protocol to SCADA software seamless integration
IEEE 802.3af compliant Power over Ethernet ( PoE)
1 x RJ45 - 10 / 100Mbit Ethernet
7 x Temperature sensor inputs (differential)
2/3-wire Pt100, Pt1000, Ni120, CU100, Cu1000
A/I resolution: 16bit
12 samples per second (Total)
Individual sensor configuration
Power supply: PoE or 12 - 48VDC / 4.5Watt